r/SunPower • • Oct 06 '26

[MOD] We Need Your Help Protecting the r/SunPower Community

22 Upvotes

In this day and age, all over the internet, we have seen an increase in the number of scams and their sophistication. We want to remind members of the r/SunPower community to be vigilant.

SunPower’s bankruptcy has increased the burden on all of us. Many of us purchased a SunPower system because while we wanted solar, we did not have the time and/or desire to become a solar expert. As a result of the bankruptcy, we no longer have a trusted partner to turn to when we need help and support. Unfortunately, the need for help and support and the uncertainty surrounding it have increased the opportunities to be scammed by promises of help and support.

To make r/SunPower community safer, we have:

  1. Prohibited businesses from posting advertisements for goods and services on r/SunPower (rule #1).
  2. Discouraged businesses from replying to requests for help with “I can help, dm me”. This is exactly what a scammer would do. Instead, we encourage businesses to put more effort into their responses. To demonstrate a professional understanding of the problem and a plan to resolve it. A potential customer on Reddit doesn’t need to be told how to reach out. They want to know:

    1. Are you a legitimate business?
    2. Do you understand their issue?
    3. Are you capable of resolving it?
  3. Encourage businesses to build out their Reddit profiles. To help potential customers get a better sense of who they are potentially working with while looking at their Reddit profile. We encourage businesses to do more than just fill out their Reddit profile description. Businesses should have pinned posts with relevant information about their business, detailed contact information, goods and services offered, service areas, issues they have resolved, success stories, referrals, etc.
  4. Encourage the r/SunPower community to continue to post issues they are having with their SunPower systems. Also post a follow-up with their success story.  Include how the problem was resolved, which business resolved the problem, and their experience with the business.

r/SunPower • • 2d ago

New/Strange Sunvault Charge Behavior

Post image
4 Upvotes

Today I have new behavior…
I was charging my car mid-morning. At this time of the year the solar is never enough to cover that load, so some grid is needed and if any charge is present above my self-supply limit, energy will be taken from the battery.
Near then end of charging the car, I happen to walk by the sunvault and saw that the status light indicated the battery was charging (strange, I thought). A little while later, post car charging I saw the battery was fully charged. So I open the app and saw that while the car was charging, the sunvault was also charging and solar was nowhere near enough to cover that, so grid power was drawn.
Anyone else see this behavior?
The app used to show my the date of the last firmware update, but it doesn’t seem to show that anymore so I don’t know if its due to new firmware.
The photo shows the behavior…


r/SunPower • • 3d ago

PVS2 support is here!

Post image
8 Upvotes

If you have one of these legacy systems and have been looking for a solution to restore your monitoring, I’m pleased to announce that Solar Monitor officially supports PVS2 (SMSPVS20R1) units! Let me know if you have any questions.

You can learn more about Solar Monitor or purchase one on my website: https://solar-monitor.app


r/SunPower • • 4d ago

WattHacker

7 Upvotes

I had originally purchased my solar system through SunPower. Once they were acquired their app went away. the new app in its place is so so. I found WattHacker easily integrates into my current system and provides much better data and overview of my current system and efficiency. It even has something that can look out how shade affects your production and can recommend things to help! The app is easy to use and has a clear presentation of data and creates a great user experience. They keep adding more features on a regular basis vs just a stale boring app! I love WattHacker and highly recommend it!!


r/SunPower • • 4d ago

Roof Mounted Solar Panels

Post image
1 Upvotes

I want to put 2 or 3 panels on the roof of my shed. I have some ideas regarding how to mount them but really don't know how the professionals do it. Anyone have suggestions or advice? Sources for supplies needed? Thanks.


r/SunPower • • 5d ago

Beta testers wanted: Neighbor Solar, Android app for SunPower panel-level monitoring (PVS5/PVS6)

4 Upvotes

Hi all — I'm a SunPower owner and I built a small Android app for my neighbors that shows live energy flow and per-panel output from your own gateway. It pairs itself on your home Wi-Fi, no account, no cloud, nothing leaves your phone.

I'm looking for beta testers to run the closed test Google requires before I can publish it. You need:

  • Android 7.0 or newer
  • A SunPower PVS5 or PVS6
  • To stay opted in for 14 days

It is a paid app ($5.99/year) but the 15-day free trial covers the whole test, so you pay nothing.

How to join:

  1. Open the beta group link: https://groups.google.com/g/neighbor-solar-testers — sign into your Google account if asked, then tap Join group.
  2. Then opt in on Play here: https://play.google.com/apps/testing/com.sushi.neighbor_solar

Note: after joining the group, it can take a few minutes before Play recognizes you. If the Play link says unavailable right after you join, wait a bit and try again.

If you don't have a PVS you can still join the group and count toward the 12 testers Google needs, but the app will stop at the gateway scan since there's nothing to connect to.

Happy to answer questions here. Mods, please remove if tester calls aren't allowed.


r/SunPower • • 8d ago

End of the World

0 Upvotes

Solar panels were never activated.

How do I get the solar panels to produce and power the house and not export to the main grid?

From my research, the solar panels have microinverters.

I have a sunpower PVS6 that doesn't do anything since it was never activated.

Is it as simple as swapping out the PVS6 with something else?

I just want to be able to charge my ecoflow batteries using the wall outlet during the day.

This would be ideal during weather emergencies or end of the world scenarios.

Basically so I can heat up my ramen noodles.


r/SunPower • • 8d ago

tapping PLC microinverter telemetry: exploring the PVS6 Line Input Board, part 2

8 Upvotes

Last time, we looked at how the PVS main board communicates with the LIB and found some tap-points for the various UARTs on the Line Input Board.

This time, let's look specifically at what the traffic between the main board and LIB looks like on those UARTs when the normal main board is present and running so we can understand how microinverter telemetry is acquired for eASIC-polled microinverters like the IQ7XS/IQ7AS/IQ7HS and SPWR-A5.

Right away we notice there are frequent bursts of bytes that start with 0x00 and end with 0x00. Here are a few from today:

11:56:50.122  00 03 aa 01 01 12 0d 26 6a 56 5f 35 43 53 0e b2 43 bb 86 2c 45 49 77 00
11:56:50.201  00 03 aa 01 01 12 0d 26 6a 6d 91 41 43 9c 30 b7 43 f6 97 2c 45 dc 54 00
11:56:50.359  00 03 aa 01 01 12 0d 26 6a 51 35 94 43 f1 b6 bb 43 7e a9 2c 45 75 2e 00

This sort of starting and ending with ASCII NUL - 0x00 - is one way to mark the start and end of data packets. But then you need to make sure 0x00 doesn't appear in the actual content, so you can use an encoding called COBS - Consistent Overhead Byte Stuffing.

Once we apply a COBS decoder to each frame, we can see the actual frame contents:

11:56:50.122  aa 01 00 00 0d 26 6a 56 5f 35 43 53 0e b2 43 bb 86 2c 45 49 77
11:56:50.201  aa 01 00 00 0d 26 6a 6d 91 41 43 9c 30 b7 43 f6 97 2c 45 dc 54
11:56:50.359  aa 01 00 00 0d 26 6a 51 35 94 43 f1 b6 bb 43 7e a9 2c 45 75 2e

In every frame, the first bytes are the same: aa 01 00 00 0d 26 6a. Whatever is there isn't changing within one second. A little more subtle: we can see that 0x43 and 0x45 are also the same in their respective positions across the frames.

11:56:50.359  aa 01 00 00 0d 26 6a 51 35 94 43 f1 b6 bb 43 7e a9 2c 45 75 2e
                                            ^^          ^^          ^^

And there's a nice symmetry there: they're all the same distance apart - 4 bytes. So probably we're looking at three 32-bit numbers of some kind that are fairly steady across intra-second readings. And since the last one doesn't have 4 bytes following it, it seems like the most significant bytes are last: Little Endian.

There are a few common ways we could interpret these bytes into 32-bit numbers: signed integers, unsigned integers, and floating-point numbers. Let's try that with just one number - the biggest one.

7e a9 2c 45 LE = 45 2c a9 7e BE = 1,160,554,878 as an integer - the same as signed or unsigned, because 0x45 = 01000101 in binary, so the first sign bit is 0.

45 2c a9 7e BE as a 32-bit IEEE 754 floating-point number is about 2762.59.

If we look at the other two numbers, we get an important hint: as integers, they're within a few percent of each other (about 1.14 billion), but as floats, they turn out to be a bit more different: 296.42 and 375.43.

At about this time, my panels were producing about 2.8 kW - 2,800 watts - of power and my home was consuming about 600 watts, so it seems likely that the large number is the production CT power value in floating-point format. We know that there's one production CT and there are two consumption CTs, so logically, the other two values are probably the consumption CT power values for L1 and L2. If we look at the values for L1 and L2 power at that time via the varserver API for /sys/devices/meter/1/p1Kw and p2Kw, that's about what we see, and the two consumption phases indeed sum close to the expected consumption total!

So what we are seeing, several times a second, is the power measurement for the production CT and consumption CTs.

The last 2 bytes look almost random over time, which is a sign that they're a checksum. 16-bit checksums are often CRC-16, like in Modbus. If we try CRC-16 over the prior bytes in the frame with some common polynomials/inits like Modbus, ARC, XMODEM, and so on, we get a bucket of disappointment - none of those match. But if we tell our close personal friend Claude "here are some frames, write a script to run some common 16-bit checksum algorithms over the bytes preceding the checksum and alert when one's result matches the actual checksum", we find out in short order that it's CRC-16/MCRF4XX - polynomial 0x1021, init 0xFFFF, reflected.

But isn't this a post about microinverter telemetry?

Yes, yes it is.

Sorry for the detour: if we don't have COBS framing and decoding to split up the data stream and fix the 0x00 bytes, we will be led astray on decoding the microinverter data - we will have other wildly varying numbers where we should have 0x00 which will be extremely confounding and frustrating. Ask me how I know!

And this is a nice toy example for showing how we figure out what's inside: look at what varies, look at what's fixed, use what we know about common data formats to get some candidate values, and see if that lines up with any parts of the system or data we have from other sources at the time of observation.

We know the microinverters communicate with the LIB over PLC - powerline communications. And we know they don't update every second of the day; we also know they update at least every 5 minutes based on the data update rate in the varserver API.

If we look at a longer capture, we see aa 01 prefixed frames of similar length several times a second, and some 62 prefixed frames of similar length about once a second. We can discard those from our capture to make it a bit easier to look at. Then there's this weird prefix - aa 06 - that does not have a consistent frame length. It only shows up every so often - for example, there was a gap from 11:54:39.803 to 11:56:50.722 where no aa 06-prefixed frames were seen. If we zoom out, we notice that there are bursts of aa 06 activity that reliably start about every 2.5 minutes - 150 seconds - which fits our criteria: less frequently than every few seconds, but more frequently than every 5 minutes, and 2.5 minutes is also an even divisor of the 5-minute interval that varserver updates on.

Looking at the frames themselves is a bit overwhelming because they're much longer than the aa 01 ones we looked at before. We see a few distinct lengths: 10 bytes, 45 bytes, 52 bytes, 92 bytes, and 136 bytes. Each of those is probably a different kind of request or response. We can cut down our focus to just one "burst", start to end, and make some inferences about it based on the shape of the system: my system has 12 panels, for example, so we expect to hear 12 microinverters tell us their state.

If we just look at the pattern of the lengths in the burst that starts at 11:56:50 AM, we see a pattern:

(W is main board to LIB; R is LIB to main board)

W 11:56:50.7  45 bytes

R 11:56:50.9  10 bytes

R 11:56:51.8  136 bytes
R 11:56:52.0  92 bytes

W 11:56:52.0  45 bytes

R 11:56:52.2  10 bytes

R 11:56:53.0  136 bytes
R 11:56:53.1  92 bytes

([45 + 10 + 136/92] pattern repeats 10 more times)

W 11:57:10.5  52 bytes

R 11:57:11.1  10 bytes

The short 10-byte frames are identical every time.

If we look at those 45-byte, 136-byte and 92-byte frames as hex dumps, something will jump out at folks who have spent way too long staring at their microinverter (MI) serial numbers: the MI serial numbers are visible in the raw hex of the 136-byte frames! It's always hanging out at bytes 35-41 of the 45-byte frame and bytes 29-35 of the 136-byte frame. That turns out to be packed binary coded decimal format.

So pretty clearly, the 45-byte frame is a request frame from the main board to the LIB saying "hey, please poll this MI now" and the 10-byte frame is an acknowledgement that the command is received; the 136/92-byte frames are telemetry from the 12 MIs in some format.

The 45-byte request frame from the main board to the LIB looks something like this:

aa 06 00 00 80 25 01 01 de af PP PP PP PP 00 02 SS SS 00 1b 07 22 01 01 6a fb 60 02 00 19 01 01 05 00 08 12 20 XX XX XX 17 00 00 RR RR

Several redactions here: 0xdeafPPPPPPPP is the PLC domain, where PPPPPPPP is a fixed hex value derived from the PVS's serial number, SSSS is a checksum over some bytes inside the frame, XX XX XX are the middle digits of my microinverter serial numbered in the PVS as E001220XXXXXX17, and RRRR is the CRC-16 checksum.

Here's a pair of redacted 136-byte and 92-byte frames from today:

aa 06 00 00 81 80 02 00 SS SS 00 b6 07 23 80 01 6a fb 60 02 00 19 00 01 01 03 00 00 55 12 20 XX XX XX 17 00 00 80 00 11 35 02 00 00 00 88 00 09 07 09 00 00 00 QQ QQ QQ QQ 5c 0d 42 48 YY YY YY YY YY YY YY YY YY YY YY YY 00 ZZ ZZ ZZ ZZ ZZ ZZ ZZ ZZ ZZ ZZ ZZ ZZ ZZ 00 53 53 75 6e 50 6f 77 65 72 de af PP PP PP PP 01 00 02 00 00 00 00 00 72 00 72 03 00 30 25 00 05 46 4e d9 00 00 0a d8 cb fd 47 53 00 03 d2 RR RR

aa 06 00 00 40 54 60 00 0c b7 cc 00 00 d4 83 00 00 11 04 00 00 00 00 00 00 00 00 05 6f 61 90 00 00 0e 01 3d 05 04 00 15 01 6a fb 1f 1e 00 e0 00 20 00 00 00 00 00 00 00 00 00 00 78 00 10 07 00 00 00 00 00 00 00 04 00 01 00 02 00 de af PP PP PP PP 02 00 00 00 6c 01 01 00 RR RR

Some more redactions: QQ QQ QQ QQ is some other fixed ID I haven't sorted out yet; the YY and ZZ bytes are seemingly the panel (Q44M...) and AC module serial numbers - they aren't always present.

From here, we get into the messy part. The fastest way to figure out all the fields in the frames is to store the frames and real-world data (e.g. power/current/voltage for each MI from varserver) to build a corpus, then use variances in the real-world data to line it up to variances in the frames. This can be done by hand; some fields are easier to discover than others. But this is the kind of problem LLMs excel at when given a quality corpus.

That means we need to capture a good variability of things we believe to be in the underlying telemetry - varying power, current, voltage, time of day, and so on. A few 15-minute captures on different days at different times of day are enough to sniff out most of the fields. We also don't have to understand the entire contents of the frame to use it to extract useful telemetry: some bytes won't correlate because we don't have access to their underlying data anywhere else.

If you use the statistical approach, it's important to be wary of spurious correlation. A quality long-term corpus largely avoids it. Nevertheless, it's worth doing "hold-out" tests where you keep frames out of the corpus and see if the predictions about the decoding hold up independently. You should also do some sanity-checking by hand.

The plus side of the LLM-statistical approach: it finds fields in units that would not be obvious at first glance even if we knew the correlation was high. For example, lifetime energy is displayed in the PVS as kilowatt-hours; in the telemetry, it's reported as millijoules, a scale factor of 1:3,600,000,000 - not one I use every day.

Goodies that fall out of the corpus with this approach:

  • From byte 16, 6a fb 60 02, as an unsigned integer, 1794859010: UNIX fans will recognize this as epoch time for Monday, November 16, 2026 at 11:56:50 AM Pacific time.
  • From byte 29, 12 20 XX XX XX 17, the MI serial number in BCD
  • From byte 37, 80 00 11 35 02 00 00 00, the MI hardware part number (800-01135-r02)
  • From byte 61, the panel serial number (if present)
  • From byte 74, some other kind of serial number or part number
  • From byte 89, 53 75 6e 50 6f 77 65 72 - ASCII "SunPower"
  • From byte 97, de af PP PP PP PP - the PLC domain
  • From byte 105, 02 - the MI's logical address on the PLC network. varserver numbers the MIs differently: this one is /sys/devices/inverter/6
  • From byte 117, 25 - MI temperature; decimal 37 - 37°C
  • From byte 119, 05 46 4e d9 - operating time (it only counts while the MI is powered, so it stops overnight); decimal 88,493,785 seconds; about 1,024 days of operation.
  • From byte 125, 0a d8 cb fd 47 53 - lifetime energy; decimal 11,926,251,587,411 millijoules = 3,312.848 kWh

So oddly, there's an entire large frame that tells us almost nothing interesting - temperature and lifetime energy are about it.

Turning to the 92-byte frame:

  • From byte 6, a strange one that makes correlation challenging: the low byte of AC voltage in millivolts; the high 3 bytes are from byte 131 of the larger packet! Here, 00 03 d2 in the larger packet and 60 in the smaller, 00 03 d2 60 = integer 250,464, so AC voltage of 250.464 volts
  • From byte 7, 00 0c b7 cc - another tricky one: inversely correlated with AC frequency, it's "ticks per AC full-wave at 50 MHz", so 833,484 ticks = 59.9892 hertz. One assumes there's a 50 MHz clock this draws on somewhere.
  • From byte 11, 00 00 d4 83 - DC volts in mV, decimal 54,403 = 54.403 volts
  • From byte 15, 00 00 11 04 - DC current in mA, decimal 4,356 = 4.356 amps
  • From byte 41, 6a fb 1f 1e - another epoch date that changes on occasion, here same-day 7:19:58 AM local time
  • From byte 74, 02 - our MI's logical address again
  • From byte 76, de af PP PP PP PP - our PLC domain again

The 52-byte frame is a bit of a mystery - it has the PLC domain but no MI address. We'll just assume it's a bookend on each MI polling sweep for now.

So, in all, some solid and precise data, and a lot of other bytes that probably mean things that we can't correlate to information available via the API and other observations.

That's some of what we can learn from watching and listening. The next step will be standing in as the main board and sending our own fabricated polling frames to the LIB, so we will pick up there in the next post!

(postscript: I'm sure I've made a mistake or two here, so I'll probably have to do some editing to the post - will note edits at the end here. could revise forever - at some point, gotta just send it!)


r/SunPower • • 9d ago

App still down.

Post image
10 Upvotes

No data coming in.


r/SunPower • • 9d ago

App Still Not Right

2 Upvotes

So after last weekend's SunStrong App crash, the app came back on Sunday. But.... my battery reading is stuck on the pre-crash reading and no longer reporting. Also the green dot on the home screen has been replaced by an orange dot which leads me to believe something is amiss there. My Sunflower App keeps chugging along just fine.


r/SunPower • • 10d ago

What actually made you switch solar software last time?

0 Upvotes

Not the sales pitch, the real reason. Price went up? Missing integration? Support stopped answering? Crew just refused to use it?
And what did you check before picking the replacement?


r/SunPower • • 11d ago

Unable to login or reset password - anyone else?

4 Upvotes

SunStrong app. If I login it says invalid email or password. If I try to reset the password it says unable to reset.

Anyone else??


r/SunPower • • 13d ago

Dead Battery But Panels Still Work

Post image
2 Upvotes

Been dealing with trying to find a tech that can fix this issue, I live in Va. Battery is completely dead and I bought a special charger to charge it bit last tech said it was a sunpower software issue. Will somebody please help me here this has been so frustrating called Sunpower 3 times and they keep giving me numbers to companies that cant help.


r/SunPower • • 16d ago

Solar installation ransome

2 Upvotes

I installed solar system and the company didn't pay the installer, my account has been locked out with a message saying we want our money. How can I change the admin password so the installer doesn't have access as I landed in between company and the installer and I cant get energy even do I payed for it?


r/SunPower • • 19d ago

has anyone's PVS6 updated itself on cellular? any ideas on how to force firmware update?

3 Upvotes

Previous owner has system on cellular the entire time. PVS6 is on SWVER: 2022.10, Build 61120. I'm wondering if this is why the PVS6 never updated? Since dl_untransmitted: 597102 (hasn't changed overnight)

eMMC seems to be fine? dl_flash_avail: 62648

I connected the PVS6 to my network last night.


r/SunPower • • 21d ago

Bought a house with a SunPower system. What next?

5 Upvotes

I’m in Ohio and my house has a 3 year old set up. The seller was not the installer and never used them. I have had no luck figuring out how to do anything with this and need some step-by-step handholding.

Please ask me any questions that will help advise me or get this thing running.

Thank you so much! I’ve been unable to find any local solar companies that can help.


r/SunPower • • 21d ago Bravo

Solar Monitor 60 second setup

25 Upvotes

Quick explainer video for all the new orders on the way. Leave a comment if you have any questions!


r/SunPower • • 22d ago

Love the New look of the Sunflower App!

Post image
13 Upvotes

r/SunPower • • 24d ago

sunstrong app shows no home consumption

5 Upvotes

what simple reset fixes this. not just today but month and year view show no consumption -- yet the net grid usage is correct (I think)


r/SunPower • • 25d ago

Looking to replace sunvault sunhub+

2 Upvotes

After multiple resets and recoveries over the last 4 years and finally hitting a wall after trying all sorts of hard reset procedures in the last 3 weejs and unable to get my pvs6 and battery to cone back, I'm thinking of replacing my sunvault system for a tesla powerwall3 setup. The cost will be 4x what it would cost to get a sunpower experienced tech to replace pvs and gateway to bring it back to life but maybe worth it to avoid recurring trouble in the future. Has anyone gone done this road? What has your experience been like? Pros and cons?


r/SunPower • • 25d ago

Solar Battery Disposal

1 Upvotes

Does anyone know who to contact to dispose my dead solar batteries?


r/SunPower • • 26d ago

Anybody have any SMA or Sunpower STP 24000s collecting dust? Out of warranty and need 2 or 3 replacements

2 Upvotes

Anybody have any SMA or Sunpower STP 24000s collecting dust? Out of warranty and need 2 or 3 replacements


r/SunPower • • 26d ago

SunVault Recently Stopped Providing Backup Power During Power Outages

2 Upvotes

We have a 9.57 kW system with a 19.5 kWh SunVault (single enclosure) that was installed in April 2024.

I run the SunVault in Self Supply mode, and everything was working fine until a recent power outage when the battery backup failed to kick in. Previously, the SunVault supplied backup power during outages.

Today, I decided to check if the backup power would kick in by manually shutting off power at the main panel. No luck. When I shut off power the main panel, the SunVault stopped charging, so I guess the panels shut off, as well. The exclamation point LED on the front of the SunVault was on and red.

After I switched the main back on, I went ahead and manually reset the battery, and everything is working as before.

I am wondering what I can do that might "fix" the system before calling in a technician to fix the problem. Even if I can't fix it through flipping breakers, etc., I figured it would help to do some early troubleshooting to help whoever I bring in to find the source of the problem as quickly as possible.

We are in the SF Bay Area.

Thanks in advance.


r/SunPower • • 26d ago

Anybody have SMA/SPR STP 24000s laying around?

2 Upvotes

r/SunPower • • 27d ago

Free PVS5X

3 Upvotes

Anyone want this thing before I throw it out? I had enphase replace mine in an attempt to see if I can get individual panel monitoring.

I'm in Queens, New York.