r/networking • • 21h ago

Design Cisco shop VXLAN EVPN with OSPF underlay

26 Upvotes

Hi all

We are a Cisco Nexus shop and I’m looking into deploying VXLAN EVPN for our facility. It’s a mix of a data center and campus but all Nexus spines and leaf.

I estimate leaf count across the entire campus to be under 100 leafs worst case.

I am very into Nexus Dashboard automation but they really force you to OSPF or IS-IS underlay.

What are everyone’s thoughts about using an OSPF underlay at this scale? I wish NDFC supported BGP underlay with easy fabric.

Considering going with a 4 spine setup.

Thanks


r/networking • • 15h ago

Troubleshooting Why would I need Fluke reference fiber cables (test reference cords)?

7 Upvotes

Hi everyone,

I'm trying to understand the purpose of Fluke's reference fiber cables (test reference cords) and when they're actually necessary.

Could someone explain in simple terms why they're needed for fiber testing? Why can't I just use any regular patch cord to connect my tester to the link?

A real-world example would help a lot, like a situation where using standard patch cords instead of reference cords gave wrong results or caused a certification to fail.

For context, I'm using the Fluke Networks FTK1475 kit (SimpliFiber Pro power meter with multimode and single-mode sources, plus the FI-500 FiberInspector). I test both multimode and single-mode links.

Thanks in advance!


r/networking • • 6h ago

Troubleshooting POE devices won’t communicate over 2 injectors

2 Upvotes

Hi, i connected 2 POE adapters LAN IN and LAN IN ports together, one adapter connects to indoor video interphone while the other connects to the outdoor unit. They do not see each other on the same network, i configured the network settings correctly and even test paired them with an additional switch in between, i tried making a crossover cable between the injectors but no luck. Why is that happening?

EDIT: When i tests with a switch they connect to each other