r/Chempros • • 21m ago

Computational Fast, memory efficient atomistic model, with multiple level of theories. Try it on your laptop or GPU.

0 Upvotes

Github repo: https://github.com/iatecoding/mena-lab

The download and start of the application should be easy, two commands and you should be ready to run simulations on the webapp it opens, with a user friendly interface, using your machine compute. It is optimized for Macbook laptops, but runs at decent speed on GPUs, I hope you like this and find it useful for your workflows or experiments.

I trained this myself after multiple iterations starting from an architecture that worked well on chess engines, it excels in memory efficiency and speed, but this doesn't mean the experiments are unreliable or with high error rates. Clearly there could be bugs, I am open to feedbacks or questions.


r/Chempros • • 1h ago

Moved from paper notebooks to a free ELN (eLabFTW/Chemotion) in an industry lab?

0 Upvotes

Has anyone moved from paper notebooks to a free ELN like eLabFTW or Chemotion in an industry or regulated lab? Did people actually use it, how much IT support did it need, and did QA accept it?


r/Chempros • • 1d ago

Fmoc deprotection and coupling reaction

0 Upvotes

I am dealibg with the Fmoc deprotection and coupling reaction in solution phase
Should I deprotect the Fmoc and isolate the unprotected amine before coupling with another amino acid using HATU and DIPEA?
Because when I did not isolate it, my yield is very bad and I mostly saw the DEA-fulvene adduct in my reaction (I used DEA to deprotect Fmoc).


r/Chempros • • 1d ago

Trace Nitrogen Analyzer for Alcohol/Water Mixture

3 Upvotes

Does anyone have experience working with a PAC ElemeNtS, Elementar Trace SN, or Nittoseiko NSX-5000? I am looking for a trace nitrogen analyzer with chemiluminescent detector to analyze alcohol/water mixtures (10%-80% organic) with <20ppm nitrogen. Any recommendations or issue on one of these analyzers? How is the accuracy, repeatability and stability? Many thanks.


r/Chempros • • 3d ago

Organic Suggestions for a stubborn crown ether synthesis

9 Upvotes

I'm an organic chemist in industry and recently my company became interested in a very specific class of crown ethers for further applications, namely derivatives of (+)-18-crown-6-2,3,11,12-tetracarboxylic acid. To make this, you hydrolyze the corresponding tetraamide. Making the tetraamide itself requires macrocyclizing N,N,N',N'-tetramethyl tartardiamide with diethylene glycol ditosylate in a Williamson crown ether synthesis.

I have attempted this macrocyclization every which way and I still keep getting zero percent yield despite lit procedures saying I should be getting something like 25% (low but usable). The procedure I have been attempting to follow is:

It then goes on to say it was recrystallized from acetone. Instead, what I get at this stage is not a pale yellow solid but some weird oil that has the wrong UV-vis spectrum and the wrong mass by LC-MS. Initially I thought maybe my old bottle of DMSO was the problem so I ordered anhydrous but it's the same story.

When I start adding the diamide to the hydride slurry, initially it goes well but upon warming to room temp after those two hours I get this extremely gelatinous foam that clogs up my stir bar. Then when I add the ditosylate, I was surprised to see a giant amount of foam kicked up by the addition, which I thought was weird since there should definitely be no gas evolution at this point. And it's the same story for DMF and DMAc.

Has anyone had any experience with crown ether syntheses or any of these polyanionic macrocyclizations? Any advice would be helpful. My initial thought is that I have no desired product because not all of my diol is deprotonated due to the gel-induced retardation.


r/Chempros • • 3d ago

Problems with an Agilent 1260 infinity salting out from mobile phase

4 Upvotes

I’m working with an Agilent 1260 infinity series at work and the pumps and lines salt out at least every other week if not more. The lab I’m in runs QaQc for manufacturing and the plant makes a ton of different products that don’t all get tested using that instrument so it sits idle for a couple days or up to a week at a time depending on production. The method set up on the instrument uses a 0.2% phosphoric solution in water and when a series of runs is completed a 1 hour flush is always added to the shutdown but it’s no help, the next time you go to use the instrument it over pressures and you need to take the next 20-30 minutes feathering the purge valve slowly trying to break through the salt buildup. The pump assembly currently doesn’t the peristaltic pump required to run a seal wash for the seal wash supports that are currently installed on the instrument and I wonder if that could be part of the problem. Does anyone out there know if it would lessen that salt buildup if the seal supports were swapped out to a standard set, or would it be more worth it to see if Agilent sells an upgrade kit for a 1260 infinity series that allows for the installation of a seal wash pump and if anyone knows of this upgrade if you also happen to know that part number it would be greatly appreciated. Any suggestions are appreciated though :)

Edit: I was definitely blaming the wrong mobile phase for the salting, this instrument also handles a 0.1M sodium phosphate solution that is definitely responsible, sorry for not noticing that before


r/Chempros • • 3d ago

Isoprene disposal

0 Upvotes

I have 100 ml of isoprene i need to get rid off. Im nervous to add it to general organic waste because of polymerisation or peroxide formation.

