r/KNX • • Oct 28 '20

New to KNX? Here's where to start

25 Upvotes

KNX Basics

Are you curious about KNX but not sure what it is or where to start? Download this short 24 page free booklet that explains all of KNX's fundamental concepts and everything you need to know to decide whether KNX is right for you. It's written using simple terminology so that anyone with technical leanings can understand the technology.

Next Steps

If you want to know more, the Basic Course and Advanced Course books for €5 each will take you the rest of the way and are worth every penny.

https://my.knx.org/en/shop/books

Keep Going

Additional resources can be found in our Wiki:

https://www.reddit.com/r/KNX/wiki/tutorials


r/KNX • • 15h ago

Black Friday week 2026: 50% off 11 ETS Apps

5 Upvotes

Got this newsletter in my mailbox yesterday: this week (23-29 Nov 2026) there's a promo campaign for Black Friday, offering 50% off the regular price for the following 11 ETS apps:

  • Extended Copy
  • Replace Device
  • Device Compare
  • Project Tracing
  • Labels
  • EIBlib/IP
  • Split & Merge
  • ETS6 Device Reader
  • My Device Templates
  • Project Access Assistant
  • Bulk Linker

This doesn't cover ETS itself, just the apps for it.

The newsletter does not directly publish a universal voucher code, instead offers a link/QR code where I have to log in with my own account and then confirm my participation in the campaign, which adds a voucher code in my account. It might be that the link is unique for each newsletter recipient, and so is the voucher code, so I won't share that code which might be usable just once.

However - if you have not subscribed to the newsletter, try to access my.knx.org and log in; you might get a pop-up/overlay announcing this event and giving you the option to participate by clicking a button, and that way you'll still get the discount voucher. Let the community know if this works.

I'm zealously avoiding newsletters as a general rule, and hhhhaaaaaate opt-out approaches. KNX is among the very few I've made an exception for, and so far they haven't broken my trust or annoyed me with too frequent messages, just with the promotions they have running. If you're also privacy obsessed focused 😄 you might want to consider subscribing not to miss out on savings.


r/KNX • • 11h ago

Tips & Tricks How and where did you installiere your KNX weather station?

2 Upvotes

I‘m currently planning to install a weather station on a hipped roof and would appreciate any suggestions regarding the mounting


r/KNX • • 1d ago

KNX doorbell

6 Upvotes

I built my electrical installation with KNX and am now looking for a doorbell system with an intercom. Does anyone have experience with a product that combines very well with KNX?


r/KNX • • 1d ago

Tips & Tricks First full KNX project (new-build villa), experienced in home automation, new to KNX as a pro. Advice welcome

3 Upvotes

(Quick note: English isn't my first language, so I used an AI to help me write this post. The project, the choices and the questions are my own, and I've proofread everything carefully.)

Hi all,

I run a small home automation business in Morocco (engineering background in embedded systems). Until now I've mostly done retrofits with Home Assistant(for automation) + Zigbee + apple home kit (for customers control), fully local, apart home kit control. I've just landed my first full KNX job on a new build and I want to do it properly, as a professional.

The project:
Villa on 2 floors, one of 11 identical units in the same development. Roughly:

- ~34 lighting circuits, ~9 dimmable (spots, pendants, magnetic track, LED strips)

- 16 wired roller shutters, ~22 control locations

- Irrigation (4 zones) + pool pump, 4 ducted AC units via Home Assistant

- KNX/IP to Home Assistant for supervision; everything must still work from the wall if the server is down

Hardware is EAE (what my local distributor carries): PS640, IPI200, RCU actuators, UI108 inputs.

Plastering starts in ~3 weeks, so the wiring plan has to be frozen now.

My questions:

  1. Conventional pushbuttons star-wired to inputs in the panel (up to ~25 m), with KNX keypads only at the 3 busiest spots: good idea? Any pitfalls with long input runs?
  2. Dimming mixed loads (230 V spots, 24 V strips, track): DALI-2, universal dimmers or 0-10 V?
  3. Any real-world feedback on EAE (reliability, ETS apps, support)?
  4. Two distribution boards: all actuators in one with long star runs, or split per floor?
  5. What do you wish you'd known on your first KNX job?

Thanks in advance for your help and advices.


r/KNX • • 6d ago

vKNX - Simulate and Program virtual installation through ETS

Thumbnail gallery
49 Upvotes

Hello fellow knx-people.

