r/solaredge • • 7h ago

SolarEdge ONE EV Charger – Works perfectly offline but won’t charge when connected to SolarEdge backend (FW 4.00.70)

1 Upvotes

Hi everyone,

I’m having a very frustrating issue with my SolarEdge ONE EV Charger and I’m hoping someone here has experienced something similar or has an idea what might be causing it.

The problem:
My VW ID.4 is detected when plugged in, and the charging connector locks correctly. However, charging never starts.
SolarEdge app shows: “Connected – Waiting for vehicle”
VW ID.4 displays: “Check charging equipment”
Charging power remains at 0 kW
Pressing “Charge Now” in mySolarEdge does nothing

Here’s the interesting part:
When I switch the charger to offline mode in the EV Setup App, charging starts immediately and works perfectly.
As soon as I enable the SolarEdge ONE EV backend again, charging stops working.
The backend connection itself shows a green checkmark, and the charger is correctly recognized by the inverter and the mySolarEdge app. The app even detects when the vehicle is plugged in.

System details:
Charger: SolarEdge ONE EV Charger
Firmware: 04.00.70
Vehicle: VW ID.4
Inverter: SolarEdge SE8K (latest firmware)
Maximum charging current: 10 A
Authorization: Disabled
Solar surplus charging: Disabled
Charging schedules: Disabled
Import limitation: Disabled

What I’ve already tried:
Factory reset of the EV charger.
Removed and re-added the charger in the inverter’s device manager.
Tested both Wi-Fi and Ethernet connections.
Tested two completely different routers (Alcatel HH40V and ZTE G5TS Pro).
Tested two different mobile internet providers/SIM cards.
Verified that both devices are on the same local network.
Confirmed successful backend and inverter connections (green checkmarks).
Verified local mDNS discovery via UDP 5353.
Checked router firewall settings and performed network connectivity tests.
Removed an older SolarEdge EV charger from the inverter’s device manager and monitoring app
None of these changes solved the problem.

SolarEdge Support:
I’ve already contacted SolarEdge Support several times. The charger has been checked and remotely reconfigured by SolarEdge technicians on two occasions.
Their Level 2 support team indicated that there may be an issue with the backend connection and asked me to check UDP ports 5353 and 7030.
However, the problem persists even after changing both the router and the internet provider. The charger continues to report its connection status to the SolarEdge app, but charging never starts.

My suspicion:
This looks more like an issue with the OCPP charging authorization, charging profiles, or how the charger processes commands from the SolarEdge backend rather than a general network connectivity problem.
Unfortunately, I haven’t found a way to access the charger’s OCPP logs myself.

My questions:
Has anyone experienced this exact behavior with the SolarEdge ONE EV Charger?
Is there a known firmware issue with version 04.00.70?
Could the SolarEdge backend be sending a 0 A charging limit or otherwise preventing charging?
Has anyone managed to access diagnostic or OCPP logs from this charger?
Most importantly, has anyone found a solution?
The fact that everything works immediately in offline mode makes this particularly frustrating.

Any technical insights or suggestions would be greatly appreciated.

Thanks!


r/solaredge • • 3d ago

Question on setup and switch

1 Upvotes

So, long story short, they sent me a compatible RMA replacement because my original unit stopped working. It looks like they've made some changes to how it operates. It's not necessarily a big deal, but based on my old setup, I'm concerned they may have cut some of the cables to length. That's why I'm trying to get the junction box cover off. Any tips here would be great.

In the meantime, I noticed something a little unusual with the wiring. There are four PV cables, and one of them runs down into a junction box. Then another cable comes out of that junction box and runs back up into the PV unit. It's possible there's a fuse in there, but from my understanding, all of this wiring should be connected directly inside the unit itself. If these two didnt go down into the junction box, I would've been done by now.

