Asymmetric phase feed always on

2 Upvotes

Hi there I am running a sun12ksg05lp3 with the 1185 firmware. As far as I can tell, unchecking the asymetric phase feed option does not seem to anything with recent firmware versions. When there is enough battery charge, the inverter will always try to balance all phases. Which is not desirable for me since it will cause the inverter to not provide the full 12kw if the load is distributed unevenly.

Has anyone noticed this as well?


r/Deye • • 4d ago

Deye hybrid inverters in parallel – Uneven PV curtailment and reverse power flow through LOAD ports

Thumbnail
gallery
1 Upvotes

Hi everyone,

I'm experiencing a strange behavior with two Deye 12 kW three-phase hybrid inverters connected in parallel (M01 Master + S02 Slave).

The system has an export limitation controlled through the Master inverter, using an external meter/CT at the grid connection point.

The problem:

When I set a maximum grid export limit of 10 kW, the inverters do not seem to share the PV generation proportionally.

Instead, the Master produces most of the power, while the Slave significantly reduces its own PV generation, sometimes almost to zero.

For example, under a 10 kW export limit, the apparent power flow is:

  • Master generates approximately 10 kW from PV.
  • Around 5 kW is exported through the Master's GRID port.
  • Another 5 kW appears to flow through the Master's LOAD port into the shared LOAD bus.
  • The Slave appears to receive those 5 kW through its LOAD port and export them through its GRID port.
  • Meanwhile, the Slave's own PV generation is heavily curtailed.

So the system respects the total export limit, but instead of both inverters generating approximately 5 kW each, one inverter supplies most of the energy.

What I've observed:

  • The Master's PV generation curve remains relatively stable, reaching around 10–12 kW.
  • The Slave's PV generation fluctuates dramatically throughout the day, repeatedly dropping close to zero during peak sunlight hours.

The batteries are independent, with approximately 20 kWh connected to each inverter. The system has also been tested using Battery First.

My questions:

  1. Is this normal behavior for Deye hybrid inverters operating in parallel under an export limitation?
  2. Does the Master actually distribute the export power reference between the Slave inverters, or does each inverter manage its PV curtailment independently?
  3. Is there a way to make both inverters contribute proportionally to the total allowed export power, rather than heavily curtailing the Slave's PV?
  4. Has anyone experienced this apparent reverse power flow through the shared LOAD bus?
  5. Could this be related to firmware, parallel control settings, or the way the export limit is communicated to the Master?

Ideally, I would like both PV arrays to contribute to the allowed export power without unnecessary power circulation between the inverters.

I've attached the PV generation curves for both inverters and a picture of the Slave's display showing the negative LOAD reading.

Any technical insights or experience with Deye parallel operation would be greatly appreciated!


r/Deye • • 5d ago

Deye Hybrid Inverters with Elevators – Motor Starting Current and Regenerative Braking

3 Upvotes

Hi everyone!

I've seen some older discussions about using Deye hybrid inverters to power elevators, including systems with regenerative braking.

I'd like to reopen this topic and hear from anyone who has successfully installed this type of system, especially those who have been operating it for some time.

I'm currently evaluating a Deye hybrid inverter + battery setup to provide backup power for a residential elevator.

I have two main technical questions:

1. Motor Starting Current and Inverter/Battery Sizing

Assuming the inverter and battery system are properly sized to handle the elevator's maximum transient starting current, including the inverter's AC surge capacity and the battery's peak discharge current limits, should we expect the system to operate normally?

Are there any additional limitations or compatibility issues associated with elevators equipped with variable frequency drives (VFDs), even when the inverter's power and current ratings are respected?

2. Regenerative Braking – Reverse Power Flow Through the LOAD Port

This is my main concern.

During certain operating conditions, the elevator motor acts as a generator, sending energy back through its VFD to the AC supply.

If the elevator is connected to the inverter's LOAD port, can a Deye hybrid inverter safely absorb this regenerative power and use it to charge the batteries, particularly when operating completely off-grid?

Let's assume the battery is intentionally kept below 100% SOC, with enough available capacity and charging power to absorb the regenerative energy.

Would this be sufficient to guarantee safe operation, or could the inverter still experience faults due to the characteristics of the regenerative power?

For example:

  • Could sudden reverse power flow cause DC bus overvoltage, AC voltage/frequency instability, or inverter protection trips, even when the battery is not fully charged?
  • Are there limitations regarding the magnitude or duration of reverse power entering the LOAD port?
  • Is regenerative charging through the LOAD port officially supported by Deye, or does it depend on the inverter model and firmware?
  • Would installing a braking resistor, properly integrated with the elevator's VFD, eliminate these risks? Or could problems still occur even with a braking resistor?

