r/ElectriciansUK • • 3h ago

Removing an old storage heater, replacing it with an oil filled electric radiator. How much would an electrician ask for to complete this?

1 Upvotes

Old storage heater has two wall switches, one for the night rate presumably, the other for the daytime convection heater.

Does removing this and replacing it with a 2kW electrical radiator require the actual property circuitry to be reconfigured?

What could one expect the cost of this job to be, on average?


r/ElectriciansUK • • 8h ago

How concerned should I be - 32amp Breaker supplying 9.5Kw Shower

Thumbnail reddit.com
2 Upvotes

r/ElectriciansUK • • 9h ago

Invt 6kW Hybrid + 16kWh Eco-Worthy Battery — Sanity check on Automatic Bypass Contactor Box for EPS?

Post image
1 Upvotes

Can anyone help advise the best solution?


r/ElectriciansUK • • 9h ago

Monitoring Electricity

Thumbnail reddit.com
1 Upvotes

r/ElectriciansUK • • 10h ago

How to swap ceiling lights

Thumbnail
gallery
3 Upvotes

Wantng to swap ceiling lights but didnt realise how many cables were under the old one.

Not sure how to do the swap given the configuration.

Any help would be appreciated


r/ElectriciansUK • • 16h ago

Question about repurposing a power outlet.

Thumbnail reddit.com
1 Upvotes

r/ElectriciansUK • • 1d ago

Payment when warranty documents not provided

Thumbnail reddit.com
0 Upvotes

r/ElectriciansUK • • 1d ago

Aspiring electrician looking for advice on how to get established in the trade

6 Upvotes

I'm 19, I've got my electrical qualifications, my own tools and transport, and I'm genuinely trying to build a career in the electrical trade. The difficult part has been finding consistent work and getting the site experience I need to become fully qualified. I have just recently started my lvl 3 nvq, so im trying to build as much onsite portfolio evidence and experience so i can hopefully do AM2. 

I'm based in South London. I have ECS labourer card, 2391, 18th edition, part p and pat testing. I have my own tools, car and full clean uk driving licence. So I'm half qualified, just lacking experience and gold card. 

2 weeks ago, I finished a short term domestic contract doing eicr, remedials, as well as first and second fixing (as an electrician mate). Before that I was doing commercial installation at a school (agency work august-september). And my first job was during July-August testing NTC fire alarms, aov, and installing emergency lighting. 2026 July was when I received my qualifications so I started to work.

So I have been searching for as many electrician mate/improver roles I could find. I dont have much industry connections so it's been quite hard for me to find further work opportunities. Most of my experience has just been short term agency work as I'm very new to the industry (4 months practical experience), I'd really like a long term opportunity alongside experienced electricians that would help me grow and teach me alot. 

Im willing to drive and relocate 1 hour out of London if needed, i currently dont live with parents. So I pay all my own bills and I'm running low on savings so I'm heavily looking for work now. I would really like to get IPAF and Pasma when I can afford it hopefully. My plan is to continue my LVL 3 NVQ and pass AM2. And have an opportunity to work with a company long term.

Any advice on how to get good opportunities would mean the world to me. If anyone has any experience or guidance please feel free to share. Thanks for taking the time to read this, and take care.


r/ElectriciansUK • • 1d ago

Learn to prepare for my level 3

1 Upvotes

Like the title says I want to learn electrics for my level 3 but I don’t really understand the concept of it. I am doing a 7 week course for it but wanted to prepare for it and try to understand before I go so I can understand what the tutor is telling me are there any slides, websites, apps or is it a good idea to use google ai and ask questions.


r/ElectriciansUK • • 1d ago

Old fuse box in house under offer - surveyor says it needs replacing immediately

Thumbnail gallery
1 Upvotes

r/ElectriciansUK • • 2d ago

Ledtube T8 starter

1 Upvotes

Hello,

I bought a fluorescent tube Osram Ledtube T8 , it says it needs a starter but I think my old tube (no LED) didn't have one and I don't think there is one in the base where the tube hangs from ( sorry I dont know now the name ). Will the new tube not work?


r/ElectriciansUK • • 4d ago

Lettiing property - electrician says EIC can be the EICR

3 Upvotes

Letting agent disagrees and wants us to pay to have an EICR done.

We had an EICR done 3 years ago but a couple of months ago we had a new consumer unit fitted, along with new wiring for fixed electric panel heaters. I think this makes the old EICR invalid? We are trying to market the property for rent now and the letting agent says we need an EICR, while our electrician emailed me after with the paperwork and said:

"EIC (Electrical installation certificate) for newly installed consumer unit and all outgoing circuits. This will act as a satisfactory EICR for the next 5 years."