*Yes, before I touch I did massure and made sure everything was dead. I also have a tarp over the panels just incase*

Of course, I would normally just pull it out and replace it, but they sent me a compatible replacement instead, with the cables arranged differently.


r/solaredge • • 7d ago

Situazione esasperante

1 Upvotes

Impianto di 16 mesi trifase 10 kW con backup: ecco , il backup è un’agonia. Quando si stacca la corrente, entra il backup e dopo circa 10 secondi si spegne, togliendo la corrente in tutta la casa. In questi 16 mesi provato di tutto, ma proprio tutto. Di recente cambiato il backup: niente; 5 giorni fa cambiato l’inverter: niente. Con un tecnico abbiamo provato a togliere tutti gli ups che ci sono in casa, staccandoli fisicamente, e abbiamo staccato fisicamente anche le stampanti laser e 3d, ora il backup resta su per 10-15 minuti, poi salta di nuovo. Che cavolo è che crea problemi ? È possibile che un backup abbia questi problemi? Con la vecchia configurazione tesla nella casa vecchia avevo stampanti e ups e zero, ma proprio zero di questi problemi.


r/solaredge • • 9d ago

Questions about just doing the work my self

1 Upvotes

I'm currently going through an RMA for my inverter. They have already identified the hardware error and are sending me a replacement unit. From what I understand, the new unit will need to be commissioned, but I'm a little unclear on what that process actually involves.

With my older unit, I had full access and control through its local IP address. I assume commissioning is different and may require access through a front-facing console or some other interface to configure everything?

I currently don't have an installer. I recently purchased the house, and it seems the previous installer dropped out once ownership changed. They're now quoting me over $1,500 just to come out and handle the replacement and commissioning.

I understand that professional work costs money, but I'm fairly handy and comfortable working with electronics. Based on what I've seen at the inverter, physically swapping the unit doesn't seem particularly complicated. While I haven't worked on a large-scale solar system before, I've built and worked on plenty of smaller systems and professionally handle smaller electronic devices as well. I'm a firm believer in the "test before you touch" approach.

So, I'm trying to understand whether replacing the inverter myself is a reasonable option and, more importantly, what the commissioning process would involve afterward.

Also, is there a way to purchase spare parts directly so I can keep some on hand in case something else eventually fails?

I'm also interested in becoming my own installer going forward, so I'm looking for information on what that process entails, what requirements I would need to meet, and how I can get set up to handle future maintenance, commissioning, and repairs myself.


r/solaredge • • 10d ago

UK Se3680 is kaput, how long to fix?

1 Upvotes

I posted this as a comment on another sub, don't know why I didn't think to post here?!

Thoughts on the timescales quoted?

No quote yet either :(

Just as well my se 3680 inverter has died :( down 5 days now.

Just heard back from supporting installer (not original, they went bust) who took over support when my first se inverter failed, 2017.

Wasn't sure if se warranty still covered it, asked anyway.

They came back to me this morning - yes covered, yay!

I'll apparently get the latest model.

Have home assistant running and so if you have suggestions for how to get it all local, I'm all ears!

Only downside is apparently it takes 4 weeks as it's coming from Hungary!!!

Bit concerned about the quote needed for install though?!

"

The warranty replacement is in the system. I just need to review the details and update SolarEdge. They’ll then ship the inverter to us from Hungary.

I want to be upfront about the timing so you know what to expect. In my experience, the whole process can take around four weeks, including delivery and fitting. At this stage, the week before Christmas is a realistic estimate, depending on when the inverter arrives.

**I’ll send you a quote covering all the work needed to fit and set up the replacement.** Once you’ve had a chance to look it over, just let me know if you’d like to go ahead.

"

(My bold emphasis)


r/solaredge • • 10d ago

SE5000H Modbus TCP

1 Upvotes

I'm trying to enable modbus so that I can link the inverter to my home assistant. I can't seem to get into the settings. I've tried connecting to 172.16.0.1 through both WiFi and ethernet but it won't load. Yes I've toggle the switch to enable the access.

Do I need to get my installer to do this?


r/solaredge • • 12d ago

USA Think my inverter died

4 Upvotes

Sorry if wrong place. Bought a house few months back that had a solaredge setup. Talk to the solar installers and thought everything was okay. Last week it looked like like production stop, but I didn’t notice till the other day. Call the installer and was jerk around if they would fix the issue or not. Or there might be a fee if they even though it was still showing under warranty. Their reasoning is I didn’t buy the system. So now not sure what to do. I assume this is common with installers, but not sure if to go 3rd party or work with them.

It’s a ground mount array, ac coupled. Honestly, thought about seeing about just getting the part under warranty, but wasn’t sure how solaredge does that with residential customers vs installers.