3. Real-World Experience

For anyone who has already installed a Deye hybrid system powering an elevator:

  • Which inverter and battery models are you using?
  • What is the elevator's rated capacity and motor power?
  • Is the system operating reliably during grid outages?
  • Have you experienced any inverter faults during elevator starting, stopping, or regenerative braking?
  • Did you need to install braking resistors or make any special configurations?

I'd especially appreciate feedback from installations that have been running for several months or years.

I'm very interested in understanding whether this is a reliable long-term solution and what technical precautions should be considered.

Thanks in advance for sharing your experience!


r/Deye • • 5d ago

Felicity battery compatibility

1 Upvotes

I have a Deye SUN-10K-SG05LP3-EU-SM2 and I’d like to buy a Felicity FLA48314-EU. Does anyone know if the battery is compatible with my inverter? I can get it around £150 cheaper than Deye’s own Se-F16-C.


r/Deye • • 5d ago

PSA: Deye 3-phase (SG04LP3) not discharging battery in On-Grid mode (0 W net output), works fine in Off-Grid — check hidden Modbus Register 231

2 Upvotes

If your Deye LV 3-phase hybrid inverter (e.g., SUN-10K-SG04LP3, tested on FW 2006-1185-1807) works fine in Off-Grid mode, shows 0 alarms/faults, has valid CT readings and active Time of Use, yet refuses to discharge the battery in On-Grid mode (balancing phases with a 0 W net sum and pulling 100% of home load from the grid), check Modbus Register 231.

The cause: Register 231 (exposed in ha-solarman as number.inverter_grid_max_export_power, scale 10) is not visible on the inverter's HMI screen or in the standard DeyeCloud UI. Despite its misleading name, it does not control grid sell-back—it acts as a master active-power ceiling for the inverter bridge in On-Grid mode. When set to 0 (0 W), the inverter blocks all battery discharge to the home load while grid-tied.

The fix: Set Register 231 (Grid Max Export power) to your inverter's rated power (e.g., 1000 raw = 10000 W for a 10 kW unit) via Home Assistant / Modbus, or ask Deye support to update it remotely. Zero export to the grid is still strictly enforced by Work Mode: Zero Export To CT (Reg 142 = 2) and Solar Sell: Disable (Reg 145 = 0).


r/Deye • • 6d ago

Mobile APP update = 10 second refresh finally.

3 Upvotes

This will make a lot of people with adhd feel better.


r/Deye • • 6d ago

8K-SG01LP1-US + 15KW-SG01LP2-US-AM3 sharing same battery bank

2 Upvotes

Hello everyone,

Currently I have a 8K-SG01LP1-US connected to my battery bank with BMS. I need to upgrade my system and a 15KW-SG01LP2-US-AM3 will fit perfectly, having these two inverters sharing the same battery bank would avoid me to spend more more money buying another one.

Here is my plan:

Disable 8KW export to grid and disconnect the battery BMS.

Install 15KW inverter on a separated load with export to grid.

Have both on same DC busbar.

Connect the battery BMS on 15KW.

Configure the 8KW to operate with battery voltage.

Anyone with similar case?

Both inverters charging at same time would be a problem? (Using same charging voltage)

Any issues I'm not counting on?

Thanks!


r/Deye • • 7d ago

Looking for Deye Battery CAN bus dump sample

2 Upvotes

Hi everyone,

Does anyone have a CAN bus dump sample from a Deye battery?

I am looking for raw CAN frames/log files captured from a Deye battery communication bus for analysis.

Any format is fine (.csv, .txt, .log, etc.).

Thanks!


r/Deye • • 7d ago

CC Peak Power in Off-Grid (only Batteries)

1 Upvotes

Hello everyone, rescently I starter a project and I have to start an motor completely offgrid with an Deye 220/380V 15kW inverter, and up to 4 x DEYE SE-F5 Battery. (SUN-15k-SG05LP3-EU-SM2) (low voltage)

The thing is: for a short period of time, in the worst possible outcome (probably never happen but it can), It can need 25kW of power to start a motor with max load.

The thing is, this inverter can take 2x the rated power (Offgrid) for 10s, but my question is: the CC Bus have a max discharge of 280A, in these peak power when the inverter can send up to 30kW for 10s, the CC bus can suplly up to 560A (280*2) for the inverter, so it can deliver the rated 30kW?

