r/refrigeration • u/XFRLAKE • 6h ago
125Kw Pumped CO2 evap swap
r/refrigeration • u/Stock_Ear2962 • 19h ago
Couple used units me and my co worked hung today took us from 7:30-3pm to with a 30 minute lunch break. Curious how long others are taking to do a job similar to this. They are used units the customer wanted installed hence the existing shitty traps someone installed.
r/refrigeration • u/Low_Calendar_6921 • 16h ago
Just curious if low charge would cause the evaporator to ice up, specifically more than half the coil, I’m aware that you could definitely have a small portion of the coil icing up like maybe the first or second bend, but i was told by several of my coworkers that a low charge, even from a large enough leak will still result in significant icing of the coil, thanks
r/refrigeration • u/thejoyouswork • 17h ago
Most of my experience is with automotive hvac, but they've got me trying to diagnose a trailer with a thermo king c600 with two cooling zones, but I have no training and the only diagnostic equipment I have is a set of gauges that don't read correctly, so I could really use some advice from people with more experience and knowledge.
As for the symptoms: trailer wont get below 25° in either zone, according to the display the discharge pressure is 200 and the suction pressure is -4, and when i put freon in the pressures went down instead of up.
Obviously something is causing the freon to stay liquid which is making the pressures read lower than they should, but I have no idea what could be causing it. I've checked and its definitely not a restricted evaporator or an air flow issue, so my best guess is a stuck valve or internal leak from high side to low side, but I don't know enough about the system to narrow it down any further than that.
Also this is with an ambient temp of 70 and a box temp of 47. Any advice would be greatly appreciated because i honestly have no clue what I'm doing beyond the little bit I've learned through trial and error.
r/refrigeration • u/Appropriate-Unit4471 • 2d ago
r/refrigeration • u/North-Block-5273 • 1d ago
For the people that have seen what Walmart has been pushing in Canada for next year, have you considered it?
r/refrigeration • u/new-faces-v3 • 2d ago
There are also laser accurate RTUs and Chillers.
r/refrigeration • u/Jmstern1995 • 1d ago
For a WI cooler with RI doors (milk, beer, etc) what do you usually figure the load is per door being opened/closed?
r/refrigeration • u/Top-Lifeguard-6146 • 2d ago
I always wondered why US had in house Walmart refrigeration techs but Canada never did? Looks like now they do but wow why is the pay so low? That is the equivalent of a 3rd year apprentice.
r/refrigeration • u/EuphoricInterview • 2d ago
Am I the only one that hates dixell with a passion? You would think a universal XR60CX would be easy but nah. It In a fairly big Copeland box you would think it have all the parameters and instructions in the box, but it doesn’t have shit, just 2 sensors and 2 plastic clip thing. So I gotta Google all the parameters and even if I find the parameters sheet, it’s not even in order. I have to dart up and down the sheet trying to beat the time-out before I have to do this set+down and hold for 3 seconds and do it again for 7 seconds. Annoying as shit. And even more annoying is that some controls don’t even have some of the parameters listed. This sum bullshit. Spending hours to find the right parameters adjust defrost setting. And not even activating the relay for the defrost at the end of the day. And all for the low cost of 268 or whatever from United. At least I can get a bullshit Amazon one for 40 bucks that would at least have 80% of the parameters listed instead of whatever fucking thing I bought.
Whatever rant over, I’m big mad, fuck dixell
r/refrigeration • u/orfed • 2d ago
There have been some posts with some bejeweled pink 1/4 shredder valve covers….anyone got a link to purchase? Want to get some gag gifts for our holiday party this year.
r/refrigeration • u/Busy_Animator_9000 • 3d ago
I work in a cold storage facility and we had a significant NH3 leak. The leak is stopped but I can’t clear the smell and it’s reading about 18ppm. Tried just ventilation but it’s not too effective. I’m thinking of using CO2 cylinders and filling up a bunch of 50 gallon drums with salt water. Anybody else got any ideas or seen something similar?
r/refrigeration • u/DangerousRecover1049 • 3d ago
In middle of replacing a worn crankshaft due to failed rod bearing. "New?" crankshaft appears less than perfect and roller bearings are stamped CHINA. I'm backtracking through supplier- has anyone had this experience? Thought I was dealing with reputable supplier and paid just slightly less than price quoted from a Vilter direct supplier I also use...so not a deep discount kind of immediately apparent shady dealer.... trying really hard to avoid having this compressor try to self disassemble. Anybody run with Chinese mains roller bearings? (Ice arena running R-22 in Minnesota)
r/refrigeration • u/CryptoDanski • 3d ago
How do they compare to all other ones?
r/refrigeration • u/SIRxKINGxBOSS • 3d ago
What replacement digital controller are you keeping on the truck for reach in coolers and freezers?
r/refrigeration • u/voyuerstfromthetrees • 3d ago
Hello everybody!