As for why, looks like the solar panels are producing power, but the app shows only a few watts from each panel. The inverter outside is blinking on green. The inverter shows error : 二
Error 18xBC: Power module voltage imbalance
Reported on Nov-12-2026, 09:32:40
L)
Error 18xB5: DC/AC in-stage over voltage
Reported on Oct-4-2026, 06:24:37


r/solaredge • • 13d ago

inverter not communicating with the app

2 Upvotes

I have a solaredge inverter SE17k and a few months ago my neighbor had a delivery and the delivery van hit the fiber optic cable for the neighborhood so we were without internet for a week while it was being repaired. When we came on line again, I could no longer communicate with the inverter using the MySolarEdge app. The inverter says it's connected to my wifi network and I can see it on my router's listed devices but the MAC address is different on the router than what the inverter says it is.

I've tried reconnecting it to the router by going into wificonfig and using wps but it just continues to say 'waiting' (yes i pushed the wps button on my router). I've contacted the original installer but he's no help at all.

My inverter is old enough that there is no qr code for easy connections so i enter the info manually but it doesn't help.

Do you have any ideas what's up and how to fix it? thanks in advance


r/solaredge • • 20d ago

Schedule battery charger up to x%

4 Upvotes

Does solar edge snow setting a limit to charge battery to when charging on a schedule? Any plans to add this feature?


r/solaredge • • 21d ago

Canada SolarEdge API retired Nov. 3 2026

5 Upvotes

FFS Solaredge, why retire the API before its replacement is ready?


r/solaredge • • 23d ago

Vaillant heat pump with Solaredge inverter

Thumbnail reddit.com
2 Upvotes

r/solaredge • • 28d ago

Is SolarEdge really this bad? Any tips?

6 Upvotes

Recently bought a house with a SolarEdge system. We have a meter communication fault and cannot get anyone from this company to do anything about the open ticket, or answer the phone. And their useless chatbot wants to talk to me in Hebrew, despite me being in Northern California.

Is this typical of their customer support? Any tips on what to do here? I am new to having a solar power system and am kind of lost as to how to get this fixed.


r/solaredge • • 27d ago

All lights on, green light blinking

2 Upvotes

Anyone know what might be going on with the inverter? My power bill was high and it looks like it just stopped making electricity in the middle of the month. I tried connecting via the app but it wouldn't let me do anything once connected. I tried to power cycle the system to no avail.


r/solaredge • • Oct 27 '26

Difference readings

1 Upvotes

We just had a Solaredge system installed but we have enormous differences in readings between the Solaredge app and the official readings from our provider. Our provider’s smart meter shows for example electricity imported 21kWh, the app 11kWh exported.


r/solaredge • • Oct 26 '26

SolarEdge battery without a backup interface: a hard discharge floor and standby protection using Predbat

3 Upvotes

TL;DR: How I got Predbat, a SolarEdge inverter with a ~10 kWh battery, EDF's smart EV tariff (via Predbat's Kraken component) and a Hypervolt charger to work together without wasting money or stranding the battery. Config snippets use placeholders, with example entity names in comments.

This guide records the protections, checks and settings that were needed on one real system, and why each one is there.

Who this is for

PartExample used here
InverterSolarEdge, via the SolarEdge Modbus Multi integration (inverter_type: SE)
BatteryAbout 10 kWh (9.7 kWh usable), 5 kW inverter limit
TariffEDF smart EV tariff (night rate 23:00–06:00), rates and car slots via Predbat's built-in Kraken component
ChargerHypervolt, with charging slots set by EDF smart charging
CarAny EV whose battery level and charge target are visible in Home Assistant

Most of it also applies to other inverters and Kraken-based suppliers. The battery-floor workaround is specific to SolarEdge.

How to read the YAML: each value is a placeholder in <angle brackets>. Where it helps, a comment underneath gives an example entity name.

Problems this solves:

  • Predbat can't set a discharge floor on SolarEdge without a backup interface.
  • The battery can drop into standby if left idle at low charge.
  • Predbat doesn't see a car charge it wasn't told about, so it may export into the car.
  • EDF's car slots are priced cheaply for the whole house only if Predbat is set up to trust them.
  • Two schedulers (the car's app and EDF) fighting over the charger.

1. Battery floor

On SolarEdge, Predbat can't stop the battery discharging below a set level, so a Home Assistant automation does it instead. Predbat's best_soc_keep and best_soc_min are planning targets, not a hard floor, and set_reserve_min needs a SolarEdge backup interface.