The Deye Battery can supply the current (150A@10s * 4 = up to 600A@10s) but the BMS and the inverter can make it happenn?

someone have already tried smt like that?


r/Deye • • 8d ago

Deye NV vs. HV / 20K SG05 vs. SG01 / BOS-G vs. SE-F16-C

2 Upvotes

Hey everyone,

While looking for an inverter for my PV system (two strings of 9.7 kWp each), I had initially settled on the Deye 20K SG05 as my preferred choice. The features that particularly appealed to me were:

  • Home Assistant integration
  • Affordable low-voltage battery storage (SE-F16-C)
  • Grid peak shaving
  • Shade management
  • GEN port with Smart Load functionality and microinverter integration

Until now, I had always assumed that a high-voltage (HV) system wouldn't be worthwhile for me or would simply be too expensive.

However, I've now come across the 20K SG01. It's actually cheaper, offers more headroom with a maximum PV open-circuit voltage of 1,000 V, and is compatible with Deye's BOS-G battery system, which works out at around €100/kWh.

On top of that, you get the advantages of an HV system, such as thinner cables and lower energy losses.

So, what's the downside of going with the "older" SG01?


r/Deye • • 21d ago

Deye SUN-8K-SG06LP1-EU-CM3 + Pylontech FB-L 5.12 battery repeatedly stops charging at 84% SOC – remote update temporarily fixes the issue

2 Upvotes

I’m experiencing a recurring charging issue with my Deye SUN-8K-SG06LP1-EU-CM3 inverter and Pylontech FB-L 5.12 (51.2V, 5.12kWh) battery. The battery repeatedly stops charging at around 84% SOC despite sufficient sunlight, with no alarms. Previously, resetting the inverter allowed it to reach 100%, but the issue returned. On November 3, 2026, a technician performed a remote online update, and the SOC immediately jumped from 84% to 100%. The technician was not physically near the battery, and I don’t know whether the inverter or BMS was updated. Could this be a firmware, BMS communication, or SOC synchronization issue? Has anyone experienced this, and how can I identify the root cause?


r/Deye • • 21d ago

Inverter beeping at first startup

1 Upvotes

The display seems to not be responding?
No battery connected yet, only the grid is connected


r/Deye • • 22d ago

Commissioning the Deye SUN-20K-SG05LP3 Inverter Myself – DRM Function and Compliance with Sections 9 and 14

2 Upvotes

Hi everyone,

I’m currently planning a 19.4 kWp PV system (two strings of 9.7 kWp each, with 20 AIKO-A485-GRH48Dw Neostar 2P+48 modules per string) and have pretty much settled on the Deye SUN-20K-SG05 inverter.

Finding an electrician has proven difficult. So far, only one has agreed to commission the system, but only on the condition that I don’t use the “dumb” Deye inverter, as he isn’t familiar with it.

However, I can’t find an alternative in his inverter portfolio that offers the same features as the Deye, so I’d like to install it myself.

The electrician is fine with this, provided that the requirements of Sections 9 and 14 can be met.

Could you help me with this? What do I need to consider? The Deye has a DRM function, which should already be an advantage.

Thanks in advance for your help!


r/Deye • • 22d ago

Anyone familiar with deye time of use settings?

Thumbnail
gallery
2 Upvotes

I have set it to use up to 35% of battery soc. But currently it stops battery discharge by 40% and pulling power from the grid.

Can anyone tell me, if I missed some settings configuration?

Inverter - SUN-5K-SG04LP1-EU

Battery - SE F5 PLUS L


r/Deye • • 25d ago

New inverter firmware adds new features on EV charger.

5 Upvotes

Version Main 1727 - HMI C387 adds ADJ SOC option. Tell your peeps we can now set the SOC % threshold!

They need to now work on the mobile app to make this available.

Promising!


r/Deye • • 27d ago

Welcher Hybrid-Wechselrichter/Batteriespeicher für 18,43 kWp mit HA-Integration

Thumbnail reddit.com
1 Upvotes

r/Deye • • 28d ago

Update on post "New Deye SUN-15K-SG05LP3-EU-SM2 – F21/F47, bang and smoke during first startup "

6 Upvotes

Final update on my original post: https://www.reddit.com/r/Deye/s/TAHxIFgnd7

Thanks everyone for all your replies.

I wanted to give one final update, as the cause has now been clarified.

The inverter was inspected and repaired by Deye. According to their feedback, this was explicitly not an installation error, but a fault within the inverter itself. The power/driver board inside the unit had to be replaced.

