r/HVAC • u/heldoglykke • 1d ago
Meme/Shitpost It’s raining so I Decided to work from home today.
Salvaged 21lbs
r/HVAC • u/DrPepperG • Apr 01 '26
Good evening,
I would first like to thank everyone that has already completed the new verification quiz, we've already gotten loads of approved users! (For the second question the answer is "It Depends", my testing was apparently not thorough for spell checking and mobile compatibility). That verification fix will be released once Reddit approves the update.
It has come to my attention that a former mod went a little rough with certain permanent bans that were issued. If you happened to of been caught in the crossfire please feel free to open up a unban request in mod mail. I've already unbanned multiple people.
The actions from that moderator were inexcusable and I deeply apologize that we provided such a disservice to this community.
Please let us know what else you would like to see improved in this sub.
Thank you,
r/hvac Moderation
Edit: Looks like reddit is mad at the approved user count, the verification requirement has been disabled for now.
Edit2: It's back again, I've sent in a message to reddit staff.
r/HVAC • u/heldoglykke • 1d ago
Salvaged 21lbs
r/HVAC • u/iBUYbrokenSUBARUS • 1d ago
r/HVAC • u/MaintenanceTop1664 • 1d ago
Hello! I just got hired on to a residential hvac entry level position and they gave me this giant tool list. I just want to know what tools that i’ll actually need and what tools are some what optional until I have the extra money. I’m also wondering what type of boots I should get especially with black friday coming up.. Thank you all here’s the list:
- TOOL BOX/BAG
-GAUGES R22 AND 410A
-GARDEN HOSE WITH SPRAYER DRAIN FLUSH -BOTTLE/TANK
-CHEMICAL PUMP SPRAYER
-SAFETY GLASSES
-DIGITAL REFRIGERANT SCALES
-NO LOSS SHRADER VALVE REMOVER
-THERMOMETER
-MULTIPURPOSE METER VOM CLAMP ON -THERMOMETER
-MANOMETER
-Adjustable wrench
-Pipe Wrenches (2)
-ALLEN WRENCH SET
-REFRIGERATION WRENCH
-NUT DRIVER SET
-SCREW DRIVER SET
-TUBING CUTTERS
-PVC CUTTERS
-HACKSAW/SAWSALL
-VACUUM CLEANER/ACCESSORIES
-HEAT EXCHANGER BRUSHES
-DRILL
-FLASHLIGHT
-DROPLIGHT
-EXTENSION CORD 25' MINIMUM
-INPECTION MIRROR
-SNIPS/RIGHT/LEFT/STRAIGHT
-STANDARD SOCKET SET
-6 FT. STEP LADDER PSYCROMETER
-Wire Stripers
-Wire Crimpers
-LEVEL
-WIRE BRUSH
-HAMMER
-TAPE MEASURE
-UTILITY KNIFE
-UV TEST EQUIPMENT
-ELECTRONIC CO DETECTOR
-ELECTRONIC LEAK DETECTOR
-NITROGEN TANK AND REGULATOR
-VACUUM PUMP
-MICRON GAUGE
-TORCH / TANKS - OXYGEN/ACETALENE
MEGOMETER
r/HVAC • u/chunky_guac • 17h ago
Day & NIght
PDH460000L000K1
F243750150
I’m hoping y’all can point me in a direction. This heat pump is tripping on head pressure in heat mode, but no issues in cool. There’s no freezing anywhere in the refrigerant piping. I compared the rate of pressure increase at all three stages of airflow from the ECM. The OFM is amping just shy of max. I removed ~5-6LB R410A and it still rose, only slowly (and wouldn’t cool after that of course). The subcooling goes up with the pressure but superheat remains low (5F° or less) and drops as pressure increases. I tried removing the pistons and replaced it all with a 5-ton R410A universal TXV. The problem still exists.
What am I missing? Thanks.
