r/TreeClimbing • • 4d ago

A video from last week's close call

Enable HLS to view with audio, or disable this notification

You can read the full story in the weekly incident/close call thread.

This was a large job involving removing around 30 mature poplars between residential properties and a primary line, plus these two smaller ones. This was a new (to us) contract climber with "12" years experience. This was the first of six major incidents of the day for him.

Friendly reminder that as resi arborists our minimum approach distance (MAD) is 10'. Before this was put into place electrical contact killed more arborists than anything else

*Our safety standards are written in the blood of our colleagues.*

32 Upvotes

13 comments sorted by

2

u/Optimal_Yoghurt_4163 13h ago

Can you please elaborate - is this particular risk more about tree contacting electricity, which then goes to the worker - or is it ‘lines drag the pole or tree, that affects worker’ ? And is this wet/ice dependent - is the conductivity of the tree a thing? Thank you.

1

u/ArborealLife 12h ago

Sure.

Tree climbing is one of the most dangerous civilian careers there is. But the thing is, that risk comes from hazards. And hazards can be identified and mitigated through best practices.

Electrical contact used to kill more climbers than anything else. That was the inspiration for the ANSI Z133 standards, which outlined best practices for mitigating hazards and making climbing safer. 

So, that's basically the story here. Our best practices mandate a MAD (minimum approach distance) of 10' for lines under 50kV (I believe these lines were around 25 kV, but I'm not entirely sure). Nothing should come closer than 10': not the tree, not a rope, not the climber. A tree within 10' is not safe to climb by a residential arborist.

Is the tree still safe to climb and work on? Of course. On this particular project we had a CUA (certified utility arborist) come out and clear the trees back from the lines so we could work on them.

You only have to look at the insulators on the poles to know how small the arcing potential is. These lines aren't going to arc 10', they aren't going to arc 1'. But i this case we have direct contact 🫪

So why the dramatic MAD? Because it keeps us safe and provides a margin for error. I have personally, more than once in my career, fucked up around lines and had branches enter the MAD. That safety margin kept me alive.

What would have the consequence here possibly have been? It absolutely could have grounded through the stem -> climber -> tree -> ground and killed him. It could have damaged the infrastructure requiring expensive repairs. It could have shorted out the lines and blown the fuse a few hundred feed away, knocking out power to the entire community. Which of these would be acceptable?

The climber here exhibited extremely poor judgement multiple times in his first day, and was asked not to come back.

1

u/Optimal_Yoghurt_4163 11h ago

thanks for the details! Somehow I forgot the tree (stem) has water in it, regardless of the weather.

3

u/maddestdog89 4d ago

10 feet? Even with ESI training? I’m only cutting to 12 ft clearance most of the time 😅💁

5

u/ArborealLife 4d ago

As per ANSI Z133-2026: an unqualified arborist has a MAD of 10' for 50 kV and under.

The full chart is on page 11.

5

u/FossilOcelot1991 4d ago

I swear I can feel my bladder when I get within 15’ on those main lines. I don’t get when guys do shit like this.

1

u/maddestdog89 3d ago

Oh, for unqualified, gotcha. You do enough clearance work and you realise they are actually quite durable haha. I’ve personally only ever had one thing hit the lines.

11

u/Brushdragger9000 4d ago

Lost a friend very early into my career to an accident involving power lines, Gotta take the minimum approach serious.
Hopefully buddy learns that before he gets sent into the next dimension doing some stupid shit near the lines.

7

u/mustachlegend88 4d ago

As a utility arborist power lines are fucking terrifying and so many guys dont seem to understand that.

2

u/skisuphill 3d ago

Agreed. Even being cleared to be well within the approach distance of an unqualified utility arborist, I hate doing it. People do not pay enough respect to live lines

6

u/Strange_Ad_5871 4d ago

He’s a “contract climber” that was dumb as fuck. Yeesh. I’d say you’re done right then and there.

2

u/Zstman87 3d ago

Climb higher…smaller tops=smaller problems. Also, contract climber near the wires? Must not have been a job hired out by the utility.

1

u/SomeGreenThumb 3d ago

Living on the edge!!