The official repair report also states that no incorrect settings were found during testing. After replacing the board and updating the firmware, the inverter passed Deye’s functional tests.

The repaired unit has now been reinstalled and is running normally. Before putting it back into operation, we checked the system again and also reconfigured and tested the CTs.

At one point, we also considered a moisture-related insulation fault because the original failure happened during rainy weather. However, there is currently no evidence for that — and more importantly, Deye themselves classified the damage as an internal inverter fault.

Thanks again to everyone who helped think through the troubleshooting process. Hopefully this update will be useful to anyone who runs into a similar issue with F21/F47/F55 occurring immediately when the PV side is switched on.


r/Deye • • Oct 25 '26

Real-time data view

3 Upvotes

Is it possible somehow to set up a real-time data update instead of every 5 minutes?


r/Deye • • Oct 24 '26

Panels (15x505W) and inverter compatibility check

1 Upvotes

Someone told me a 15 × 505 W string is "too close to the limit" because the inverter's rated input is 550 V, and that it would curtail early.
Also someone else said that 800V is the limit for both MPPTs and when using only one the limit is 650V.
I checked the datasheets.
**Inverter (Deye SUN-10K-SG05LP3-EU-SM2)**
550 V is the *rated* input voltage. The actual limits are 800 V maximum, a 200-650 V MPPT range, and 26 A per MPPT.
**Panel (TCL HSM-ND54-DR 505 W, STC datasheet)**
Vmpp 33.90 V, Impp 14.90 A
Voc 40.14 V, Isc 15.88 A (17.47 A with 10% bifacial gain)
Voc temperature coefficient: -0.25 %/°C
**15 in series**
Vmpp: 15 × 33.90 = **508 V** at STC
Voc: 15 × 40.14 = **602 V** at STC
Cold (from 25 °C, +0.25% per °C below):
\-10 °C: Vmpp about 552 V, Voc about 655 V
\-25 °C: Vmpp about 572 V, Voc about 677 V
Vmpp cold figures are an estimate, since the datasheet has no Vmpp coefficient and I used the Voc one.
So in normal operation the inverter sits near its 550 V rated point, and even at -25 °C it is under the 650 V MPPT ceiling. Cold Voc stays well under 800 V and only matters at start-up with no load. Current is 14.9 A against 26 A. 7.6 kWp on a 10 kW inverter should mean no clipping.
I’d rather not split in two strings as I have limited space for cables in conduits.


r/Deye • • Oct 23 '26

Usage of the backup port

2 Upvotes

Am I understanding correctly that connecting all loads to the backup port makes it work in such a way that if I exceed the power load rating of the inverter, it turns off?
And if I also set ‘zero export to load’ it behaves the same as an offgrid inverter, i.e. no way to export to the grid (even temporarily during transitory)?


r/Deye • • Oct 21 '26

SH04LP3 vs SG05LP3?

1 Upvotes

Hello, I’m looking to buy a Deye hybrid inverter. I have found these 2 versions, the SG05LP3 seems to be newer, but what are the differences beyond the aesthetics?


r/Deye • • Oct 19 '26

Deye Gen Start/Signal feature

Post image
2 Upvotes

I want to know how to connect a deep sea controller for a genset to auto start/ stop the generator using the gen start feature.

What termails I should connect the inverter pins to?
If there is any programming to be done in the controller?


r/Deye • • Oct 17 '26

Sun15k sg05lp3 quite noisy

3 Upvotes

Hellow everybody, I am a proud owner of a 15kw SG05 LP03 inverter. I am impressed by this "beast" :) but I have one downside with it, the fan is noisy. Can the fans be exchanged with some premium, low noise ones ? In the same time, keeping the cooling capacity or even improving it ? Has anyone else encounter this or is it just mine that is loud ?


r/Deye • • Oct 17 '26

Netzbezug beim SUN-20k

1 Upvotes

Ich werde gegebenenfalls einen SUN-20K-SG05LP3 EU mit 15kWh Speicher installieren, habe aber hier im Forum und an anderer Stelle gelesen, dass der Wechselrichter bis zu 200W Strom aus dem Netz bezieht. Das wäre natürlich äußerst ungünstig hier in Deutschland.
Hat jemand hier Erfahrungen? Wurde das Problem eingedämmt?


r/Deye • • Oct 15 '26

Nice move Deye - app upgrade

5 Upvotes

Looks super flash, I really like it. I really like the fact it will convince prospects that only get put off by the app layout.

I would put the AI assistance bubble at the footer bar of options, next to Device.

well done Deye team.