The automation freezes the battery through Predbat's manual freeze-charge selector when it drops below about 6% between 05:00 and 23:00. From 15:00, it freezes every remaining slot up to 23:00 in one go, so Predbat changes mode, and notifies you, once instead of every half hour. Before 15:00 it freezes only the current slot, so solar later in the day can still charge the battery.

# packages/battery_floor.yaml
automation:
  - id: battery_floor_freeze
    alias: Battery – freeze at floor
    mode: single
    triggers:
      - trigger: numeric_state
        entity_id: <battery SoC % sensor>
        # e.g. sensor.solaredge_i2_b1_state_of_energy
        below: 6
      - trigger: time_pattern
        minutes: "/30"
        seconds: 5
    conditions:
      - condition: numeric_state
        entity_id: <battery SoC % sensor>
        below: 6
      - condition: time
        after: "05:00:00"
        before: "23:00:00"   # start of your cheap window
      - condition: template
        value_template: >-
          {% set slot = now().strftime('%a') ~ ' ' ~ '%02d:%02d' % (now().hour, 0 if now().minute < 30 else 30) %}
          {% set opts = state_attr('select.predbat_manual_freeze_charge', 'options') or [] %}
          {{ slot in opts and ('+' ~ slot) not in opts }}
    actions:
      - repeat:
          for_each: >-
            {% set start = now().replace(minute=0 if now().minute < 30 else 30, second=0, microsecond=0) %}
            {% set end = now().replace(hour=23, minute=0, second=0, microsecond=0) %}
            {% set n = ((end - start).total_seconds() / 1800) | int if now().hour >= 15 else 1 %}
            {% set opts = state_attr('select.predbat_manual_freeze_charge', 'options') or [] %}
            {% set ns = namespace(slots=[]) %}
            {% for i in range(n) %}
              {% set s = (start + timedelta(minutes=30 * i)).strftime('%a %H:%M') %}
              {% if s in opts and ('+' ~ s) not in opts %}
                {% set ns.slots = ns.slots + [s] %}
              {% endif %}
            {% endfor %}
            {{ ns.slots }}
          sequence:
            - action: select.select_option
              target:
                entity_id: select.predbat_manual_freeze_charge
              data:
                option: "{{ repeat.item }}"
            - delay:
                seconds: 2

The floor covers 05:00 to 23:00 only. The overnight part is covered by section 2.

2. Avoiding battery standby

Price the first two hours of the cheap window 0.01p lower than the rest, so Predbat charges the battery at the start of the window, not the end. When every overnight slot costs the same, Predbat sees no reason to charge early. It may leave the battery idle at the floor until 03:00, and some batteries drop into standby when left idle at low charge.

# apps.yaml – no date, so it applies every night
  rates_import_override:
    - start: '23:00:00'
      end: '01:00:00'
      rate: <night rate minus 0.01>
      # e.g. 6.65 when the night rate is 6.66p
  • An override that crosses midnight works without a date.
  • Two hours is enough to fill a 10 kWh battery at 5 kW. Allow longer for a bigger battery or a slower charge rate.
  • Update the rate whenever your night rate changes, so it always sits just below it.
  • Check it on the Plan page: Chrg should start at 23:00, and the import column shows the override with an "=" marker.

3. Car configuration

Predbat needs to know four things about the car: whether it's plugged in, whether it's charging right now, its battery level and its target. Without the "charging now" signal, Predbat can plan battery exports that just go into the car, because a 7.4 kW charger draws more than a 5 kW inverter can export.

A "car is charging" sensor. This turns on when the charger has drawn more than 500 W for 2 minutes, so brief blips are ignored. It works whether the charger reports W or kW.

# packages/car_charging_now.yaml
template:
  - binary_sensor:
      - name: Car charging now
        unique_id: car_charging_now
        device_class: battery_charging
        delay_on: "00:02:00"
        delay_off: "00:02:00"
        state: >-
          {% set p = states('<charger power sensor>') | float(0) %}
          {% set unit = state_attr('<charger power sensor>', 'unit_of_measurement') %}
          {{ (p * 1000 if unit == 'kW' else p) > 500 }}
        # e.g. <charger power sensor> = sensor.hypervolt_ev_power

A new package file may need a full restart before the sensor appears. It shows "unknown" until the charger's power reading first changes, which Predbat treats as not charging.