I'm a Tutor from Denmark, and teach electrician apprentinces at a technical school. My biggest problem with the students is they have no way of training ETS/KNX outside the school, after 4 weeks with me, they are back to work at companies that do not do KNX, and their certifications gotten from school, while still valid - are pretty much useless after a year or two.

So I have built a windows program that simulates a KNX installation, like a cross-breed between KNX Virtual and KNX Simulator. I called it vKNX.

The point of the program is, you import your custom ".knxprod" devices in ETS, programm them and set group adresses as you would in normal installation, and download to your vKNX enviroment. There you need to press programming button on each device to adress it, and configurate. Then you can try it out, and see it work on the ETS Group Monitor.

There are also a floor planning, where you can add a floor plan and put your outputs etc on the floorplan and see it react.

Right now I have 18 different devices, the ones I especially proud of is my logic controller - with in-built 16 inputs and outputs, that inside vKNX can be connected through logic gates, for more complex tasks. (inspired by ABB's ABA/S 1.2.1 - logic controller - Claude AI and I used it only for inspiration). And secure devices - (I have push button and switch actuator) - which can be set to KNX Secure with commisioning codes etc.

Line couplers work, with their filter tables - that was a hard one to do, but it works.

vKNX - will forever be open-source and is made to get more people into KNX world - hopefully also people who want to stay trained.

It's still in the early stages, I only been gathering information and doing research for about 6 months, and vibecoding it for about 2 months only. But it's where I want to take a step back, and gather as much feedback as possible - to build it further.

Here is a link to my GitHub: https://github.com/MrDahl/vKNX

The program isn't signed, so Microsoft will screen it - So it is up to you to install it.

The .knxprod products you need to import in ETS yourself.


r/KNX • • 7d ago

Use Atios or 1Home for an existing KNX installation

4 Upvotes

I have a small apartment where there was a very old Gira homeserver, controlling around 30 lights in different rooms, 3 o them with dimmers, but the rest is just on/off. There is nothing else on the system except lights. The original installer is long out of business, and the homeserver died. I don't have any ETS files or anything like that. Is there anyway I can connect Atios, 1Home or a Gira X1 and it will just know what lights are on the system? If I buy these myself and connect it, will it work, or do these devices need a professional installer to activate them? The homeserver uses a USB port to connect, but when I look at the X1 etc, they have a two wire connector.

There was a Gira touchscreen but that died years ago, so I have been using the Gira App to control the lights, if that makes any difference.


r/KNX • • 7d ago

Tips & Tricks ABB i-bus KNX motion censor issues

1 Upvotes

The parking motion censor is not working which is connected with the KNX module. The censor is blinking constantly when there is a motion near it but the light seems to be switched on even when there is no motion. Can someone explain the connection and workings of the i-bus KNX motion censor ?


r/KNX • • 7d ago

KNX Anbindung

2 Upvotes

Hello, I have a KNX control system and a Basalte Core Mini server. I would like to connect this setup to a display that I can also use for other functions, such as a calendar, camera feed, etc. Is there an off-the-shelf solution for this? Alternatively, is it possible to connect it to an Echo Show? Thanks for your help! Best regards


r/KNX • • 8d ago

Older KNX devices for simple dimming

2 Upvotes

KNX rookie here.. Some old IHC lighting controls broke down the other day in a place where I help out with basically all things technical. The ceiling lights use the older low energy bulbs and are controlled using a 1-10V signal. I have searched for a suitable control system and KNX seems to fit the bill. It is indeed overkill for one conference type room with four groups of fixtures (perhaps 24 fixtures in total), but as I have plans to modernize more stuff in the building, I wanted to learn a bit about KNX and would like to use this project as a starting point.

I plan to purchase cheap KNX stuff on eBay or similar just to get started. As I need four 1-10V channels and switched 230 V AC supply to the fixtures in order to put the light out completely, I figured a pair of these this could do (leaving me two channels extra):

Hager TK030 EIB KNX switching/dimming actuator control unit 1-10V 3x

For input, would these work?:

Schneider Electric MTN6528 Push Button, 8-gang KNX (or the MTN6524 4-gang)

I guess I'll be needing a 29 V DC SELV power supply too.

The manual for the Schneider buttons claim "The application can only be operated with ETS3.". Will they be able to run alongside more modern KNX stuff if we expand? I guess they could sit on their own KNX TP/EIB bus with a KNX router in between if needed. As I understand it, KNX TP and EIB are interchangeable, right?