ETA: It’s a package unit with a nameplate charge of 13LB. I recovered 10.25LB during this latest project. I added ~2LB when I recharged it with the recovered refrigerant (it was all the R410A I had left on my van and it was late in the day…I’m not proud of that fact).
r/HVAC • u/boxingismypassion93 • 1d ago
I told customer I would fix the issue but only if I do a full cleaning service on equipment. With it being electric heating, I'm not taking my chances. They refused so I I canceled the service call. Was I right to do this to a customer?
r/HVAC • u/iBUYbrokenSUBARUS • 1d ago
So apparently the subpanel on the roof instead of having two 120 legs pulled to it they pulled the 120 and a 208. So all of these units on this roof have been running with a 214 leg and a 124 leg for two years. I didn’t think that was OK to do that but apparently it is.🤷♂️
r/HVAC • u/WrongdoerNo8 • 2d ago
Can you imagine walking into this? I mean easy full system sale but geez...
r/HVAC • u/WaywardSinner • 1d ago
This is my third residential company and I overheard they may be getting rid of people.
Started out in late 2024 early 2025 with a big company, left for a family owned, got let go because of foul mouth too many times, this is my third company and I'm honestly losing my mind.
Everyone says I do good and they like working with me but I pissed the right person off somehow and idk how I even did it.
How do I get into service, or even commercial or Industrial...residential is great but it feels like I'm drowning.
r/HVAC
•
u/SammyCarriere
•
2d ago
🤦♂️
Customer had her flue cap replaced and painted about 3 months ago, along with some other roof and gutter repairs. Fast forward to the first time firing up the furnace this season, and she notices a gas smell in the garage and what she described as “smoke” coming out of the vent.
Gas company came out, shut the furnace off, and told her to call the hvac guys.
I get there, hook up my combustion analyzer, and immediately find +0.05” WC positive pressure in the flue on an 80% furnace. Clearly restricted. Within seconds, water vapor and flue gases start pouring out of the flue into the garage, and my analyzer and personal CO monitor start spiking.
Turns out the roofers installed a cap designed for B-vent onto a single-wall flue. The pipe slid too far into the cap, essentially blocking the exhaust from escaping.
What’s scary is that a “professional” roofing company AND a third-party inspector somehow missed this. Three months later, the homeowner unknowingly fires up a furnace that could’ve killed her. Gave her a quote to replace it with double wall b vent.
r/HVAC • u/heldoglykke • 2d ago
I turned the heat on and turned it all the way up but still no heat!
r/HVAC • u/ShredDurst666 • 2d ago
Don’t think it’s supposed to do that, right!?
r/HVAC • u/Theodore36 • 2d ago
10 RTU service today
Tis the season
Happy Thanksgiving!!
r/HVAC • u/JustAnotherSvcTech • 2d ago
This was a few years ago. Cold morning in November. Got a call from the owner of a vacation home. He said his low temperature alarm had gone off & he was out of town. He gave me a code for the garage door & said go anytime. When I got there & walked into the mechanical room I saw tools scattered all around the boiler as well as pieces that had been removed. I only work on forced air. No boilers. I walked past the mess & looked at the furnace. It was blinking a code for ignition failure. I reset it & all looked normal, but no flame. I walked back outside and saw that the gas meter was off & locked. I called the gas company & explained the situation. They told me that they had turned the gas off a few months prior, but wouldn't explain why. I called the owner & he was embarrassed and said he'd call the gas company and get it turned back on. As I was getting in my truck, a van pulled up & a guy got out. I asked him if he was the one working on the boiler. He confirmed that he was. The look on his face when I told him that the gas meter was off was priceless.
r/HVAC • u/Amorbellum • 2d ago
How are you guys storing jumpers in your bag. I'd love some advice because my way is definitely not working
r/HVAC • u/Simply_Spooky • 3d ago
Welp carrier, Bryant, Amana, Goodman Variable speed all good choices
Those side discharge units are cooked lol
These all ready for scrap don't worry
r/HVAC • u/Not_A_G-Man • 2d ago
When it comes to sealing gas and drain line threads, are y'all putting dope then Teflon tape, Teflon tape then dope, just tape, or just dope?
r/HVAC • u/JuicySpark • 3d ago
Just a little more pipe dope on that union so we can all see it. lol.
He got it red tagged. The guy also managed to cause a leak in the manufacturer installed pilot tubing. lol
r/HVAC • u/cycling_sender • 3d ago
Recommended immediate replacement but didn't show actual signs of failure (dancing flames, blowback, etc. - tested with lighter w/ just blower on).
Carrier Weathermaker, 10 years old. Am apprentice, still learning, thanks!
r/HVAC • u/spawn_of_ragnar • 3d ago
Might be the worst buildup on a piston ive seen. Can only assume at install 9 years ago, nitrogen wasnt purged while brazing. Or the filter drier started puking its guts. Shes running great now though!