The car section of apps.yaml:

  num_cars: 1
  car_charging_planned:
    - <plugged-in sensor>
    # e.g. binary_sensor.hypervolt_car_plugged
  car_charging_now:
    - binary_sensor.car_charging_now
  car_charging_battery_size:
    - <usable kWh>
    # e.g. 94 for a 100 kWh car
  car_charging_soc:
    - <car battery % sensor>
    # e.g. sensor.<car>_battery_charge_level
  car_charging_limit:
    - <car charge target % sensor>
    # e.g. sensor.<car>_charging_target_level
  car_charging_energy: <charger session energy sensor>
    # e.g. sensor.hypervolt_session_energy_kwh
  car_charging_energy_scale: 1.0   # 0.001 if the sensor reports Wh
  car_charging_now_response:
    - 'yes'
    - 'on'
    - 'true'
    - 'charging'

Check the car's battery and target sensors show real numbers in Developer Tools → States. They may come from two different integrations.

Predbat car switches:

SwitchSettingWhy
Allow car to charge from battery (switch.predbat_car_charging_from_battery)OffStops the house battery draining into the car while it charges
Car charging hold (switch.predbat_car_charging_hold)OnRemoves car charging from the load history, so the house-usage forecast isn't inflated
Car energy is reported in load data (switch.predbat_car_energy_reported_load)OnCorrect when the grid meter measures the whole house, car included
Car charging manual SOC (switch.predbat_car_charging_manual_soc)OffUse the car's own battery sensor
Car Charging Plan Smart (switch.predbat_car_charging_plan_smart)OffEDF plans the car, not Predbat

4. EDF smart-charging slots

When EDF schedules the car, the whole house pays the cheap rate during those slots, and Predbat can plan around them. Predbat's Kraken component reads EDF's slots as a dispatch sensor, the same way it reads Octopus Intelligent.

# apps.yaml – rates and slots from EDF via Kraken
  kraken_provider: edf
  kraken_account_id: !secret kraken_account_id
  kraken_auth_method: email
  kraken_email: !secret kraken_email
  kraken_password: !secret kraken_password

  octopus_intelligent_slot: 're:(binary_sensor.predbat_kraken_.*_intelligent_dispatch.*)'
  # a regex, so it still matches if the sensor's numeric suffix changes

Check the slots arrive. In Developer Tools → States, open binary_sensor.predbat_kraken_…_intelligent_dispatch_…. Its state is "off" unless a slot is running right now. What matters is the planned_dispatches attribute, which lists each slot's start, end and expected charge. Times are in UTC.

Predbat's intelligent-slot switches (Predbat web UI → Config, filter on intelligent):

SwitchSettingWhy
Octopus Intelligent ChargingOnTreat dispatch slots as cheap for the whole house
Trust Intelligent slots before the car is seen chargingOnPrice future slots cheaply now, so Predbat can plan ahead, for example by topping up the battery in an afternoon slot
Confirm Intelligent slots against the car chargingOnOnce a slot starts, drop the cheap price if the car isn't actually charging. This is the safety net for slots EDF cancels or moves
Ignore Intelligent slots when car is unpluggedOnNo car, no cheap slot
Consider car full as part of Intelligent planOffDefault

With "Trust" off, future slots stay at the full rate in the plan until the car starts charging, so Predbat can't plan around them. With "Trust" and "Confirm" both on, it plans ahead and still corrects itself within about 5 minutes if EDF doesn't deliver.

What a good evening plan looks like: during the car slots, import shows the cheap rate, the battery holds steady rather than discharging, and Chrg starts at 23:00. The battery holds because grid power is cheaper than using stored energy, and because battery-to-car is blocked.