So, that leaves the programming of these devices, introducing the biggest downside to KNX in my opinion, RTS. €200 for the lite version will be more than the rest of the gear! Will RTS 6 be able to program these old dimmers and buttons?

Do I have any options for programming these except RTS? I'd of course like the buttons and dimmers/actuators to work in stand alone mode, so they only talk to each other. I guess Home Assistant etc. cannot program them into doing this, or am I mistaken?


r/KNX • • 10d ago

open-source CLI + MCP server that lets Claude/ChatGPT read, audit and program a KNX installation - bussard

Thumbnail gallery
27 Upvotes

I'd like to share bussard: an open-source command-line tool (Windows, Linux, macOS) for KNX. It exposes everything over MCP so that Claude, ChatGPT etc. can read, audit and modify an installation.

Why? Instead of clicking through ETS menus, I want to change our installation with a sentence like:

"There's a door contact on the patio door, and we have a weather station. When the door opens, the outdoor light should turn on; when it closes, off again – but only when it's dark."

You install bussard and connect it via MCP to e.g. Claude Desktop. Claude can then find the right devices, create group addresses and links, set parameters and program the devices over the bus.

What it is not: I'm not trying to rebuild ETS, and there is no configuration UI (there is a bus visualisation, but that's mostly for my own debugging). It's aimed at smaller installations. I'm a software developer, not an integrator, so I don't know the workflows of large projects.

"What if the LLM messes things up?" That was the part I cared about most:

  • Every change can be undone. bussard stores a version per change.
  • The MCP server can be started read-only, so the LLM can e.g. look for errors but can't change anything.
  • All changes are planned and shown first, then applied explicitly.

Status: I use bussard on our own installation (Jung, Gira, Theben, ...). The project is still young, so please try it in read-only mode first.

Background: I've been a software developer in open source for 10 years. Over the last few months I've seen a lot of different approaches to building an ETS alternative, and I find them really inspiring. I wanted to try something that works a bit differently.

I'd love your feedback, especially: would you let something like this near your installation, and what would it take?


r/KNX • • 11d ago

Whole-house UK KNX renovation: am I missing something with DALI, constant-current lighting and future-proofing?

8 Upvotes

I’m renovating a two-storey chalet bungalow in the UK, with a separate outdoor office, and planning a fairly comprehensive KNX installation. This is my first full KNX project, so I’d really appreciate any top tips, lessons learned or regrets from people who have done something similar.

I completed a basic KNX course with one of the UK training companies, which was excellent and extremely helpful. I have also built a small KNX and DALI test rig so I can test components properly before committing to the whole house. I have purchased ETS and am quite comfortable with it - it isn't as bad as people make out but is quite powerful!

1. The DALI rabbit hole

My original plan was straightforward: use KNX for on/off control throughout, with central switching actuators.

I then read about soft-on and soft-off dimming, which sounds very plush. After reading more on these forums, I convinced myself that tunable white would be excellent in most living areas, meaning DT8 fixtures and drivers would be desirable.

Other users here give the impression that phase-cut dimming is effectively dead, while constant-current LED drivers are the technically correct and future-proof solution.

However, when I started trying to specify actual products in the UK, the theory on this became much less convincing.

Tunable white downlights (that aren't just a selection switch on the light) seem almost non-existent outside commercial and office lighting. Constant-current residential fittings also seem surprisingly difficult to find. Most of the available options appear to be 9–12W downlights, which are too powerful for many of our rooms and would require fewer fittings at wider spacing.

I can buy separate LED engines and lamp holders, but then I am effectively assembling the luminaires myself and need to deal with compatibility, housings, cooling, fire protection and certification across the entire house. That feels like a considerable faff compared with buying a tested, fire-rated residential fitting.

My tests so far

For my test setup, I bought:

  • An ARC-LED dim-to-warm GU10 bulb
  • Two ARC-LED Tru-Colour 9W, 200mA LED engines
  • Two Osram OT DALI 15/220-240/350 CS constant-current drivers
  • A Sunricher SR-2303SAC-HP DALI phase-cut dimmer

The results were not in line with users comments on this forum.

The £8 dim-to-warm GU10 works extremely well with the Sunricher phase-cut dimmer. There is no noticeable buzzing or flicker, and it dims almost all the way down to off, with a smooth transition back on. Given everything I had read about phase-cut LEDs, that was quite a surprise. My partner really liked the performance of these too. I have ordered some of ARC-LED's normal dimmable GU10 bulbs to see if they also perform as well.

