r/Ender3V3KE • u/Opposite-Engineer • 8h ago
Troubleshooting V3 KE works on NebulaOS, won't start up on factory firmware
A V3 KE came to me stuck at the Creality logo after someone did "something" with the firmware. As part of my troubleshooting, I loaded NebulaOS to it (via the micro USB / USB cloner / .ingenic file) and it functions perfectly that way. So, I then loaded the factory Creality firmware back onto it (same process, just using the .ingenic file from Creality) and it once again gets stuck at the Creality logo.
I then tried re-loading NebulaOS (which worked fine again), and then using Nebula's built in function to switch to the alternate firmware (which the NebulaOS .ingenic file includes containing factory Creality firmware), and that also get stuck at the Creality logo.
Since I'm using the Creality firmware from two different sources (the first being directly from Creality, the second being the alternate firmware of NebulaOS), I conclude that there is something about my specific printer preventing it from running the Creality firmware.
I'm not sure where to go from here. I'd like to be able to use the Creality stock firmware. I did look at the sn_mac partition but mine looks fine and has the correct structure for a KE with the original KE nebula pad F005; so I don't think that partition is corrupted (and certainly wasn't erased). From what I can tell, that's the only partition that the usb cloner tool doesn't erase (based on the contents of the MMC tab) so I reasoned that anything "bad" about that partition MIGHT cause the factory firmware to fail boot; but I just don't see anything wrong. Everything else should have been reset/overwritten by the .ingenic files.
Any ideas?