I am using a PCA9701PW on my PCB, which seems to be a normal SPI shift register. It is connected to an STM32G431. When I attempt to read it, I get ones for all 16 bits from it. I have tried all clock polarity and phase combinations, and even when I pull the Chip Select pin low to load the data into the register and reset the interrupt trigger, I get no interrupt. I have checked for shorts between all pins and there are none, I also checked that the pins are wired correctly, SDOUT to MISO and CS to CS etc. My SPI clock is at 625KBits/S. I would appreciate any ideas about what to check next, thank you.
int timeTest = 0;
static uint8_t allOnes[2] = {0xFF, 0xFF};
static uint8_t expanderInput[2] = {0, 0};
...
while(1){
if(timeTest >= 10000){
HAL_GPIO_WritePin(GPIO_CS_GPIO_Port, GPIO_CS_Pin, RESET);
`HAL_SPI_TransmitReceive(&hspi1, &allOnes, expanderInput, 2, 20);`
`HAL_GPIO_WritePin(GPIO_CS_GPIO_Port, GPIO_CS_Pin, SET);`
timeTest = 0;
}
else {
timeTest++;
}
}
...
static void MX_SPI1_Init(void)
{
/* USER CODE BEGIN SPI1_Init 0 */
/* USER CODE END SPI1_Init 0 */
/* USER CODE BEGIN SPI1_Init 1 */
/* USER CODE END SPI1_Init 1 */
/* SPI1 parameter configuration*/
hspi1.Instance = SPI1;
hspi1.Init.Mode = SPI_MODE_MASTER;
hspi1.Init.Direction = SPI_DIRECTION_2LINES;
hspi1.Init.DataSize = SPI_DATASIZE_8BIT;
hspi1.Init.CLKPolarity = SPI_POLARITY_LOW;
hspi1.Init.CLKPhase = SPI_PHASE_2EDGE;
hspi1.Init.NSS = SPI_NSS_SOFT;
hspi1.Init.BaudRatePrescaler = SPI_BAUDRATEPRESCALER_256;
hspi1.Init.FirstBit = SPI_FIRSTBIT_MSB;
hspi1.Init.TIMode = SPI_TIMODE_DISABLE;
hspi1.Init.CRCCalculation = SPI_CRCCALCULATION_DISABLE;
hspi1.Init.CRCPolynomial = 7;
hspi1.Init.CRCLength = SPI_CRC_LENGTH_DATASIZE;
hspi1.Init.NSSPMode = SPI_NSS_PULSE_DISABLE;
if (HAL_SPI_Init(&hspi1) != HAL_OK)
{
Error_Handler();
}
/* USER CODE BEGIN SPI1_Init 2 */
/* USER CODE END SPI1_Init 2 */
}