I'm sharing my experience because I couldn't find a documented solution for this exact charging problem. Hopefully, this helps someone save their controller. No photos bc im lazy and was using the phone to diagnose.
1. The symptoms
My GameSir G8+ was working normally but kept reporting critically low battery.
- When connecting USB-C, the charging LED briefly turned red, then immediately switched to solid green, as if fully charged.
- The GameSir iOS app reported both batteries almost empty (around 7–9%).
- Battery percentages wouldn't increase.
- The same behavior occurred whether the controller was extended or collapsed.
- No firmware update was available.
Measuring USB power with an FNB58
I used an FNB58 USB power meter connected between my USB-C charger and the controller to monitor its power consumption.
Before the repair, the meter showed approximately 0.081 A (81 mA), and the charging LED immediately switched to green.
This was particularly suspicious because both batteries were nearly empty, but the controller appeared to think charging was complete.
The FNB58 measures current drawn from the USB supply, rather than current flowing directly into the batteries.
Monitoring battery levels with the GameSir app
I also monitored the troubleshooting process using the GameSir app on iOS.
To connect in the mode I used, press Home + Y to activate the red-indicator mode, then connect the controller to the app.
This allowed me to check the battery levels of both halves independently and see which side was reporting that it was charging.
2. The solution
Disconnecting and reconnecting BOTH internal batteries restored normal charging!
I disconnected both batteries for a few minutes and reconnected them.
Immediately afterward:
- The charging LED stayed RED instead of switching to green.
- My FNB58 showed that USB current had increased from 0.081 A to 0.406 A (406 mA).
- Both batteries resumed charging.
- The GameSir app correctly detected both batteries and showed their charging status.
I suspect the power-management or charging circuitry was stuck in an abnormal state, although reseating the connectors may also have contributed.
I didn't tested if a full discharge would give same effect, but since some charging controlles keeps some charge at all times, and deep discharge could damage bat cells, and i wanted to continue playing No Mans Sky, i proceeded with the dissasembly.
3. How to open the GameSir G8+
Here's how I disassembled mine.
Step 1 — Remove the joystick caps and front covers
Gently pull both joystick caps off. This allows access to the removable front covers.
After removing the covers, you'll find two exposed screws on each side.
Remove these screws.
Step 2 — Remove the adhesive rubber grips
Unfortunately, some screws are hidden underneath the adhesive rubber material.
You'll need to carefully peel back the rubber to access them. I couldn't find a way to reach those screws without removing the adhesive covering.
Good news: I had absolutely no trouble reusing the rubber grips afterward!
The original adhesive remained effective, and the grips stuck back into place perfectly without needing any replacement adhesive.
Just peel them off carefully and try to keep the adhesive surface clean.
Step 3 — Disconnect the USB-C charging board flex cable
Once you've opened the corresponding half of the controller, you'll encounter a ribbon cable connecting to the USB-C charging board.
The ribbon cable uses a locking connector.
Gently lift the small black plastic locking tab upward, using a careful lever motion.
Once unlocked, the ribbon cable should slide out without force.
Do not pull the ribbon cable while the locking tab is closed. Ive pulled it. Fortunately, is still safe.
I personally hate these tiny flex cable connectors, but this one is manageable if you're careful!
On reassembly, just put the lever topmost and just slide the cable until no more movement us allowed, no strong push needed.
Step 4 — Open the other half (the trickiest part)
This is where extra caution is necessary.
There's a black adhesive label hiding two additional screws.
Carefully remove or peel back the label to expose and remove these screws.
The housing is also held together by pressure-fit plastic clips.
After removing the screws, carefully separate the housing using a thin plastic pry tool. A very thin blade could help release tight clips, but a nonconductive plastic tool is strongly preferable near the electronics.
Work slowly around the edges. Don't force the housing open.
VERY IMPORTANT — SHORT CIRCUIT RISK
There are two exposed conductive springs inside the controller that can easily touch each other when the housing is released. I dont know what data transport, but they are connected to a black and a grey cable. On another post ive read an user accidentally made a short circuit, so take the advice.
The mechanical pressure of the assembled housing normally keeps things positioned correctly. During disassembly, these conductive parts can move unexpectedly.
Also, the controller can accidentally POWER ON when the telescopic mechanism is extended while you're working on it. And it will. A lot.
A little anecdote from my repair:
I swear, I practically performed the entire surgery with the controller powered on! 😂
Not intentionally, of course. This thing has so many ways to turn itself on that every time I moved or extended something, it seemed to wake up again.
I was trying to perform delicate electronics surgery while the patient kept waking up on the operating table.
Thankfully, nothing shorted out, but I definitely wouldn't recommend repeating that part of my experience.
Before opening:
- Disconnect the USB-C charger.
- Turn off the controller.
- Avoid extending the mechanism unnecessarily. (It will)
- Keep exposed conductive springs separated.
- Avoid metallic tools near the battery connections.
- Never short the battery terminals.
Disconnect the internal batteries as soon as they are safely accessible, before continuing to manipulate exposed electronics.
Step 5 — Disconnect both batteries
Both halves contain separate rechargeable batteries with detachable connectors.
Carefully unplug BOTH batteries by their connector housings, not by pulling on the wires. Idn what order to use but ive unplugged the left first, right then. Right batt seems to be the main one. When reassembly, ive used the reverse order.
Leave them disconnected for a few minutes.
Reconnect both batteries, ensuring the connectors are properly seated.
In my case, this was enough to restore charging.
4. Important discovery about charging both sides
I also confirmed something interesting about the G8+ design.
The two halves have physical electrical contacts that connect when the controller is fully collapsed. Take some time to check its health and gently push other contacts, just in case, for loosen ones.
When extended, USB-C charges the right-side battery.
When fully collapsed, the electrical contacts allow the left-side battery to charge as well. I though was a documentation error, but this seems to be real. I dont really know why this design desition, because there are some wires plugged. Maybe the extended detection mechanism is power related?
At first, when testing after re plugging the batteries, only one side was charging after my repair.
It turned out the physical contact between both halves was incomplete.
Once properly aligned and collapsed, both batteries started charging correctly.
I verified this directly using the GameSir iOS app, which displays the individual battery states.
This is worth checking before assuming the second battery has failed.
5. Final result
| Measurement | Before | After |
|---|
| USB meter | FNB58 | FNB58 |
| USB input current | 0.081 A | 0.406 A |
| Charging LED | Green almost immediately | Red, charging |
| Battery percentages | Not increasing | Both increasing |
| GameSir app | Both batteries critically low | Both charging correctly |
| Controller operation | Working, but low battery | Working and charging |
No battery replacement, soldering or firmware update was necessary.
Disconnecting and reconnecting the batteries solved the issue in my unit.
I can't confirm whether this was a power-management reset or a connector contact issue, and I can't guarantee it will fix every G8+.
If you attempt this repair, be extremely careful with the conductive springs and lithium batteries.
I hope this helps someone else avoid throwing away a perfectly good controller!
TL;DR: GameSir G8+ showing green charging LED despite empty batteries? Carefully disconnect both internal batteries for a few minutes, reconnect them, and check the physical charging contacts between the two halves. This restored charging on my controller. I confirmed the change using an FNB58 USB power meter and the GameSir iOS app in Home + Y (red-indicator) mode.