The Osram constant-current drivers only dimmed to around 1%. Ok - I should have seen that in their specs. More concerningly, when switched off they sometimes produce what sounds like an initial capacitor-charging whine followed by a continuous, very high-pitched noise. Sometimes it is clearly audible and sometimes it is not.

The approximate costs were:

  • GU10 bulb: £8
  • LED engines: £18 each
  • Sunricher phase-cut DALI dimmer: £16
  • Osram constant-current DALI driver: £17 each

People often recommend eldoLED constant-current drivers. An appropriate driver seem to be around £40–£50 each on eBay and roughly twice that new. Cheaper EldoLED models seem to have a cap of 40V and I cannot find suitable LED engines that fall under this cap.

That means the DALI/constant-current route could easily cost £50 or more per spotlight. Each constant-current spotlight appears to need its own driver, whereas one phase-cut channel can control several GU10 fittings.

Am I misunderstanding the normal residential approach here? I've heard people say to buy ordinary downlights and toss the driver but then you are back to figuring out the current and other ratings of the led engine that is left and validating it yourself.

2. DALI wiring versus long-term maintainability

The wiring case for DALI is attractive. I could run five-core cable around the house and achieve flexible control without returning every individual lighting zone to the KNX cabinet. I am sure my electrician would like this too.

However, I am becoming concerned about fault-finding and future replacement. A GU10 lamp is likely to remain easy to source. A matching constant-current driver and LED engine, with the correct current, voltage range, physical dimensions, dimming behaviour and colour characteristics, feels much more bespoke - especially given my challenges locating what I need today!

There is also the question of what happens in 20 or 30 years when individual components are discontinued.

With centrally wired KNX lighting, someone could eventually remove the KNX actuators and replace them with contactors, conventional relays or ordinary switching arrangements in the plant room. It might not be elegant, but the fixed wiring could still be reused.

If DALI control is built into UK walls and ceilings without individual switched returns, converting it back to conventional control seems much more difficult. Furthermore, with drivers located near the fixtures then I need to consider maintainability and either have to have them accessible in the ceiling or in a wall box which adds another thing to think about.

At my scale, the cost difference between DALI and direct KNX dimming does not appear huge. I expect approximately 20–25 dimming channels, so KNX dimming actuators seems comparable with buying numerous DALI drivers plus a KNX-DALI gateway provided I buy sensibly.

I am currently leaning towards:

  • Central KNX switching and dimming
  • Conventional replaceable phase-cut lamps or complete residential fittings
  • DALI only where it provides a clear benefit, which at this stage is nowhere.
  • Possibly dim-to-warm bulbs in a limited number of important rooms rather than throughout the house

Would anyone who has completed a similar installation now choose differently?

3. Simple switching

The 20–25 channels above relate only to dimmable lighting. I have also bought several reasonably priced KNX switching actuators on eBay for simple or less important lighting circuits.

Are there any particular lighting loads where people regret using switching rather than dimming, or vice versa?

4. Wired 230V blinds

The next issue is blinds. I want straightforward wired 230V blind motors controlled through KNX actuators.

Most UK websites seem to push Lutron, proprietary remotes, wifi, wireless controls or Zigbee. It is surprisingly difficult to find sensibly priced wired blind motors without being directed towards expensive complete automation packages.

A basic wired motor feels as though it should be the cheapest and simplest option.

Which UK suppliers or motor manufacturers should I be looking at? Are Somfy WT motors still the obvious choice, or are there better-value alternatives? Does anyone have a good supplier?

5. Conduit

Is anyone using significant amounts of conduit in a UK residential installation?

I can see the future-proofing benefit, particularly for KNX bus cable, window contacts, blinds, data and specialist lighting. However, I am conscious that extensive conduit could add cost and complexity without necessarily making later cable replacement as easy as imagined.

For those who installed it:

  • Where was it genuinely useful?
  • Where was it wasted?
  • What conduit sizes did you use?
  • Did you run it to every switch position, window and ceiling location, or only strategic routes?

6. One central cabinet or two?

I had originally planned one large central control cabinet containing the KNX power supplies, actuators, protective devices and terminal blocks. However, the plant room is becoming crowded with MVHR, heating, server rack and this KNX cabinet.

