I’m renovating a two-storey chalet bungalow in the UK, with a separate outdoor office, and planning a fairly comprehensive KNX installation. This is my first full KNX project, so I’d really appreciate any top tips, lessons learned or regrets from people who have done something similar.
I completed a basic KNX course with one of the UK training companies, which was excellent and extremely helpful. I have also built a small KNX and DALI test rig so I can test components properly before committing to the whole house. I have purchased ETS and am quite comfortable with it - it isn't as bad as people make out but is quite powerful!
1. The DALI rabbit hole
My original plan was straightforward: use KNX for on/off control throughout, with central switching actuators.
I then read about soft-on and soft-off dimming, which sounds very plush. After reading more on these forums, I convinced myself that tunable white would be excellent in most living areas, meaning DT8 fixtures and drivers would be desirable.
Other users here give the impression that phase-cut dimming is effectively dead, while constant-current LED drivers are the technically correct and future-proof solution.
However, when I started trying to specify actual products in the UK, the theory on this became much less convincing.
Tunable white downlights (that aren't just a selection switch on the light) seem almost non-existent outside commercial and office lighting. Constant-current residential fittings also seem surprisingly difficult to find. Most of the available options appear to be 9–12W downlights, which are too powerful for many of our rooms and would require fewer fittings at wider spacing.
I can buy separate LED engines and lamp holders, but then I am effectively assembling the luminaires myself and need to deal with compatibility, housings, cooling, fire protection and certification across the entire house. That feels like a considerable faff compared with buying a tested, fire-rated residential fitting.
My tests so far
For my test setup, I bought:
- An ARC-LED dim-to-warm GU10 bulb
- Two ARC-LED Tru-Colour 9W, 200mA LED engines
- Two Osram OT DALI 15/220-240/350 CS constant-current drivers
- A Sunricher SR-2303SAC-HP DALI phase-cut dimmer
The results were not in line with users comments on this forum.
The £8 dim-to-warm GU10 works extremely well with the Sunricher phase-cut dimmer. There is no noticeable buzzing or flicker, and it dims almost all the way down to off, with a smooth transition back on. Given everything I had read about phase-cut LEDs, that was quite a surprise. My partner really liked the performance of these too. I have ordered some of ARC-LED's normal dimmable GU10 bulbs to see if they also perform as well.
The Osram constant-current drivers only dimmed to around 1%. Ok - I should have seen that in their specs. More concerningly, when switched off they sometimes produce what sounds like an initial capacitor-charging whine followed by a continuous, very high-pitched noise. Sometimes it is clearly audible and sometimes it is not.
The approximate costs were:
- GU10 bulb: £8
- LED engines: £18 each
- Sunricher phase-cut DALI dimmer: £16
- Osram constant-current DALI driver: £17 each
People often recommend eldoLED constant-current drivers. An appropriate driver seem to be around £40–£50 each on eBay and roughly twice that new. Cheaper EldoLED models seem to have a cap of 40V and I cannot find suitable LED engines that fall under this cap.
That means the DALI/constant-current route could easily cost £50 or more per spotlight. Each constant-current spotlight appears to need its own driver, whereas one phase-cut channel can control several GU10 fittings.
Am I misunderstanding the normal residential approach here? I've heard people say to buy ordinary downlights and toss the driver but then you are back to figuring out the current and other ratings of the led engine that is left and validating it yourself.
2. DALI wiring versus long-term maintainability
The wiring case for DALI is attractive. I could run five-core cable around the house and achieve flexible control without returning every individual lighting zone to the KNX cabinet. I am sure my electrician would like this too.
However, I am becoming concerned about fault-finding and future replacement. A GU10 lamp is likely to remain easy to source. A matching constant-current driver and LED engine, with the correct current, voltage range, physical dimensions, dimming behaviour and colour characteristics, feels much more bespoke - especially given my challenges locating what I need today!
There is also the question of what happens in 20 or 30 years when individual components are discontinued.
With centrally wired KNX lighting, someone could eventually remove the KNX actuators and replace them with contactors, conventional relays or ordinary switching arrangements in the plant room. It might not be elegant, but the fixed wiring could still be reused.
If DALI control is built into UK walls and ceilings without individual switched returns, converting it back to conventional control seems much more difficult. Furthermore, with drivers located near the fixtures then I need to consider maintainability and either have to have them accessible in the ceiling or in a wall box which adds another thing to think about.
At my scale, the cost difference between DALI and direct KNX dimming does not appear huge. I expect approximately 20–25 dimming channels, so KNX dimming actuators seems comparable with buying numerous DALI drivers plus a KNX-DALI gateway provided I buy sensibly.
I am currently leaning towards:
- Central KNX switching and dimming
- Conventional replaceable phase-cut lamps or complete residential fittings
- DALI only where it provides a clear benefit, which at this stage is nowhere.
- Possibly dim-to-warm bulbs in a limited number of important rooms rather than throughout the house
Would anyone who has completed a similar installation now choose differently?
3. Simple switching
The 20–25 channels above relate only to dimmable lighting. I have also bought several reasonably priced KNX switching actuators on eBay for simple or less important lighting circuits.
Are there any particular lighting loads where people regret using switching rather than dimming, or vice versa?