5. Lessons learned

  • Use one charging scheduler. If the car's own app has a charging schedule as well as EDF smart charging, the car only charges when both allow it. EDF then sees the car refuse a slot, may drop its plan, and can sit on "creating your plan" indefinitely. Leave the car's schedule off and let EDF decide.
  • Turning off the car's schedule without an EDF plan starts charging at once. If EDF has no plan, nothing holds the charge back, and it runs at the full rate. Wait until EDF's plan appears before removing the car's schedule.
  • Watch for Boost sessions. The charger app may show a Boost session, a bump charge outside EDF's plan. Time before the cheap window is billed at the normal rate, and EDF may not build a smart plan while a boost is active. Let it expire or cancel it.
  • Free-electricity nights. If the free window matches the normal cheap window, you don't need to change anything: the credit comes afterwards, based on what you import. A 0p override can tempt Predbat into export cycles that a charging car simply absorbs, so they earn nothing and wear the battery. If you do add one, keep the battery charging early (section 2).
  • Restart Predbat after the clocks change. After the October change, the plan showed the wrong day, an hour's offset and a stale start time. Restart Predbat on its Dash page fixed it.
  • Predbat only knows what apps.yaml points it at. Having data somewhere in Home Assistant isn't enough: a car schedule set in the car's own app, for example, is invisible to Predbat.

6. Setup checklist

  • ☐ Battery floor automation installed and reloaded (section 1)
  • ☐ Early-charge override set just below your night rate (section 2)
  • ☐ binary_sensor.car_charging_now exists and reads off or on (section 3)
  • ☐ Car section of apps.yaml filled in, with no warning on Predbat's Apps tab
  • ☐ Car battery and target sensors show real values
  • ☐ Allow car to charge from battery: off
  • ☐ Dispatch sensor shows planned_dispatches when the car is plugged in (section 4)
  • ☐ Trust, Confirm, Ignore-unplugged and Intelligent Charging switches all on
  • ☐ Car's own charging schedule off; EDF smart charging on

Verify on the Plan page:

CheckWhat you should see
Overnight battery chargeChrg starting at 23:00
EDF car slotsImport at the cheap rate, car load in the Car kWh column
While the car chargesNo Exp blocks; battery holding steady
Plan headerCorrect day and time (restart Predbat if not)

7. Example: a rainy day with the car plugged in

On a dull day with EDF car slots at 13:00–15:00 and from 19:00, Predbat uses the battery only for the expensive hours and lets the cheap grid cover everything else. This is the plan it produced at 12:20 on a Monday in late October, with almost no solar (0.16 kWh or less per half hour).

TimeImport rateBatteryWhat Predbat does
12:20–13:0030.39p61% → 57%Battery covers the house
13:00–15:00 (EDF slot)6.66pHolds at 57%Grid covers the house and car (about 12.6 kWh into the car)
15:00–19:0030.39p57% → 20%Battery covers the house through the peak
19:00–23:30 (EDF slot)6.66pHolds at 20%Grid covers the house and car; battery-to-car blocked
23:30–01:006.65p (override)20% → 92%Battery charges for tomorrow
01:00 onwards (EDF slot)6.66pHolds at 92%Grid covers the house and car
  • No grid top-up in the afternoon slot: the forecast shows the battery lasting until the evening slot, so charging at 13:00 would add nothing.
  • The battery never sits at the floor. Its lowest point is 20%, so there's no standby risk. That's also why charging can start at 23:30 rather than exactly 23:00.
  • Car slots are priced cheaply in advance, because "Trust Intelligent slots" is on (section 4).
  • Heavy loads change the plan. If something like underfloor heating raises usage, Predbat replans within 5 minutes and may use the afternoon slot to top up the battery.

Happy to answer questions. Corrections from anyone who knows Predbat's internals better are very welcome.


r/solaredge • • Oct 26 '26

Solar edge optimizer- Can one failure cause another

Thumbnail reddit.com
1 Upvotes

r/solaredge • • Oct 25 '26

SolarEdge authorized installer (EnergyAid/Otovo) holding my warranty inverter hostage. SolarEdge support refuses to help

2 Upvotes

Long story short: My inverter failed under warranty. An authorized installer, EnergyAid/Otovo, initiated a warranty replacement (RMA) with SolarEdge on my behalf. SolarEdge approved the claim and shipped a brand-new replacement inverter directly to the installer's warehouse. We ultimately declined to have EnergyAid/Otovo perform the physical labor repairs and since then they have been dodging us and using stall tactics. They have been holding onto our inverter since September 21, 2026 and our system has been off now longer than that.

We’ve explained this situation to SolarEdge support multiple times, and their only solution is to tell us to "ask EnergyAid/Otovo to send us the inverter." That is obviously getting us nowhere since EnergyAid/Otovo are completely unresponsive. We have explicitly demanded that SolarEdge void the RMA with EnergyAid/Otovo and open a new one to be shipped directly to us, but frontline support won't budge.

