Safety
Generators produce carbon monoxide when running. Carbon monoxide is a deadly, invisible, and odorless gas. Carbon monoxide from generators kills about 70 people each year in the US. Do not ever operate a generator in a house, garage, or any connected structure, even if the windows and doors are open.
Fuel
Fuel Types
Most home backup generators run on gasoline, propane, and/or natural gas.
You can buy a generator that is designed to burn one, two, or all three of these fuel types. Generators that are designed to burn only one or two fuel types can often be modified to burn other types of fuel. Each type of fuel has its pros and cons:
Gasoline
Pros:
- Readily available at gas stations (if the stations have power)
- Relatively easy to transport / handle in plastic or metal tanks
Cons:
- Goes bad rapidly in storage. Storage life can be extended with stabilizers, but not indefinitely.
- Tends to gum/clog carburetors if not drained after generator use / prior to storage.
- Is dangerous to store in large quantities; doing so may be against insurance and/or mortgage contracts.
Propane
Pros:
- Unlimited storage life
- Safe to store, even in large quantities
- Does not gum/clog carburetors
- Readily available in small tanks at gas stations / liquor stores / etc
Cons:
- Reduces maximum generator output by 5-10% (compared to gasoline)
- Small tanks may provide insufficient gas pressure in low temperatures, especially when generator is operating at high load
- Moderately large tanks may be cumbersome to transport to refilling stations. Larger tanks require on-site refilling via truck.
Natural Gas
Pros:
- Delivered by pipeline, no effort required to refuel/refill
- Unlimited and reliable fuel supply during normal conditions and many emergency situations
Cons:
- Reduces maximum generator output by ~20% (compared to gasoline)
- Fuel supply could be unavailable during emergency conditions (earthquake, energy shortages, etc)
Connection to House Electrical System
Never attempt to connect a generator to a house's electrical system without the use of a transfer switch or interlock kit. Doing so is dangerous and could kill or injure you or a utility worker.
It is best to use a 240 V generator if you plan to connect the generator to a house's electrical system.
The least expensive safe and legal way to connect a generator to a house's electrical system is with a power inlet and generator interlock on the main breaker box.
Use at least 10 ga wire for a 30 A connection, at least 8 ga wire for a 40 A connection, and at least 6 ga wire for a 50 A connection. Thicker gauges may be required depending on wire length and type.
Sizing
Most electric motors draw a large "startup surge" of power for a second or two when switched on compared to the amount of power they draw once they are up and running steadily. This can pose a challenge in sizing a generator.
The startup surge from central air conditioners can be significantly reduced with the use of a soft-start device.
Electrically commutated / inverter-based electric motors generally do not draw a startup surge, and you should not attempt to connect a soft-start device to such motors.
Inverter vs. Conventional Generators
Inverter generators use less fuel than conventional generators, especially when not running near full capacity.
The engine in a conventional generator has to run at a constant speed (usually 3000 or 3600 RPM) in order to maintain the 50 or 60 Hz AC output frequency. Inverter generator engines can run at lower RPMs when under lower loads, resulting in quieter operation than conventional generators.
Many inverter generators can be connected to each other in parallel in order to double their power output capacity. Conventional residential generators typically cannot be paralleled.
Miscellaneous Info
Most portable generators do not have oil filters. Using a magnetic dipstick and drain plug on such engines will help keep metal shavings out of the lubrication system.
Open frame generators are louder than closed frame, but are typically lighter and cheaper.
Closed frame generators are quieter than open frame generators, but typically run hotter.