The house layout may make two cabinets at opposing ends possible for reducing cable lengths and the number of large cable bundles crossing the building. I will probably also install a small consumer cabinet in the garden office for those loads/actuators/switches.

For people who have installed centralised KNX lighting in a similar-sized house, would you favour one cabinet or two? Did splitting the system make maintenance easier, or simply duplicate equipment and consume more space?

7. Temperature sensors

I am considering using remote temperature probes connected to KNX binary inputs or devices with analogue temperature inputs. We will have polished concrete on the ground floor with temperature sensors embedded in there.

I assume ceiling height near windows would be a poor representation of room temperature, particularly with solar gain, cold glazing and stratification. Have people placed sensors behind ventilated wall plates at switch height, used dedicated KNX room controllers, or concealed them elsewhere? Has anyone put them at the entrance to MVHR duct returns?

8. Window and door contacts

I would also like wired contacts on the new windows and doors, feeding local KNX binary inputs such as the Theben TA 8 S.

Has anyone found surface-mounted contacts that:

  • Do not require drilling into the window frames and potentially voiding the warranty
  • Are small and reasonably discreet
  • Work reliably with modern aluminium windows and doors
  • Do not look completely awful

I would prefer concealed contacts, but only if the window manufacturer is willing to incorporate or approve them. We will be using a Cortizo system which has a eurogroove for these sensors on the window but no holes in the frame for wires.

9. Spotlights, task lighting and ambient lighting

What balance have people used between ceiling spotlights, task lighting and ambient lighting?

Our architect dislikes LED strips and thinks they often look tacky. Their preference is for conventional lamps around the house, which I can control from KNX switched or dimmed socket outlets.

I partly agree, especially where strips are visible or create the “glowing ceiling slot” effect. However, concealed linear lighting can also provide useful indirect light when designed properly.

Did anyone install too many downlights or strips and later wish they had used more wall lights, lamps or indirect lighting? Conversely, did anyone rely too heavily on decorative lamps and find the rooms impractical?

10. Multi-core lighting cables

To make the centralised wiring more efficient, I am considering using suitable five-core cable to carry three separately switched or dimmed line conductors with a shared neutral and CPC, but only where the circuits, protective devices, isolation arrangements, dimmer outputs and manufacturer requirements make that permissible.

Has anyone used this approach extensively with KNX dimming actuators in a UK installation?

Are there particular dimmer types or fault conditions that make shared-neutral arrangements problematic? I will have the final design checked and installed by the electrician, but I would like to establish the architecture before first fix.

The main question

Am I missing a major advantage of using DALI and constant-current drivers throughout a house?

DALI sounds excellent in principle: simpler cabling, individual addressing, regrouping, diagnostics and DT8 tunable-white control. But in practice, I am finding:

  • Limited choice of suitable residential DT8 fittings
  • Poor availability of lower-power constant-current downlights
  • High per-fitting driver costs
  • Questions about driver noise and minimum dimming levels
  • Additional compatibility and fire-rating considerations
  • Greater dependency on particular LED engines and drivers
  • More difficult conversion to conventional controls in future
  • Little obvious cost saving at only 20–25 dimmed zones

Meanwhile, a decent dim-to-warm GU10 on a DALI phase-cut dimmer has performed far better than I expected.

For anyone who has completed a similar UK KNX renovation:

  1. Would you choose KNX-only lighting, KNX plus DALI, or a mixture?
  2. What practical benefit does DALI deliver after commissioning?
  3. Is individual luminaire addressing genuinely useful in a house?
  4. Did you use tunable white as much as expected?
  5. Which fittings and drivers have proved reliable and replaceable?
  6. What would you change if doing the installation again?
  7. What should I include at first fix that is difficult or impossible to add later?
  8. What did you spend money on that turned out to be unnecessary?

I am not opposed to DALI and would happily use it where it earns its place. I am simply trying to avoid creating an expensive, bespoke lighting system when straightforward KNX dimming and replaceable lamps may be more practical over the life of the house.

All top tips, product recommendations, wiring lessons and regrets would be very welcome.


r/KNX • • 11d ago

Atios SmartCore (DALI-2) users: does it have its own scheduler/astro clock, or does everything run from Home Assistant?

4 Upvotes

I’m planning a DALI-2 lighting system for a villa (about 170 DALI devices across 5 lines). One option is one Atios SmartCore (ADE-R12) per DALI line, connected to Home Assistant over Matter. Before I commit, I’d like to hear from anyone who has actually used one.

