I have had Dishy Gen 2 for over 5.5 years. It has been an amazing game changer that has allowed work from home. It has started acting up this past week, but I do not want to try to fix it because I should have fiber in about three months. I looked up the diagnostic code and asked Claude what "hardwareSelfTest": "FAILED", "hardwareSelfTestCodes": [10] was, and it didn't know. I asked Grok, and this is what it said. I hope this helps someone using AI to diagnose.
**Your Dishy has a failed hardware self-test on code 10 (`ETH_PRIME`), which points to a problem with the primary Ethernet port / link.**
Everything else in the status looks fine:
- `disablementCode: "OKAY"`
- Not stowed
- No thermal issues, motors stuck, obstruction, slow Ethernet alert, etc.
- Hardware is a `rev3_proto2`
### What code 10 means
Starlink’s internal self-test codes label **10 as `ETH_PRIME`** — the primary Ethernet interface (the data + PoE connection between the dish and the power supply/router).
Real-world reports of this code commonly involve:
- Faulty or marginal Starlink cable (most frequent fixable cause)
- Link falling back to 100 Mbps
- Intermittent or degrading connection that can eventually worsen
In some cases it has preceded a dish that later failed completely and needed replacement.
### What to do
**Power-cycle the whole kit**
Unplug the power supply for 2 full minutes, then plug it back in and wait 10–15 minutes for a full boot + self-test.
**Check / reseat the cable**
- Unplug both ends (dish side and power-supply/router side).
- Inspect the connectors for bent pins, corrosion, moisture, or damage.
- Make sure they click fully home.
- Avoid sharp bends or kinks in the cable.
**Test link speed**
In the Starlink app (or advanced/debug data), confirm the Ethernet negotiated speed is the expected full rate (usually 1 Gbps). A drop to 100 Mbps is a classic sign of a bad cable with this code.
**If it persists**
Contact Starlink support through the app and mention the exact status (`hardwareSelfTest: FAILED`, code 10 / `ETH_PRIME`). They have previously replaced cables (or the whole kit) for this issue.
The self-test failure can sometimes be present even when the service is still usable, but with Ethernet-related codes it’s worth treating seriously rather than ignoring it.