r/sprayfoam • u/OrdinaryPresent6417 • 1d ago
Spray foam insulation (open cell)
reddit.comAdvice needed see post above
r/sprayfoam • u/OrdinaryPresent6417 • 1d ago
Advice needed see post above
r/sprayfoam • u/AlexTangoFuego • 2d ago
Interesting video. I know I've always just trusted my spray foam subs. Is anyone doing a deep dive with the spray foam installations? QA/QC-wise? Talking to the sub and lead man about substrate moisture content, ambient temps, ambient relative humidity, reviewing the TDS and spraying parameters - mixing temps and ratios, calibrating the spray nozzle, etc., etc.? Vetting the training (and certifications) of the crew and spray man?
It's not like we can be in the house watching the installation either. I wouldn't go in there even completely tyvek-suited up with a backpack air-pack on.
In other words, being proactive up-front to prevent problems like these? Granted, I'm sure these types of situations are rare.
What's the appropriate level of BS "best practices" with regard to spray foam installations?
r/sprayfoam • u/empire299 • 6d ago
r/sprayfoam • u/thunderhead__ • 7d ago
r/sprayfoam • u/BuyerDistinct5901 • 14d ago
r/sprayfoam • u/TheSprayMarket • 17d ago
We see E99 come up at the shop, so figured I’d share a few things to check before assuming you need a new board.
E99 is a communication error. A loose connection or damaged cable can cause it, so start there.
Shut off and disconnect power before unplugging anything, and follow the service manual for your model.
These are the four spots to check:
Once everything is connected and the covers are back in place, power it up and see if the error clears. If it comes back, follow the next diagnostic steps in your model’s manual before buying parts.
Posting this because checking the connections first might save someone some downtime.
Disclosure: I work at The Spray Market.
r/sprayfoam • u/b1ghurt • 18d ago
Northeast Florida for location, high heat summers and humidity. New construction home, Zip R system for sheathing and roof deck, considering foam for roof deck and hot walls. What is my best route with whats out there currently?
I have one person saying do spray foam but only open cell. I have someone else saying stay away from foam in our area due to humidity/off gassing, needing dehumidifier so added costs for not a huge savings in energy bill. Research indicates open cell only with a dehumidifier but also doing a hybrid option of 2" closed to act as barrier to roof deck then open cell after. Which the open cell only person said not to do any closed cell or vapor barrier between deck and foam.
I am viewing it as the following:
Option 1:
Open cell only, spray roof deck and hot walls of attic. 1 installer says they will only do this and do not recommend closed cell at all. I feel this will add a whole home dehumidifier to the cost as well. Those systems are an additional 4-5k minimum and I don't think energy savings will ever recoupe those numbers during it's lifespan. So it's added equipment that can break or have things go wrong. Maybe it wont need to run as often and could last longer. My fear is making things overly complicated and adding in more things that can break or require more maintanence. The other side is the HVAC may not have to run as much either just to dehumidify the home so it might lengthen the life span of the HVAC and the whole home dehumidifier if working together.
Option 2:
Forgo spray foam, just install bats through the whole home. We don't have crawl or basements here so ducts run through the attic. Temps in there can get 130-140+ at times which means the HVAC might have to run harder, potentially lowering it's life span. However, we wont need the dehumidifier which makes the system a little more simple and less items to break. The downside to this is the HVAC will definetly run harder/longer, potentially on cooler days we have to make it cooler so it will run to just dehumidify the home if we don't have a separate dehumidifier. Seeing this could shorten life span of HVAC system.
Option 3:
Hybrid setup, doesn't seem popular or people wanting to do that here. But 2" closed and the rest open. The downside is if a leak develops at roof, there is no back drying like there is with open cell. Can result in rot on roof deck. Some research indicates this may be able to get away with also not having a whole home dehumidifier, as there is a vapor barrier between. Testing would need to be done to see if dehumidifier would be needed.
I'm looking at this home as our last home. Trying to build above builder grade for long term, low maintanence, effecient home. But also trying to stay budget minded as we never know what life will throw at us in future.
r/sprayfoam • u/ctprivat • 22d ago
Just got an inspection report back and received this quote.
A few things to note about my home:
- Almost 100 years old.
- 20 year old HVAC system that’s still running, but I plan on replacing before summer.
- Humidity sits around 65% if I don’t have dehumidifier running; when running it’s around 56%.
- One of our back bedrooms is warmer in the summer than the rest of the house; same thing for winter.
Apologies if I’m missing any other important information.
Thanks!
r/sprayfoam • u/BingBangBeanz • 25d ago
Does expanding spray foam work to fix these types of holes?
r/sprayfoam • u/talonkev • Oct 19 '26
I’m in the planning phase of a new construction house in Pennsylvania, climate zone 5A. The house will be roughly 2000 sq ft with a below grade poured wall basement. I’m drawn to the idea of insulating the outside of the basement to keep the concrete basement walls inside the thermal envelope. I’ve read contradicting info on closed cell spray foaming the exterior of the basement prior to backfilling. Some say it’s an all-in-one insulation and water proofer, others say you should apply a liquid waterproofing product to the exterior of the walls, then the closed cell spray foam. I’ve also read that you should place a dimple mat or similar on the outside of the spray foam to protect it during backfilling. Does anyone have experience or knowledge they can share to help me make an informed decision on how to best insulate and waterproof the basement walls?
r/sprayfoam • u/RumpledStinkSkin • Oct 17 '26
r/sprayfoam • u/Mystic-Whirlwind • Oct 09 '26
I would like to insulate a cat shelter with spray foam. I'm going to use one tote for the outside of the shelter and spray foam on the inside. I was thinking of using a second smaller tote on the inside to act as a mold to control where the spray foam goes and then remove the smaller tote when the foam sets up. I would use some plastic stretch wrap to cover the smaller tote sot the foam doesn't stick to it. I would then paint the foam to seal it. Any thoughts on whether this would work or what kinds of issues I would encounter?
r/sprayfoam • u/Emotional-Tale8710 • Oct 07 '26
E-30 reactor.
Fusion AP gun
r/sprayfoam • u/CombinationWeird1613 • Oct 05 '26
Should I be concerned about chemical exposure having a newborn? I heard that improper mixture ratios can cause lingering off gassing. The contractor said we need to leave the house for 24 hours which we will. I’m stressing because I don’t know anything about it. Looking for an expert opinion. Has anyone heard of a bad install or lingering VOC’s from spray foam?
r/sprayfoam • u/cypressblood • Oct 05 '26
r/sprayfoam • u/Present_Complex_2987 • Oct 04 '26
r/sprayfoam • u/OsteenCitadel • Sep 24 '26
r/sprayfoam • u/True_Way2663 • Sep 22 '26
I’d like to fill a small gap under a pole barn slab. It’s not a massive space so preferably a few cans of foam. Ideally the foam is strong, but I’m not overly concerned as the erosion is now under control and the slab won’t take any crazy weight in this area.
What would you recommend?
Thanks