What to do?


r/Chempros • • 3d ago

Organic Mono-Protection of Resorcinols

8 Upvotes

Hi everyone, I am a P.h.d. student in organic chemistry and one of the issues I am dealing with is the desymmetrization of Methyl 3,5-dihydroxy benzoate (methyl ester of resorcylic acid). I need just one of the two phenolic hydroxyls to be protected with a base resistant PG. on reaxys everything has low yields (33% mostly) except some patents (which I didn't manage to replicate). Does anyone have a method or suggestions for this kind of reaction? Or am I stuck with a maximal theoretical yield of 50%?

Thanks in advance 😄


r/Chempros • • 4d ago

Losartan Assay - unstable baseline - what went wrong? :(

Thumbnail gallery
1 Upvotes

r/Chempros • • 4d ago

"Need help troubleshooting viscosity issues during xanthan gum nanoparticle fabrication"

0 Upvotes

Hi, just want to know about the solution of the network formation after adding NaOH along with a salt, it forms a green jelly like network, why is it happening and how to dissolve this network in the solution and either this jelly typed network is necessary for the formation of NPs.... and if it's not necessary and need to dissolve ot completely, then how to do this... please let me know if anyone has done his/ her work with is gum. Regards.


r/Chempros • • 4d ago

2 mL GC vials without markings?

4 Upvotes

By coincidence, I'm not only a chemist, but also a mineral collector. Some of my specimens are tiny (millimeter size). I think it's a nice idea to store them in 2 mL GC vials. Those vials are durable, cheap and strong. For visiblity, it would be better if there wouldn't be markings on the outside (the white scale with 0.5 - 1 - 1.5 mL). I've never seen them in 2 mL, only in 4 mL.

Do they exist? Has someone ever seen them?


r/Chempros • • 4d ago

Analytical Vendors for standalone interferometers for FTIR?

4 Upvotes

Does anyone know of vendors that sell standalone IR interferometers for FTIR spectroscopy? I basically want a box where I can send in my IR light, set scan parameters, and get out the interfered light along with the reference laser signal. It seems that all of the instrument vendors only sell complete instruments, and the search results are flooded with companies that make IR imaging cameras that are generally single wavelength or not in the mid-IR region.

I realize this is kind of a strange niche. I'm scoping out a proposal that would use a separate IR source and detector setup so buying a full instrument is a waste of money, but I'd also rather not build the interferometer myself if I can help it since I'm not an optics expert.


r/Chempros • • 4d ago

Disposal / destruction of magnesium turnings

9 Upvotes

I have about 500 grams of magnesium turnings that I need to get rid of. I'm trying to donate it to another company, but if I can't find a donor I need another solution:

  1. Destroy it with dilute acid
  2. Toss it in a chemical waste bin for solids

Given the quantity, destruction is super annoying and tossing it in the chemical solid waste super tempting. But I'm worried it burns a bit too well 😅 What would you do?


r/Chempros • • 4d ago

Academic chemists: what’s the biggest bottleneck in your lab right now?

0 Upvotes

Curious what actually costs academic chem labs the most time and money these days. Is it fighting for NMR or mass spec time, waiting on a shared instrument that’s down, purifications that eat whole days, ordering delays, solvent and waste costs, processing data, or something else entirely?

I’m a student researcher digging into this, and I put together a short survey (about 5 minutes, confidential) for grad students, postdocs, lab managers, techs, and PIs in academic labs:

https://forms.gle/7ETRtHHa9cXYUW3p6

Happy to hear answers in the comments too, even just a one-liner. What’s the thing that slows you down the most?


r/Chempros • • 4d ago

ICP OES help

0 Upvotes

So I have the Avio 550 Max running sample for an Enviormental company. The conc in sample units will not show. All the information is there in place and the units are correct and in place. Send help lol


r/Chempros • • 4d ago

Help obtaining great STEM images.

3 Upvotes

Hello!

We have a Thermo Apreo 2S SEM and STEM is our most used imaging method of nanoparticles for size and morphology. Recently, we had to have an FSE onsite after we saw some drift that was too extreme to image with. He did some things, and upon leaving sent an email with the following recommendations:

  1. Allow system to pump down to mid or low e-4Pa before imaging
  2. To minimize image drift on STEM samples, after finding area of interest, allow sample site to sit 30min -1 hour before making images.

Number 1 makes total sense, but the second point he made wasn't shown or conveyed to me by either of our two application engineers that trained me. We use the system for classes - imaging nanoparticles synthesized in inorganic labs and bacteriophages in biochemistry labs, so the waiting for almost an hour is going to be tough. Furthermore, we know we have some contamination somewhere as we can see the carbon block appear on our sample as the beam sits.

