I am testing a 29-joint G1 model with the open unitree_rl_mjlab velocity policy in MuJoCo, inside an office twin reconstructed from LiDAR and phone imagery. The experiment also includes a Go2 with two SO-101 arms. All of this is simulation.
Walking and lower arm gestures worked in the setup, but imposing an overhead arm motion while the walking policy remained active caused falls. I reconstructed the test with the same policy/model: 12/12 flat-floor runs fell, 1.0–1.9 seconds after the arm raise began. The original runner was not saved, so these are reconstructed tests, not the original runs.
After falling, the still-active policy dragged the robot along the floor. I added a simulation guard that stops the walking policy and makes it go limp when pelvis height drops below 0.5 m. That stops this particular behaviour; it does not solve balance during manipulation.
I am treating this as a mismatch in my controller setup, not a claim that a real G1 cannot raise its arm. Mass/contact parameters remain estimates and nothing has been validated on hardware.
For anyone working on G1 whole-body control: would you start with a policy trained with upper-body motion, a whole-body controller coordinating the arm targets, or a different architecture? Are there open implementations or diagnostic tests you would recommend for distinguishing policy-distribution mismatch from bad actuator/contact tuning?