So, this requires some context, but I’m looking for some honest opinions to inform my curiosity. My wife started a nonprofit food hub so we’ve had all these cooling needs, and I realized that our area is pretty underserved. Specifically, there isn’t a ‘little guy’ that does this on the side. For example, she paid about 600 dollars to get a thermostat replaced on a freezer in the food hub. I would have been able to replace it, but I would have been an ‘unapproved installer’ and voided the warranty on a 8K freezer.
So, it’s worth mentioning that I’m a small scale farmer and artist in the middle of nowhere that is self-employed through a ‘mixed-bag’ of ‘country arrangements’. I’m not trying to build an empire, and I’m not trying to run a fleet. It seems to me that as someone who will need 3-4 refrigerated vans/box trucks (most likely) for my farming before I retire.. I could subsidize the necessary equipment by doing small side work for: small farmers with cool bots and walk-ins, small farmers with reefer vans & trucks, and the bar/restaurant scene (Galena, IL is hard to explain there’s a pile of restaurants there and they aren’t all necessarily giving it all away to TRUE and HOBART).
It would save the nonprofit food hub oodles of money over time, too. I can also see services for walk-in coolers being viable - think push sensors and PM.
Is this short sighted? I worked with the guys that did our walk in cooler & freezer at our hub during the install and there seem to be a few large purchases and the school of hard knocks between current me and basic but meaningful refrigeration skills.
I have loads of everyday hillbilly contractor tools, just not the specialized equipment.
r/refrigeration • u/AmbitiousHead1509 • 4d ago
I’ve got 2 years of experience in residential and light commercial I’ve recently seen that Coolsys is hiring for entry level in Cali,I’ve wanted to ask a could of questions to the guys that do refrigeration,is Coolsys a good company?I’ve heard good things and bad things about them,I’ve been wanting to get into refrigeration for a while,does anyone work for Coolsys in Cali ?
r/refrigeration • u/SignificantChicken65 • 4d ago
The installer didn't cut the stub out from the evaporator suction line before brazing the line set.
Needless to say, we are installing 6 more walk-ins for them next year.
r/refrigeration • u/IrresistibleNarwhals • 4d ago
Hello everyone,
I would like to know what the opinions are about some of the monoblock brands(Zanotti, Technoblock, Rivacold, ...) running on R290.
easy to install and all but very hard to service on.
Any kinds of problems you have experienced and found solutions for?
All info is welcome!
Thanks
r/refrigeration • u/yung1goob • 4d ago
Hi guys, I’ve recovered quite alot of r12 the past year, looking to sell my stock.
to the guys that recycle here what company would you recommend I sell it to? I’m in the Midwest.
r/refrigeration • u/Celebration104 • 5d ago
Brand new rooftop condenser unit on rooftop of 9 story building for grocery store on ground level keeps cycling on and off every 5 minutes. Of the five units in the overall system the unit on the far right runs 24/7 at full speed while the units on the far left don’t appear to be running at all right now due to the cooler temperatures outside. The middle unit appears to be the one doing the cycling on/off every five minutes or so. It’s resulting in a large boom/thrusting sound as the unit turns on, which is causing a noise disturbance in my apartment, which is right below the rooftop. The landlord of the building has claimed that they have had contractors come out and say that the machine is running adequately and they can’t do anything about it.
My question is should a unit within the overall system be cycling on/off every five minutes or so when others are running different cycles?
Really needing some advice due to the noise disturbance of the machine turning on/off every five minutes.
What can I advise my landlord and super to look into with the contractors either from the grocery store - thermostat settings or the lines or something that’s causing potential short cycling or something else?
r/refrigeration • u/GingerGiraffe96 • 5d ago
An hvac question, but still trade relevant.
I’ve had it drilled into me that if an ac compressor doesn’t have a crankcase heater, or a pump down, not even an accumulator, nothing, you shouldn’t start the compressor unless it’s 55F deg outside.
My foreman says that scrolls are extremely hearty compressors, and that it’ll be fine to run at 35F.
This is on a package rtu install and commissioning. I suggested waiting to commission the cooling until the spring to avoid a potential flooded start, and he said that it would be fine.
Am I overthinking it or missing something? Any advice or experience would be helpful.
I ended up bumping/tapping the contactor 3 times to heat up the oil to get any liquid out of it before running the compressor long enough to check rotation. I know Emerson does this practice on some of their medium and low temp controllers to prevent a flooded start in the event of a lls leaking by.
*edit
Thanks for all the commenters, the Mapp torch worries me a bit about overheating, but I’m definitely going to use the heat gun method next time.
r/refrigeration • u/Yung_Presby1646 • 5d ago
Took an emergency call for a walk in cooler for a brand new customer yesterday, and found the fan cycle switch on the condenser failed. I didn’t have a replacement switch on hand so I came back today to install a new one. The digital control on the thermostat said the box temp was 62° when I arrived, but I had a suspicion the temp was off and I never verified before leaving site (I obviously should have checked it).
Came back today and found all the product in the cooler to be frozen. The digital thermostat was reading about 13° higher than the actual space temperature.
I felt so good yesterday by being able to secure a new client, and getting their equipment up and running on a weekend…