Memory Scan Freeze & MCU Reset Issue Report
Device Information
Model: AnyTone AT-778UV II VOX
Hardware: V2.0 (VOX version)
Serial Number: 1077253380167
Firmware Versions
- RF FW: V1.10
- RF CPU: V1.11
- LCD FW: V1.10
- LCD CPU: V1.11
- MODE: 02
Radios Tested
The issue has been reproduced on two different AnyTone AT-778UV II VOX V2.0 radios purchased from the same AliExpress seller.
Both units show the same behaviour.
Power Supply
Power configuration:
- 230V AC mains
- 12V / 10A regulated AC/DC power supply
- Cigarette lighter adapter cable
Displayed voltage during operation:
The same power supply setup was previously used successfully with another AT-778UV II unit.
A power supply problem appears unlikely.
Programming Methods Tested
The issue has been reproduced after programming with:
- Official AnyTone CPS v3.01
- CHIRP
- Manual programming directly from the radio keypad
Multiple factory resets and complete power disconnections were performed.
USB Communication Tests
Tests performed:
The problem remained unchanged.
USB driver, USB port and COM port are unlikely causes.
Memory Configurations Tested
Tested configurations:
- PMR channels only
- PMR + VHF
- PMR + VHF + UHF
- PMR + VHF + UHF + repeater memories
The issue occurs with different memory layouts.
Scan Tests
Memory Scan (MR)
The issue is consistently reproduced during Memory Scan.
Tested:
Display modes tested:
- Channel Name display
- Frequency display
The issue occurs regardless of these settings.
Observed freeze times:
- ~1 minute
- ~9 minutes
- ~20 minutes
- ~25 minutes
- ~27 minutes
- ~50 minutes
One earlier test exceeded one hour before freezing.
VFO Scan Test
VFO Scan was tested without using memory channels.
Results:
- One initial VFO scan test appeared to freeze after approximately 30 minutes.
- This behaviour was not reproduced.
- A new VFO Scan test completed successfully for 2 hours and 10 minutes without any scan issue.
Current conclusion:
- VFO Scan appears stable.
- The freeze issue is significantly more reproducible during Memory Scan (MR).
This indicates that the main problem is likely related to memory channel scan management rather than the general scan engine.
MCU Reset Issue After Long Operation
After completing the successful VFO Scan test (2h10):
A factory reset was initiated.
The radio became stuck on:
"Reset MCU please wait"
A complete power disconnection was required.
After reconnecting power:
- The radio restarted normally.
- The factory reset had actually been completed successfully.
This behaviour has been observed multiple times.
The reset operation appears to complete internally, but the user interface remains frozen and does not finish the displayed reset procedure.
Failure Behaviour During Scan Freeze
When Memory Scan freezes:
The radio does not completely crash.
Still working:
- Menu access
- Menu navigation
- Settings modification
- Backlight
- FUNC key
- Programmable keys P1-P6
- VFO mode
- Frequency tuning in VFO
Not working:
- Memory scan
- Memory channel selection
- Channel change in MR mode
The radio remains locked on the last scanned memory channel.
The affected channel changes each time.
Examples:
- PMR12
- PMR14
- UHF04
- Other memory channels
No specific frequency appears responsible.
Restart Behaviour
After some freezes:
- The radio remains stuck on the welcome screen after restart.
- Complete power disconnection is required.
After reconnecting power, the radio starts normally again.
Current Technical Assessment
The issue has been reproduced:
- On two different radios.
- After factory reset.
- With CPS and CHIRP.
- With manual programming.
- After USB driver update.
- With different USB and COM ports.
- With multiple memory configurations.
- With CO and TO Memory Scan.
- With different display modes.
The issue does not appear related to:
- Programming software
- USB communication
- Specific frequency
- Specific memory channel
- Display mode
- Scan delay setting
Current evidence points mainly to:
Firmware issue affecting Memory Scan (MR) management.
Possible causes:
- Memory Scan task failure.
- Memory channel indexing problem.
- Firmware state corruption after repeated scan cycles.
- MCU task synchronization issue.
- Possible firmware issue affecting reset/display synchronization.
Request to AnyTone
Could you please confirm:
- If this Memory Scan freeze issue is known on AT-778UV II VOX V2.0.
- If newer firmware versions are available.
- If a beta or engineering firmware can be provided for testing.
Available for investigation:
- CPS programming files
- CHIRP files
- Videos
- Detailed reproduction procedure
Video: