r/lowvoltage • • Oct 13 '21

Welcome! Rebooting this sub.

102 Upvotes

Greetings!I asked to be made a moderator of this sub since it had very little recent traffic and seemed to be abandoned by the previous mod. Since it was configured as a restricted sub, moderator activity is required to allow new people to join. Honestly I was surprised to see a somewhat dead sub on this topic given the popularity of low voltage wiring at both the professional and consumer level.

With that in mind, I changed the group to public which will increase the exposure and ability of people to join in on conversations. Over the long term we can decided if this is a better configuration as it does carry some moderation load and potential for poor content at times. I would love to hear feedback on this setting.

There is also the question of professional vs amateur/consumer content. Given the broad name of this sub it is possible that it might mature into a couple of different subs focused on those areas, but as of yet there isn't sufficient traffic to merit that.

A sub like this is only as good as the people that contribute to it, so it is really in the hands of everyone who has a the skill and passion to help out. I would like to add a few additional moderators in the near future, so if you have an interest in that, reach out to me.

A few quick notes about me - I'm an electrical engineer, having done a mix of hardware, firmware, and software in my career. Currently I'm the CTO of a technology healthcare company and have previously founded and sold a few technology companies. I am not a professional low voltage designer or installer, perhaps more of an advanced amateur. I have a passion and interest in low voltage wiring and have had a reasonable amount of experience over the last 20 years doing low voltage wiring both for my own houses as well as friends. I recently completed building a new house that has a tad over 21 miles of wire and fiber in which I did the design, install, termination and configuration. It was an awesomely fun project that provided lots of opportunity for learning. For those that are interested there are some notes in a build thread I have maintained on garagejournal. (see https://www.garagejournal.com/forum/threads/jeffs-mountain-side-shop-portland.409988/)

I'm thrilled to see some great questions, conversations, tips, guidance and learning opportunities. Feel free to reach out with any concerns, ideas, criticism, and suggestions.

Jeff Sponaugle


r/lowvoltage • • 1h ago

Hiring

2 Upvotes

Anyone in the DFW looking to get into data cabling. My company is looking to train someone to take over our cabling department. We have a small 2 man crew but we have plenty of work and we need to train someone to take over this division within the next few years. There would be some travel within the state of Texas. We haven't had to hire anyone in years so we dont know what the pay range should be but we are thinking $25-$28hr to start. Obviously pay range would change when bumped to head the division and there would be bonus opportunities in place.


r/lowvoltage • • 13h ago

Public women's restroom emergency bell maintenance in Korea (CR2025 swap & police check) - how do you handle this in your country?

Thumbnail gallery
19 Upvotes

Did maintenance on 10 public women's restroom emergency bell sites today.

Swapped out dead CR2025 coin batteries in the older square Syscall call buttons. A few units were completely worn out, so I replaced them with the newer round black Syscall CALL buttons. Since the size is different, I had to take off the old protective cover to get them mounted cleanly. Out of the 10 sites, 1 receiver unit was faulty, so I pulled it and sent it in for A/S (repair).

Before touching anything on site, there's a strict routine here:

  1. Call the local police dispatch / control room first to let them know I'm testing the bells so a patrol car doesn't get rolled out.
  2. Knock on the women's restroom door before opening it, and put up a "Telecom Work in Progress" A-frame sign right outside the entrance before starting.

Just curious, how do you guys handle jobs like this in your country? Any specific rules before testing police/emergency bells or working inside women's restrooms?


r/lowvoltage • • 5h ago

Potentially taking over smaller Telecom Business

Thumbnail reddit.com
1 Upvotes

Cross posting over here since we do a fair bit of cabling and there might be some insight from here!

Thanks


r/lowvoltage • • 1d ago

Guy doing a side-quest: Inspecting how correct a tower is in a game

26 Upvotes

r/lowvoltage • • 1d ago

How we set up a Fluke CertiFiber Pro before fiber testing in Korea. What standards and ref methods do you use in your country?

Thumbnail gallery
14 Upvotes

Took a few shots this morning before running certification tests on an OS1 singlemode indoor run with a Fluke Versiv (CertiFiber Pro).

Here is our usual pre-test routine in South Korea:

  1. Clean every SC connector end-face with a cassette cleaner and alcohol before touching the reference port.
  2. Set reference in Smart Remote mode using the 1-Jumper method (today's ref read -3.41 / -3.70 dBm at 1310nm and -3.47 / -3.32 dBm at 1550nm).
  3. Select Korea's "Emblem Indoor Fiber SM" test limit (our national high-speed building certification standard). Both 28m and 34m runs passed today at 0.35 to 1.40 dB loss.