SolarEdge seems to be allowing their authorized partner to do this to their customers. So, I'm wondering, is SolarEdge trying to get out of honoring their warranty obligations by leaving us stranded, forcing us to ultimately pay for one out of pocket?

I need advice on how to get this escalated immediately.

For the detailed story: https://www.reddit.com/r/solar/s/SxgWVphzeD


r/solaredge • • Oct 25 '26

Netherlands SolarEdge home assistant integration

Post image
1 Upvotes

Are there more users having diificulties with the SolarEdge integration. The modbus integration seems to work very well.

Lots of times, all sensors are offline, and some automations then fail to operate.


r/solaredge • • Oct 23 '26

solardge se300h

3 Upvotes

How does one connect to this device?

I have downloaded the Solaredge Go app. I've put the inverter in to Wifi AP mode it connects via the QR code after that it keeps hanging on communicating with inverter...

Am I missing something?

I want to enable the modbus over tcptip

A portscan reveals port 80 an 8080 but connecting to it just hangs and does nothing


r/solaredge • • Oct 22 '26

Moved into a house with Solaredge

5 Upvotes

I recently moved into a house with a solar edge, solar panel system. I would like to be able to monitor my solar panels, but I can’t seem to log into the app because I don’t have access to the solar panel. The solar panels are not in my name and I was wondering, how do I do that? I saw on the Internet there’s a form that you need to fill out to transfer the title but it’s 100 bucks so I was wondering if there’s anyway around that or is that the easiest way to do it and would it allow me to then be able to monitor and log into my account?

Some people have told me to find my installer and contact him, but we don’t know who the installer was and we have no way of finding that out so I was just wondering how do I solve my problems and any other information or advice would be very helpful?


r/solaredge • • Oct 17 '26

Technical question

1 Upvotes

I had a se7600h wave inverter where the communication board locked up during a firmware flash. Killed the ability to communicate, the the inverter part continued to work as rated.

  1. any suggestions on how to fix the communication board. I tried getting the latest firmware that solaredge would send via email and put it on a USB. It didnt work.
  2. if I use a communication board from a smaller inverter, ie: a se3800h wave, what will happen with the clipping. The communication board has the model, PN, SN and limits of the 3800.
  3. I already have this combo running, but currently only 4kw of panels on it.
  4. can the se3800h board be reprogrammed to the se7600h limits, if so, how?
  5. where can I buy a se7600h wave communication board? Solaredge won't send me just the communication board.

I will be cross posting this msg


r/solaredge • • Oct 16 '26

USA Did You Own SolarEdge ($SEDG) During Its 40%+ Stock Drop? Investor Settlement Update

Post image
4 Upvotes

Hey guys, if you missed it, SolarEdge ($SEDG) agreed to a $55M settlement with investors over claims that it misled the market about weakening demand in Europe and rising inventory. Late claims are still being considered, even though the deadline has passed.

Quick recap: In 2023, SolarEdge continued saying European demand was strong while inventory was building. In August, 2023, the company disclosed excess inventory and slower growth, sending $SEDG down 18.3%. In October, it disclosed unexpected cancellations, and the stock fell another 27.2%.

If you invested in $SEDG in 2023, you can still check the details and submit a late claim here. 
Did anyone here hold $SEDG during that period?


r/solaredge • • Oct 15 '26

other Solar edge ownership

3 Upvotes

I became the owner of a house.
This house includes solar panels with a solaredge inverter:

I would have liked to have access to the system to be able to follow everything through the app.

However, I no longer have contact with the previous owners. Systeem :

-Panelen:
14 X Phono salar 275Wp Totaal vermogen:3850Wp
-Omvormer:
Type: Solar Edge SE 3000H

There’s no way to find or reach customer support. Any help?


r/solaredge • • Oct 15 '26

USA Resetting solar edge after a power outage

1 Upvotes

The cell link stopped working and the solaredge go app has an error where I cannot connect. I dont want to pay 600 for a tech to come out to reset it. What are my options?


r/solaredge • • Oct 12 '26

Run EV on your excess solar

0 Upvotes

We built software to automatically charge your Tesla using excess solar, with no additional hardware needed. It works with Enphase, SolarEdge, and Tesla Solar, and many other providers. We are currently pushing new features to support Nest Thermostats, batteries, and charger support. We’d love for everyone to check it out and get some feedback.

Available here