r/Cummins • u/JMAnonymous59 • 21h ago
Anyone dealt with p0622 + check gages light? 2004.5 ram 2500 issue said to be common on 03-05.
Iβm assuming I need an external voltage regulator because the alternator is good, batteries are good, connections are good for the most part.
I an wondering if my passenger side negative terminal (oem lead head thatβs kinda cracked) is causing a grounding issue under load.
The thing is, that battery lead has worked fine the way it is for at least 2 years idk why now all of a sudden while driving it died.
the batteries arenβt being drained after start up either, so the ecm might be fried. they drop under normal voltage but come back up to the default 11.9-12.1 ecm reading (read of mm3) but the batteries themselves multi meter test at 12.3 as well as the alternator b+ post only gets the 12.3 volts that the batteries have.
I replaced the alternator 2 pin black ground wire and ran it to the same g120 ground post it was originally at because it shares a ground with the ECM but same issues persists.
on start up, after about 1-2 grid heater cycles the battery gauge on dash hits 0 and triggers check gages p0622 alternator field generator f not detected
anyone fought this demon before? any ideas where to start?
it started on a rainy night drive 1 min away from home so was able to clear code and next day alternator worked fine for about a 20min drive to town but on the drive home it wanted to try to kill the batteries completely but the mm3 isnβt getting proper readings due to the ecm pulsing false readings for everything