I'm genuinely curious how techs in other countries set this up. Do you mostly run 1-jumper, 2-jumper, or 3-jumper referencing? And what test limit standards (TIA-568, ISO 11801, or something local) do your inspectors require?


r/lowvoltage • • 1d ago

Cat 6 Direct Burial (Heavy Jacket) Screw-In / Cable Clamp suggestion

1 Upvotes

What is the best screw-in/cable clamp to use with GearIt Direct Burial, Cat 6, 23AWG Pure Copper Shielded FTP, Waterproof UV-Resistant LLDPE, PoE cable. The GearIt site does not publish actual cable dimensions. Also, contacting their Customer Service does not provide an answer.

I have a lot of Cat 6 to install on exterior clapboard siding as well as interior so I am hoping to get some feedback from people who have had a good experience with a certain clip or clamp.

FWIW: on amazon i have considered....

THE CIMPLE CO Single Cable Clips with Screws - 1/4 Inch Coaxial Cable Clamps Outdoor - Exterior Cord Management for Coax, CAT Ethernet, Electrical Wire - Screw Clamps for Wires - 100 PCS, Black

https://www.amazon.com/dp/B01MT1T425/ref=sspa_dk_detail_2?pd_rd_i=B07C11GLY4&pd_rd_w=W6nMl&content-id=amzn1.sym.4adc092d-0184-45e6-8bd0-773f48fbf8ff&pf_rd_p=4adc092d-0184-45e6-8bd0-773f48fbf8ff&pf_rd_r=40Q3F40CTAVNFHNEE9QS&pd_rd_wg=NbKSP&pd_rd_r=422a8ca3-cf10-4b59-bfd5-989fb0581d1d&sp_csd=d2lkZ2V0TmFtZT1zcF9kZXRhaWxfdGhlbWF0aWM&th=1

Best Connections Coaxial Cable Clips with Pre-Inserted Screw (100 Pack) – Black Single Cable Mounting Clamps for Coax Cable (RG6, RG59) and Ethernet Cable – Cord Fastener/Strain Relief Clip

https://www.amazon.com/CONNECTIONS-Coaxial-Cable-Clips-Pre-inserted/dp/B077QH8R9G/ref=sxin_12_pa_sp_search_thematic_sspa?content-id=amzn1.sym.4fc3b349-2f5a-4620-b35e-3bfc5a564f92%3Aamzn1.sym.4fc3b349-2f5a-4620-b35e-3bfc5a564f92&crid=EWMMQAHP62VZ&cv_ct_cx=outdoor%2Bweatherproof%2Bcat%2B6%2Bcable%2Bclips&keywords=outdoor%2Bweatherproof%2Bcat%2B6%2Bcable%2Bclips&pd_rd_i=B077QH8R9G&pd_rd_r=b2fcd8a9-3587-49a6-8f0d-c24f92a74974&pd_rd_w=GyaJj&pd_rd_wg=UkcXg&pf_rd_p=4fc3b349-2f5a-4620-b35e-3bfc5a564f92&pf_rd_r=JDCY58BD15HH1CJ4K41Q&qid=1795464318&sbo=RZvfv%2F%2FHxDF%2BO5021pAnSA%3D%3D&sprefix=outdoor%2Bweatherproof%2Bcat%2B6%2Bcable%2Bcip%2Caps%2C223&sr=1-4-e169343e-09af-4d41-85b1-8335fe8f32d0-spons&aref=20BwfKDrDs&sp_csd=d2lkZ2V0TmFtZT1zcF9zZWFyY2hfdGhlbWF0aWM&th=1

My first post. TIA for your feedback.


r/lowvoltage • • 2d ago

my stepson helped me pull a line

69 Upvotes

He wants to graduate HS and go into a trade school to be an electrician, I told him he needs to do some work with me to see if he likes it.

he pulled cat6 from the MDF to an office 40 feet away, drilled a hole in the top plate, cut the the hole in the wall and installed the bracket, and terminated both ends.

his keystone work is perfect. his first RJ45 was less than perfect- but it worked first try.

its the first time he's cleaned a mess with zero complaints.

kids do want more than a job where AI does the work haha.


r/lowvoltage • • 1d ago

Need some advice on reusing construction network for commissioning

2 Upvotes

A 15MW facility completing construction and starting commissioning towards the end of December. Approx 30 WAPs deployed over 200,000 square feet to support construction activity. We would expect the number of simultaneous connections to at least double during commissioning. We'd run into problems with capacity, security (currently wide open) and who owns the assets, given that it's all owned by the General Contractor. This is our 2nd project for us, our initial project was much smaller, so we opted to replace all infrastructure. Any experience continuing with the existing network? Are there firms who can review the installation to determine suitability to continue using?


r/lowvoltage • • 1d ago

3x Viking Call for Help Buttons E-1600-65-IP available Austin Texas $300

0 Upvotes

I've got 3 new in box left over Viking Call for Help Buttons. $300


r/lowvoltage • • 2d ago

These Digital Menu Displays are always a fun install

17 Upvotes

They're just plug and play. Had to replace a patch cable a few times and Troubleshoot IP mismatches but my biggest concern is the weight of these outer panels


r/lowvoltage • • 1d ago

Field Service Managment Software

1 Upvotes

So I wanted to see if anyone has tried out QuoteIQ? We currently are using Service Fusion but looking at the two and comparing them QuoteIQ looks like it may be a much better option


r/lowvoltage • • 2d ago

Bankrupt customer, what to do with equipment?

