Iโd just like to open and say that Iโm not a mechanic but I am a DIY guy that likes to save money so I hope this helps some people because I couldnโt find a good guide for this. Iโm going to try to put this on some Subaru forums as well if anyone has good recommendations in the comments. Also apparently these controls are interchangeable for 2015-2017 Subaru Crosstreks but double check on that.
Long story short my cars cabin fan stopped working on fan speeds 3 and 4. On speeds 3 and 4 Iโd hear a clicking noise and couldnโt figure out what it was. Eventually all speeds stopped working all together and would get the clicking on every single one. After checking the interior fuses (fuses 27 & 28 above the OBD2 Port), replacing the blower motor resistor, checking the blower motor relay, and checking the blower motor itself was functioning correctly, I finally took out the Heat/AC Control Unit itself to see what was going on.
I found that the wire harness connector was burnt but not melted. I did talk to a Subaru technician who had seen this issue before and they mentioned that if you want to use the same connector (instead of replacing the connector with a new one) you need to make sure the contacts are tight and clean, especially that they are tight so they make good contact with the pins on Heat/AC Control Unit and donโt arc. I used some isopropyl alcohol to clean the contacts of the connector and a pick to push the contacts down so they make a better connection.
Behind the fan speed knob sits the 6 pin plug, the back of the plug has the pins and the front has a face with copper traces connecting to those pins on the back. There are three plastic tabs holding it in place. I just used a metal pry tool to VERY GENTLEY lift the tabs to take the plug out and apart, do not break/damage them as they secure the plug together for good contact. There are three parts to this plug and at its simplest itโs a metal plate that makes contact with the different pins which route varying levels of voltage/current to the resistor and then to the blower motor which make it spin faster or slower. I found that there is some sort of grease or lubricant that seems to have over time melted and bridged the connections of these different paths/pins which lead to the heating up and melting of the back of the plug in one area. All I did was use some isopropyl alcohol and cleaned up the plastic housing, connections of the metal plate, and copper traces on the face of the 6 pin plug. I also used a box cutter to gently cut and remove some of the melted plastic that had ended up on the top copper trace. Since the connections are copper on copper and thereโs friction when they move, I went to Autozone and got some battery terminal grease and applied A VERY VERY THIN layer on the copper traces the three prongs of the metal plate. I donโt want to repeat the same problem but it is metal on metal and I still want to reduce that friction as best I can. I put before and after photos and pretty much assembled it back together. Iโll post a video of it working as well in the comments if I can.
Hope this helps if anyone has any questions Iโll do my best to reply. Also posted it in r/Subaru where some people commented helpful things like using iwire Subaru to buy the wire harness connector if yours is completely melted.
https://iwireusa.com/?srsltid=AYCX9vL7brVQ9J8Wkfk02EYt0tJrCmKhSyG6QNfrOzb91eDCQt6iaDd3&_su_rec=2OTRcjWKh-rtY3pbiWVzcgfjIT6zeHcBbnvusin0SWIhrDi4uXUU1eV82Vvyo4E1nj1DoH-nsk44rj-_5jl6Tpae2yP5ury9lGvjbtNOiBbopu04hWET0rQ4cPE2VhJdggBKomWhUHueEi-Kjtt2UVYgv_AmO6cOb2WC6IYgIJDEJ8kJvZyy-op60-xldKlIn-4bTyhogTB4lMSDevYmQIiqbikAd78gutYwb9y79Uh2HmvxMmO6ZhaVHS_-xsaWgD8lMGtRRPAeFkk-X5-UcvPAiuwBID-MpF0yDPlkNVAQ8pmP4Tz0EY1SLXoSS79Ms1LLnKlNToCnvA0&_su_rec_id=8b45aca9-be71-45e5-822b-dfe306ff437e-1795111988
https://www.reddit.com/r/subaru/comments/1xzuzaq/20152016_subaru_impreza_20i_heatac_control_unit/