4. Wired 230V blinds
The next issue is blinds. I want straightforward wired 230V blind motors controlled through KNX actuators.
Most UK websites seem to push Lutron, proprietary remotes, wifi, wireless controls or Zigbee. It is surprisingly difficult to find sensibly priced wired blind motors without being directed towards expensive complete automation packages.
A basic wired motor feels as though it should be the cheapest and simplest option.
Which UK suppliers or motor manufacturers should I be looking at? Are Somfy WT motors still the obvious choice, or are there better-value alternatives? Does anyone have a good supplier?
5. Conduit
Is anyone using significant amounts of conduit in a UK residential installation?
I can see the future-proofing benefit, particularly for KNX bus cable, window contacts, blinds, data and specialist lighting. However, I am conscious that extensive conduit could add cost and complexity without necessarily making later cable replacement as easy as imagined.
For those who installed it:
- Where was it genuinely useful?
- Where was it wasted?
- What conduit sizes did you use?
- Did you run it to every switch position, window and ceiling location, or only strategic routes?
6. One central cabinet or two?
I had originally planned one large central control cabinet containing the KNX power supplies, actuators, protective devices and terminal blocks. However, the plant room is becoming crowded with MVHR, heating, server rack and this KNX cabinet.
The house layout may make two cabinets at opposing ends possible for reducing cable lengths and the number of large cable bundles crossing the building. I will probably also install a small consumer cabinet in the garden office for those loads/actuators/switches.
For people who have installed centralised KNX lighting in a similar-sized house, would you favour one cabinet or two? Did splitting the system make maintenance easier, or simply duplicate equipment and consume more space?
7. Temperature sensors
I am considering using remote temperature probes connected to KNX binary inputs or devices with analogue temperature inputs. We will have polished concrete on the ground floor with temperature sensors embedded in there.
I assume ceiling height near windows would be a poor representation of room temperature, particularly with solar gain, cold glazing and stratification. Have people placed sensors behind ventilated wall plates at switch height, used dedicated KNX room controllers, or concealed them elsewhere? Has anyone put them at the entrance to MVHR duct returns?
8. Window and door contacts
I would also like wired contacts on the new windows and doors, feeding local KNX binary inputs such as the Theben TA 8 S.
Has anyone found surface-mounted contacts that:
- Do not require drilling into the window frames and potentially voiding the warranty
- Are small and reasonably discreet
- Work reliably with modern aluminium windows and doors
- Do not look completely awful
I would prefer concealed contacts, but only if the window manufacturer is willing to incorporate or approve them. We will be using a Cortizo system which has a eurogroove for these sensors on the window but no holes in the frame for wires.
9. Spotlights, task lighting and ambient lighting
What balance have people used between ceiling spotlights, task lighting and ambient lighting?
Our architect dislikes LED strips and thinks they often look tacky. Their preference is for conventional lamps around the house, which I can control from KNX switched or dimmed socket outlets.
I partly agree, especially where strips are visible or create the “glowing ceiling slot” effect. However, concealed linear lighting can also provide useful indirect light when designed properly.
Did anyone install too many downlights or strips and later wish they had used more wall lights, lamps or indirect lighting? Conversely, did anyone rely too heavily on decorative lamps and find the rooms impractical?
10. Multi-core lighting cables
To make the centralised wiring more efficient, I am considering using suitable five-core cable to carry three separately switched or dimmed line conductors with a shared neutral and CPC, but only where the circuits, protective devices, isolation arrangements, dimmer outputs and manufacturer requirements make that permissible.
Has anyone used this approach extensively with KNX dimming actuators in a UK installation?
Are there particular dimmer types or fault conditions that make shared-neutral arrangements problematic? I will have the final design checked and installed by the electrician, but I would like to establish the architecture before first fix.
The main question
Am I missing a major advantage of using DALI and constant-current drivers throughout a house?
DALI sounds excellent in principle: simpler cabling, individual addressing, regrouping, diagnostics and DT8 tunable-white control. But in practice, I am finding:
- Limited choice of suitable residential DT8 fittings
- Poor availability of lower-power constant-current downlights
- High per-fitting driver costs
- Questions about driver noise and minimum dimming levels
- Additional compatibility and fire-rating considerations
- Greater dependency on particular LED engines and drivers
- More difficult conversion to conventional controls in future
- Little obvious cost saving at only 20–25 dimmed zones
Meanwhile, a decent dim-to-warm GU10 on a DALI phase-cut dimmer has performed far better than I expected.
For anyone who has completed a similar UK KNX renovation:
- Would you choose KNX-only lighting, KNX plus DALI, or a mixture?
- What practical benefit does DALI deliver after commissioning?
- Is individual luminaire addressing genuinely useful in a house?
- Did you use tunable white as much as expected?
- Which fittings and drivers have proved reliable and replaceable?
- What would you change if doing the installation again?
- What should I include at first fix that is difficult or impossible to add later?
- What did you spend money on that turned out to be unnecessary?
I am not opposed to DALI and would happily use it where it earns its place. I am simply trying to avoid creating an expensive, bespoke lighting system when straightforward KNX dimming and replaceable lamps may be more practical over the life of the house.
All top tips, product recommendations, wiring lessons and regrets would be very welcome.