I know he inspected all the circuits fully, so I have no doubt that everything is in good working order, but I know the letting agent needs to check the box for compliance. So who is in the right here?


r/ElectriciansUK • • 4d ago

Help with Level 3 NVQ

4 Upvotes

Hey all, hope your Mondays have gone well!

I'm leaving my 15 year IT career to become an electrician, I've completed the level 2 and just started the level 3 diploma. I'm also enrolled on an EESS course and looking to do 18th soon.

Very soon I'm going to be looking to start the level 3 NVQ but I'm struggling to get any engagement from local firms on trainee/Mate positions to get the evidence together.

Can anyone give advice on how you did it? Am I missing something? I'm in the South Wales area - Merthyr Tydfil if that makes an ounce of difference.

I'm particularly interested in domestic work and green energy installations but would obviously take anything to be able to build a portfollio.

Really appreciate any advice you can give.


r/ElectriciansUK • • 4d ago

This is getting ridiculous. Help me find a bulb for my bathroom please?

1 Upvotes

I have a fluorescent tube bulb in my bathroom that recently blew. It's a 4 pin 21 watt 3500k tube that doubles back on itself like a double D.

I've already ordered two replacements and they don't fit- the old bulb is about 14cm across, the new ones are all around 20cm.

I'm reading that you can't actually get new fluorescent bulb stock in the uk any more? So these bulbs are just whatever's left in stock?

I'd be happy getting an LED replacement but can't figure out if that would just work or if you'd need to change the actual light bulb fitting.

Any electricians/ anyone with experience of this can help point me in the right direction please?

(Bring on the how many *guyal*s it takes to change a lightbulb! Feel I deserve it at this point)


r/ElectriciansUK • • 4d ago

Lighting circuit with son :-D

Thumbnail
vm.tiktok.com
1 Upvotes

r/ElectriciansUK • • 4d ago

Searching for Oversized Cooker switch plate

2 Upvotes

I’m trying to replace a dual oven/single plug faceplate but I would prefer not to have to replace the box as well. I ordered a current standard one and ofc the faceplate is too small for the box that’s on the wall… The one I’m searching for is 11x16cm, and I can’t find anything that matches.
Do these still exist or am I literally searching for a needle in a haystack??


r/ElectriciansUK • • 5d ago

Help with extension lead!

1 Upvotes

Clueless about these things, please help.

I found one from pro elec, it says supply voltage VAC 250V, is that okay? Or is that too high?

I’ve read most are 230V


r/ElectriciansUK • • 5d ago

Part time advice ?

Thumbnail reddit.com
1 Upvotes

r/ElectriciansUK • • 6d ago

Doorbell Transformer for LG Doorbell

2 Upvotes

I’m looking to purchase an LG Doorbell (https://www.apple.com/uk/xc/product/HSN82B/A) but I’m struggling to find a transformer for it so any help would be much appreciated!

Doorbell requirements:
16-24V AC
30VA

If possible I’m looking to have a fully self-contained transformer instead of needing to have a small consumer unit box in my hallway. This will replace the existing chime unit and Ring transformer box I’m currently using that has 2 module DIN rail inside - from looking it seems that 30VA is minimum 3 module.

I’m not an electrician but am quite confident in changing plug sockets, light fittings and have previously wired a Logitech doorbell (imported from the US) which I initially had difficulty finding a transformer with VA that was high enough. However this seems impossible without a large unit!

Thanks!


r/ElectriciansUK • • 6d ago

Bathroom De-misting Pad + Dimmed Lights Wiring

Thumbnail gallery
1 Upvotes

r/ElectriciansUK • • 7d ago

Am I an unreasonable customer?

1 Upvotes

Homeowner here, not an electrician, so happy to be told I've got this wrong.

I'm having a 10 kW hybrid inverter and battery installed (battery only, no PV), £6,500 with a deposit of just over £1k paid on 21 September. We discussed the G99 application and whether to include a G100 export limit at the time.

- **21 Oct:** asked how the G99 was going. No reply.

- **22 Sep – 13 Nov:** no contact, then a call saying the battery was arriving.

- **13 Nov:** G99 submitted via ENA Connect Direct.

- **18 Nov:** SSEN told me it should go to them directly. I passed that on.

- The resubmitted application showed a PV array I don't have and isolators rated well below the inverter's output. I replied to the email (I was CC'd) listing the errors.

- Since then, calls have mostly gone unanswered. Today I was told the battery arrives Monday. When I said we needed to talk about the G99, he said he had to take another call.