I was curious what everyone else does to get really good STEM images? Of course, when I emailed folks that I was going to be trained and would like them to provide samples for said training, not a soul got back to me.

Right now, if the sample is metallic nanoparticles, I have people use our plasma cleaner that we have (it is not one that can be on the microscope). For organic type samples that won't survive the plasma cleaner, people just let them dry naturally. I have purchased a desiccator that can have a vacuum drawn on it and have been pushing people to use it.

I have plenty of Lee-Miesel Ag nanoparticles I can put on a grid to practice with.

Thanks to anyone willing to share their experience/expertise!


r/Chempros • • 5d ago

Oxygen intrusion

4 Upvotes

Hi all - I run an ETV attached to an ICP-OES. The ETV is destroying graphite parts faster than it should. The vendor says oxygen is getting into the system somewhere. I've checked everything I can for leaks. The only thing left is to check the gas lines for oxygen to see where it's coming from. I've messaged several companies, but I can't find a handheld meter that can read oxygen levels in an argon stream. I need it to read down to 5ppm. Any ideas?


r/Chempros • • 5d ago

Guidance/Suggestions regarding a simple dye adsorption experiment.

Thumbnail reddit.com
1 Upvotes

r/Chempros • • 6d ago

Organic How to prepare for industry interviews ( final year PhD student)

30 Upvotes

Hi all, I am a final PhD student and am currently thinking about my next career move. I want to apply for entry level industrial positions ( process or medchem maybe) and I want to slowly start refreshing my general organic chemistry knowledge. From talking with people who have gone on that route, it seems that the interviews for these positions involve a technical interview, some sort of disconnection of a larger molecule.

Apart from classic chemistry textbooks, can you guys recommend any resources for preparation for such types of interview questions?


r/Chempros • • 7d ago

Analytical Cleaning help for microcuvettes

2 Upvotes

Hello,

My supervisor recently purchased some very expensive cylindrical short-pathlength cuvettes from Starna for me to do CD on very concentrated samples. I started using the 0.01mm one but am having trouble cleaning it after first time use...

I cleaned it by flushing the cell with 1ml water x 6, ethanol + water mix x4 then ethanol x 4. The compound is a very water soluble sugar that crashes out in ethanol, and during cleaning I did not see any precipitated sample in the cuvette. It was then dried upside down over the weekend, but once dry I could see that my sample had dried out on the inside of the polished windows

It seems that flushing solvent through only exchanges solvent in the ring around the polished windows and doesn't actually exchange the liquid in between the two windows/the 0.01mm bit.....

I have already written Starna for a practical guide for cleaning of microcells, but do any of you have any experience using this particular cuvette?

Thank you in advance


r/Chempros • • 7d ago

Reductive amination advice

0 Upvotes

Hi,

I am currently working on a reductive amination with a primary amine and an aldehyde using STAB.

Is acetic acid necessary for this reaction as i'm using STAB as a reducing agent? the aldehyde starting material does also contain a carboxylic acid functionality.

Im using a THF solvent but as i have the HCl salt of my amine it wont dissolve in THF or DCE. is solvation important for redams? Product is forming but after 6 hrs there is still amine in my workup. Will it likely need longer (eg overnight/24hrs)?


r/Chempros • • 8d ago

Writing chemistry papers on Linux: a native structure editor, editable drawings in ONLYOFFICE, and automatic compound numbering

Post image
52 Upvotes

Crossposting for chemists who write papers and theses. Disclosure: this is my project, free and open source.

Reactio Draw is a structure and reaction editor. It now works with your writing tool on every platform:

  • Word on Windows and macOS: copy a drawing in Reactio Draw and paste it into Word as an editable object. A double-click opens it again for editing.
  • ONLYOFFICE on Linux (also on Windows and macOS): the same clipboard paste (Alt+Shift+V) and double-click editing.
  • LaTeX in VS Code, Overleaf and Lattice: paste a copied drawing from the clipboard into your document, and double-click it to edit.

The whole drawing is stored inside the object, so you can still edit it months later on another computer. Compound numbers (1, 2, 3a…) stay in sync between the text and the schemes. It reads and writes CDXML and MOL, so you can still exchange files with colleagues who use other editors.

Repo and releases: https://github.com/Paivel/reactio-draw

Feedback is very welcome


r/Chempros • • 9d ago

Analytical NMR: Does the Nuclear Overhauser Effect travel through the plane of a molecule

Thumbnail reddit.com
7 Upvotes

r/Chempros • • 9d ago

How challenging is it to learn NMR for structural elucidation

0 Upvotes

I have PhD and looking for postdocs and applied for this position that is LCMS and small molecules NMR heavy, during my PhD I have limited NMR experience and wondered how challenging it will to be able to develop more and solve complex structures including absolute configuration etc