  1. Schedules on the device: Can the SmartCore run time-based or sunset/sunrise (astro) schedules on its own? Or do all schedules have to come from Home Assistant, so they stop working if HA is down?
  2. What Matter exposes to HA: Do DALI groups show up as single lights, or only individual devices? Do DALI-2 occupancy sensors (part 303) come through as occupancy entities?
  3. Button events: Can HA see DALI-2 push-button presses (short, long, double) as triggers, or only the light state after the press?
  4. Third-party couplers: Does the SmartCore accept non-Atios DALI-2 push-button couplers, e.g. Lunatone DALI-2 MC, or only its own AFD-B4?
  5. Several units: Has anyone run 3–5 SmartCores in one HA instance over Matter? Any problems with stability, commissioning, or firmware updates?
  6. Heat: Has anyone had trouble in warm installs? The rated maximum ambient is 45 °C.

For comparison, the other option I’m considering is a Lunatone DALI-2 IoT4 gateway with the official HA integration. Experience with either one is welcome.


r/KNX • • 13d ago

Lighting for Residential project

8 Upvotes

We are considering a KNX bus-based domotica system.

Have some few questions :

  1. What is best suited for residential homes between dim-to-warm and tunable lights.
  2. Do dim-to-warm light fixtures exist with a color temperature range between 1800-4500K ?
  3. Can these dim-to-warm lights using a DALI DT8 driver, be adjusted for brightness and temperature separately ?
  4. Where is the best place to buy these light fixtures in Northern Europe region ? We have a lighting fixtures quote of 30K EUR from a light designer for a 3-bedroom house of 240sq meter area. We believe it’s very pricey.

Thank you!


r/KNX • • 16d ago

Looking for small KNX programming projects to gain experience

6 Upvotes

Hi everyone!
I’m looking for small KNX programming projects to improve my skills and gain more practical experience with ETS6.
My idea is simple:
You send me your ETS6 project file and explain what needs to be programmed or changed.
I work on the programming remotely.
Once finished, I send the updated project file back to you.
I’m mainly interested in gaining experience with different KNX devices, manufacturers and real-world applications.
I’m happy to do this for free, as my main goal is to learn and further develop my skills.
If anyone has a small project or could use some help with KNX programming, feel free to send me a message!
Thanks!


r/KNX • • 18d ago

Getting KNX-DALI HCL to play nice with DTW

2 Upvotes

I have a stupid first-world problem. My system has a human-centric lighting set-up so there is a ramp-up curve in the morning and ram-down in the evening. Everything is fine by itself, except the following problem: I have dim-to-warm lights. Now the way they work is that when you lower the brightness, you lower the color temperature. Unfortunately, the reverse is also true: if you set the color temperature to some value - it adjusts the brightness accordingly.

Makes sense in theory, but in practice the lights are always on because the HCL signal is transmitted regularly. Which means that at any point at night, HCL transmits, say, 2700K, every single DTW light sees this and sets its brightness to whatever matches. As you may have guessed, there is no color value that sets DTW lights to no brightness, i.e., off.

How can I fix this situation? Essentially what I want is something like "respond to HCL signals only when you're on", if that's possible.


r/KNX • • 19d ago

First fix sanity check: KNX + DALI new build (UK). Anything I'd regret not pulling?

7 Upvotes

Planning the first fix for a two-storey new build (UK) and want to make sure nothing needs re-pulling later. Equipment choices can change; cables can't.

I have an electrical and controls background, planning to commission the system. My electrician has installed DALI in industrial projects in the past, not in domestic.

**Lighting (all DALI)**
- Lighting circuits as radials per RCBO (L, N, E), looped to driver locations at ceiling hatches in each room, with a DALI pair (2 × 1.5 mm²) run alongside (5c).
- 24 V / 48 V runs from each driver to its fittings: 1.5–2.5 mm², under ~10–15 m.
- 1-2 DALI loop per floor back to the board.

**KNX**
- Green KNX cable (2×2×0.8) to every switch position, presence sensor and spare position. Legs star out from the board, daisy-chain within each area.
- No mains at switch positions; 47 mm boxes.
- Bus drops to all switch positions, including both bedsides in each bedroom; spare coiled drops at the back door and other "maybe" spots; KNX bus + Cat6 to each possible wall-panel position.