The installer wants to apply for the full 10 kW export without a G100 scheme and let SSEN reduce it. My Ze is 0.20 Ω and I've seen readings up to 252 V, so I've asked for the G100 to go in with the application, to avoid back-and-forth.

I also noticed that G99 Issue 2 adds a battery requirement for anything connected from March 2026, but the specified Solis inverter is only type-tested against the previous issue. I've asked Solis about it.

I know I've become quite involved, and I'm aware that may make me a difficult customer. Genuine questions:

  1. Is any of this normal for a domestic battery install?
  2. Am I being unreasonable to be upset that the G99 wasn't started until almost two months after I paid the deposit?
  3. Is it unreasonable to want the G100 submitted up front?
  4. Does the Issue 2 type-test point matter in practice?
  5. Should I step back and let them get on with it?

Thanks.


r/ElectriciansUK • • 7d ago

What happened to my electric blanket?

Thumbnail reddit.com
1 Upvotes

r/ElectriciansUK • • 7d ago

Is this supply 3 phase?

Post image
14 Upvotes

We have a very old home in a slightly rural area.

I know I have a single phase meter, with economy 7, but I wonder if the supply is or could be 3 phase due to the 3 fuses on what I think is the DNO. Supply head (?).

We are looking to get an EV and considering a battery system with a possible future heat pump to replace an oil boiler.

I think my first step might be to get a smart meter to get more data on my usage patterns. Want to understand if I should get a 3 phase meter even if I only use a single phase for now.


r/ElectriciansUK • • 8d ago

Still not happy with electrician's repair of damage he caused.

3 Upvotes

Context in original post here;

https://www.reddit.com/r/DIYUK/s/VjyeiTVuME

I'm seeking advice about an electrician who has damaged my home and bodged the subsequent repairs. This has been going on since 1st October.

To summarise; an electrician core-drilled through my/my neighbours lead flashing when installing an extractor fan.

After several weeks of him avoiding repairing his mistake, I ended up threatening legal action, after which the electrician finally agreed to send out a roofer at his cost.

The roofer did repair the flashing with some kind of lead alloy...? Following which he repaired the interior hole with foam (?!)

When I noticed foam was being used, I voiced concern to the roofer, saying I had requested the hole was made good with brick. The roofer said that message hasn't been passed on, but assured me the hole would be water tight.

I said I still wasn't sure, and he said if I wasn't sure he would cover it with cement too. I eventually agreed to this, on the promise the standard would be as good as before. Yes, I know, I shouldn't have.

A few days later the neighbour told me he can see from his window that the cement hole has slightly cracked.

I have been busy with a new job and stupidly thought this repair would be fine. 9 days later, today, I went into the loft to check, as we have had bad rain and as I suspected, the brickwork around the cement hole is "breathing" in and out slightly when pushed (video:https://file.kiwi/5534f122#b8sYYWfY6hAkNzlnoroT1g)

Regarding this latest ""repair"", I'm correct in thinking this is totally unacceptable, yes?

Am I also right in thinking there is still a risk of water ingress and further damage to the walls because of this?

The breathing brickwork is only on the interior of what I think is two walls, but I'm not optimistic about the standard of the exterior wall either.

Pursuing the electrician up to this point has been extremely stressful and he has been dragging his feet as much as possible with sorting the repairs up to now.

Also, every time he has come out to make repairs the job has been very sloppy. Therefore I do not trust him to make any more repairs, by himself or via anyone of his subcontractors.

So I feel like I have two options;

  1. Pay for proper brick repair out of my own pocket. 

(I do not like this option, the tradie has damaged my property and agreed, in writing, to rectify the issue.)

2) Organise repairs, then invoice the electrician, followed by a letter before action to recoup costs via legal means if necessary of he doesn't pay.

(I have already served the electrician an official final request for repairs, stating that I would send a letter before action)

I'm wondering if I have weakened my position by accepting the work when the roofers had attended, although I did vocalise my concerns more than once. I do feel very stupid about the whole situation but I could really use some advice.

Thanks 


r/ElectriciansUK • • 8d ago

Cable pull rods light / torch

Post image
3 Upvotes

I bought some cable pull rods and one of the attachments was a torch/light. I can’t get it to work though. There are 5 LR41 batteries, a small flat metal disc and the bulb. I can see which side the bulb screws into and a rod screws into the other side. Does anyone know which way up the batteries go and where the metal disc goes?

Ill also try getting some fresh batteries but if I can’t work it, does anyone know where I can buy a replacement bulb like this one?