27 Upvotes

Customer paid in full, then went out of business a year later.

They owed their own employees about $2m but fled to Costa Rica with a few months of payroll.

I see the building owner starting to demolish the existing interior and throwing away functioning equipment which the bankrupt company paid for previously.

Whats your opinion on up cycling equipment?


r/lowvoltage • • 2d ago

Used available in Austin TexasCareHawk CH1000LT Intercom Headend w/ MI100LT, SBC3, CF1GLT-CC301, DM2 & PS100LT-C

0 Upvotes

Complete core electronics assembly for a CareHawk CH1000LT Life Safety Communication & Paging System. Includes the chassis and all primary internal modules, including the OEM CompactFlash system card: • Main Interface Board: CareHawk MI100LT • Processor Assembly: CareHawk SBC3 Processor Carrier Card (0722 A1) with embedded CPU module • System Flash Media: CareHawk CF1GLT-CC301 CompactFlash Card — installed • Daughterboard: CareHawk DM2 Module • Power Supply: CareHawk PS100LT-C (120/240 VAC, 60Hz, 1.6A)


r/lowvoltage • • 3d ago

Four BICSI credentials. Four years. One commitment to never stop learning.

Post image
12 Upvotes

r/lowvoltage • • 3d ago

Somewhere, a low-voltage tech is crying. Cat6A and fiber going straight to the dumpster. That's money walking out the door! Anyone know the going rate for a dumpster full?

Thumbnail gallery
108 Upvotes

r/lowvoltage • • 2d ago

Old foam can burst on a rainy day, finally got all the stains off this panel

Thumbnail gallery
0 Upvotes

had two conduits going through a sandwich panel wall on a rainy day. grabbed an old can of spray foam to seal the penetrations and it suddenly burst out everywhere across the siding.

cured PU foam on grooved metal panels is a pain to get off without scratching the paint. took way longer than the actual conduit work, but finally got every trace off and put the caps on.

not naming the cleaner I used so it doesnt look like an ad.


r/lowvoltage • • 3d ago

How does telecom sign-off work for a new building in your country?

Thumbnail gallery
9 Upvotes

r/lowvoltage • • 3d ago

Replacing a failed NVR and rebuilding a baseball field CCTV system

Thumbnail gallery
5 Upvotes

r/lowvoltage • • 4d ago

Abandoned cable in the trays: does anyone actually get paid to pull it out?

6 Upvotes

Seems like every tray you open on a refresh job is the same story. Half the bundle is runs to racks that got decommed years ago, nobody's sure which ones, so nobody dares cut anything. New runs just go on top until the tray is way past fill and the bottom layer is getting crushed.

Pulling dead cable is a day of tracing and toning for nothing anyone can see, so it never makes it into the quote. Then the next crew inherits the same mess plus one more layer.

Is mining out abandoned cable actually part of decom scope where you work, or does it only happen when an inspector or a firestopping audit forces it?


r/lowvoltage • • 4d ago

Adding a motorized projector screen to a finished community hall with no ceiling space

Thumbnail gallery
10 Upvotes

r/lowvoltage • • 4d ago

Unifi Smoke Alarm Junction Box Adapter Plate

Thumbnail gallery
0 Upvotes

r/lowvoltage • • 4d ago

Made an iPhone tool for camera layout on site walks, looking for feedback from LV techs

0 Upvotes

Disclosure: I'm the developer of Security Camera Planner.

On a site walk you scan the space with a LiDAR iPhone (Pro models), or draw it by hand on other iPhones, then drop cameras in and check coverage, blind spots and whether faces would be identifiable, including at night. It suggests fixes and makes a PDF report.

Free for one full site. Pro is a one-time US$79.99 with a 7-day free trial, no subscription. Works offline with no account, and collects no data. It gives planning estimates, not a professional survey.

https://apps.apple.com/us/app/security-camera-planner-cctv/id6836690693

For those who do CCTV installs, what do you check on a walk that a tool like this would miss?


r/lowvoltage • • 4d ago

BICSI Telecommunications Training - Earn endless CEC's

Thumbnail bicsi.org
0 Upvotes