**Other**
- 3-core + E to each future blind position at the window head.
- Cat6 star-wired to a central cabinet; outdoor Cat6 + control cable in duct to the gate.
- Detached garage: KNX burial cable in its own duct (plus SWA and data in separate ducts).

**Questions**

  1. Is a DALI pair alongside the lighting radials enough, or would you also pull a spare pair or KNX to each driver location?
  2. Any reason to run lighting as home runs to the board as a fallback, rather than radials to the driver locations? Perhaps remove DALI and staying within knx..
  3. Spare cores or cable types you wish you'd pulled at first fix?
  4. Anything above that you'd do differently?
  5. Are there any schematics of something like this out there so we can check our design?

r/KNX • • 23d ago

Swisstoggel KNX 1.0 is out: the full version of my local-only KNX app is now on Google Play

19 Upvotes

Hi r/KNX,

some of you may remember my post about the beta of Swisstoggel KNX. The beta phase is over: thanks to everyone who signed up, tested on their own installations and sent feedback. A lot of it went straight into the app, and version 1.0 is now publicly available on Google Play.

Quick recap for everyone else: I got tired of KNX visualisations that need a server, a cloud account or a subscription. So I built Swisstoggel KNX, an Android app that connects straight to your KNX IP interface or IP router on the home network.

New since the beta: draw your floor plan by hand and see your house as a 3D dollhouse with live lights and blinds, plus many fixes after a full review of every function.

What it does:

  • Tunneling over UDP and TCP, routing via multicast, KNX IP Secure and Data Secure (keys from your .knxkeys, they never leave the device)
  • ETS import (.knxproj from ETS4/5/6, also password protected): rooms and functions are suggested, you just review
  • Lights (dim, RGB/RGBW, tunable white), blinds with slats, heating with setpoint and mode, fans, scenes, sensors, text displays
  • Floor plans per storey: import a PDF/image of your electrical plan, or draw rooms by hand, then view the house as a 3D dollhouse where lit lamps glow
  • Group monitor with readable values, send telegrams, status check that tells you which addresses don't answer
  • App scenes on widgets, voice and NFC stickers; wall tablet mode
  • Only shows what the bus confirmed, no guessed state

Price: free to install with a full demo home, setup of your whole installation and the first 5 functions you operate. The full version is a one-time in-app purchase (29 USD / 29 EUR / 29 CHF), no subscription, no ads, no tracking.

Remote access is deliberately not built in: use your own VPN.

Play Store: https://play.google.com/store/apps/details?id=ch.swisstoggel.home

I'm looking forward to your feedback: what you like, what bugs you, and what you'd like to see next. Happy to answer any questions in the comments!


r/KNX • • 24d ago

I built another open-source KNX tool. Meet Tinkerbus and please help me find what breaks.

6 Upvotes

Hey everyone,

I’ve been working on Tinkerbus, a desktop app for working with KNX installations. A small personal project. Well, it was supposed to stay small. You know how that goes.

I’m aware I’m not the first person to look at KNX and think, “Surely I can build a tool for this.” So, no grand announcement that I’ve reinvented ETS. I’ve built something, some parts work on real hardware, and now I’d like to find out where it falls over on somebody else’s installation.

Tinkerbus is open source, MIT licensed, and independent of the KNX Association - not affiliated or endorsed. KNX and ETS are their trademarks.

What works so far

  • Opening, editing and saving ETS 6 .knxproj files, including password-protected ones. Devices, rooms, floors, group addresses with CSV import/export, group object links, parameters, undo/redo, project comparison and printable reports.
  • Telegram monitoring and recording over KNXnet/IP, with UDP and TCP tunnelling. Names come from your project; values are decoded by data type. Watching is passive.
  • Line scans and device information, compared against the devices in your project. Because what’s in the file and what’s actually installed are not always quite the same thing.
  • Full and partial application downloads, with a check first, a backup of device memory and confirmation each time.
  • Five command-line tools sharing the same code: knxproj, knxprobe, knxdownload, knxprogram and knxcap.

There are Windows and Linux builds, plus a Nix flake for NixOS:

nix run git+https://git.tinkerbus.org/tinkerbus/tinkerbus

Now, before we get carried away

This is pre-1.0 software, not an ETS replacement. No commissioning workflows, plug-ins or licence handling. It does not need or use ETS.

Also:

  • No KNX IP Secure. No ETS 4/5 projects yet. One thing at a time.
  • Opening edited files again in ETS is not verified. ETS signs project files, and after Tinkerbus edits one, that signature no longer matches. ETS 6 may warn or refuse to open it. Use “Save as” and keep your original. This is not the place to be economical with backups.
  • Programming support is broader than the hardware testing. Of the 32 mask versions in ETS 6.4, 26 are covered. Full loads are hardware-verified for five: 0x0021, 0x0705, 0x07B0, 0x091A and 0x0012. Another 21 load like a tested mask but are still untried, so the app warns you. The remaining six are refused. Details are in the docs.

Programming a device changes its memory. Sending is off until you enable it. Writes require a check, a backup and a typed confirmation. Routers and couplers can only be written from the command line.

Please start with a device you can recover and keep backups of your projects. Preferably not the device responsible for all the lights just before dinner. No warranty.

About the AI bit

I developed this with AI assistance and tested device programming on real hardware. I’m mentioning that openly, not presenting it as a quality certificate. The source and tests are in the repository - you can have a look and decide for yourself.

What I’d like from you

For a start, read-only testing would already be a big help:

  • Open a project, compare files, export a report or watch the bus. Tell me what breaks or doesn’t make sense.
  • If you have a device with a mask outside the verified list, a report from the app would help me extend coverage.
  • Tell me which ETS 6 feature you’d miss most. Better to ask now than spend three weekends building the wrong thing.

And if you’ve built or tried something similar: what worked, what didn’t, and where did it get painful? No need for me to step into every pothole personally.

Links

One more thing for Windows users: the files are signed with a project CA that Windows doesn’t trust by default. You’ll see “Unknown publisher” and SmartScreen warnings. The download page explains how to verify the signature and checksums.

Anyway, enough talking. Have a look if this sounds useful. Bug reports, honest feedback and stories from earlier attempts are all welcome.

Thanks!


r/KNX • • 24d ago

Tips & Tricks An hour on KNX weather stations with an award-winning integrator (German video, the English AI dub works well)

Thumbnail youtube.com
6 Upvotes

Disclaimer first: this is Elsner Elektronik, a German KNX manufacturer, so the usual bias applies.

Weather stations have led to some really good discussions here, so this might be useful for some of you. Thomas Lübbeke of CASAIO, whose project won the Smart Home Award Europe at this year’s KNX Awards, invited us over to go into the topic properly.

We talked for about an hour: how to choose a station for the building (number of façades, simple brightness thresholds vs. the real sun position, when GPS is worth it), the three wind measurement principles and where each one fits, and the mounting mistakes we keep seeing in service.

It’s in German, but you can watch it in English:

  1. Open the video on YouTube (browser or app).
  2. Click the gear icon. In the app, tap the video first, then the gear.
  3. Go to “Audio track” and choose English.

Depending on your language settings, YouTube may already play the English version automatically. It’s an AI dub, so a few technical terms come out a bit odd, but it’s very watchable. If you’d rather hear the original voices, turn on subtitles and use auto-translate to English.

If you’d handle something in there differently on site, tell us. And what would you want covered in a follow-up?


r/KNX • • 24d ago

IPAS Largho R10 LCD

1 Upvotes

Hello
Does anyone have a project with an old Largho R10 LCD from IPAS?
PN 60601-112-16
I found on the web some projects that have all the old panels
With the Contrattempo I haven’t any problem but with the Largho I downloaded the program but the buttons don’t send any GA thus they are programmed to sent bits
The LCD works fine and the temp changes


r/KNX • • 28d ago

Akuvox intercom with Gira G1

2 Upvotes

Hi there.

Has anyone ever used an Akuvox intercom station with the Gira G1’s

Thanks


r/KNX • • 28d ago

Gira 4 55 Plus - how far does the proximity sensing go?

3 Upvotes

I'm looking into purchasing the Gira 4 55 Plus - wondering if anyone has these and want to give their opinion and maybe test how far proximity sensing goes?


r/KNX • • 29d ago

Monthly Show Us Your Box! Post a photo of your cleanest (or messiest) cabinets

5 Upvotes

There is nothing quite like a well-organized KNX distribution board. Whether you use dedicated terminal blocks for every core or wire directly into the actuators, the way a rack is dressed says a lot about the integrator.

Post a photo of a project you are proud of, or even a nightmare cabinet you inherited that you are currently trying to fix.

Are you a fan of using massive trunking to hide the slack, or do you prefer the look of exposed, perfectly combed looms tied with velcro? Or do you choose chaos?

Show us your box! (SFW only plz)