r/askaplumber • • 1h ago

How to replace this

Thumbnail
gallery
1 Upvotes

How to replace this or get it to stop leaking from the handle


r/askaplumber • • 1h ago

Working in domestic hot water and cold water

0 Upvotes

Hi, can I keep my central heating running from my combo boiler when I turn off the mains water stop cock and drain the domestic hot water and cold water while I change move a bath and sink and add some piping


r/askaplumber • • 2h ago

Any idea what’s the exact brass fitting?

Post image
1 Upvotes

It’s to make a pneumatic launcher. Some sort of water pressure regulator?


r/askaplumber • • 3h ago

What would I use to cover this?

Thumbnail
gallery
1 Upvotes

Hi all,

We've retilled the bathroom and shower and replaced the shower. The original tiling and shower was quite thick so now that we have the new fittings they will leave a gap to the tile as pictured. What can we do/what do I search for to cover the pipe? Thanks in advance!


r/askaplumber • • 5h ago

Replaced the wax ring and shimmed my potty, it will rock slightly if I go crazy on it but, normal use has no rocking. Should I be worried about a compromised wax ring?

2 Upvotes

Is rocking of the toilet okay, as long as it takes a extreme about of effort to do so?


r/askaplumber • • 5h ago

Capping old hot water and discharge line for DW just above floor?

Thumbnail
gallery
1 Upvotes

Hey all.

I want to reroute my DW plumbing to kitchen sink plumbing after the DW failed and actually caused a flood into basement which insurance is going to take care of. I want to cap the old lines before rerouting gets done. They will drill holes through my corner cabinets to get to sink cabinet.

The HW line for my DW came from the utility room in the basement. It ran up from HWT, across ceiling and below the subfloor and then straight up to the DW. Discharge drain line is also below the DW. There was no p-trap there. The utility room is unfinished and when you get on a stool you can see between the subfloor and ceiling. You can see the supply line comes down from the DW space above then slopes down to turn 90 degrees up T to the HW line. And the drain pipe runs to the wall and then goes down behind the shower in my basement bathroom.

As these are above my basement shower, they are inaccessible from below. But, from above I am wondering if in order to properly cap them, does the subfloor in the DW cabinet space need to be cut into so the plumber can cap it below the kitchen floor level. Right now it actually is capped from the failure that occurred a few months ago (plumber did it). Not only did the intake for the DW fail but the shutoff valve failed and allowed water to continue. But it and the drain line are sticking 3” out. The same plumbing company that did the new shutoff sent a different guy for a quote and he said he needs a flooring guy to remove all that tile and then cut of the subfloor out. Then the plumber can cap just below. Then flooring guy come back and re-finish the floor with new tile and bring it level to kitchen floor. Right now the DW space is like 1 cm below kitchen floor. Plumber said he doesn’t want the lines capped above the floor because we’ll have a hard time finding a DW that will accommodate those things sticking out.

Now, why can’t a plumber cap say like 1” above the floor? Does that seem feasible? And for the plumbers out there that have experience installing many DWs, does it seem like models these days wouldn’t clear those lines if they were sticking out 1”?

Also, ideally, I would like the HW line to be capped right at the point where it T’s with the other HW line between the ceiling and subfloor, which is above my basement shower. Right beside and above the shower door is a bulkhead where that dark red steel beam runs (might notice in one of the photos). The contractors that are eventually fixing the damage in my basement and the bathroom there have to do some door trim work and the trim does connect at a couple points to the trim that has now been pulled off. I am wondering if they have to cut open the bulkhead for some reason to do that. If so, then I’m wondering if they can just cut the length of the bulkhead with a wide opening and see if someone can stick their head and arms in and reach the two above mentioned HW lines connect. That line is 20” away from the centre of the bulkhead. But I don’t know if the steel beam is in the way. Capping at the T gives that peace of mind instead of capping at the existing spot under the DW cabinet as HW will always run up that capped line.

 

TLDR:

Anyway, long story short, do you think it’s feasible to have that HW line and discharge line capped about 1” above the floor instead of the 3” they currently are? Can most modern DWs fit over that?

 

Thanks for the help and sorry for all the text and photos. Didn't know how much detail I'd need to give.

 


r/askaplumber • • 6h ago

Does this look closer to acceptable?

Thumbnail
gallery
21 Upvotes

The other day I posted here asking for advice about a drain for a laundry sink I extended. Thank you all for the feedback on that post. It was a big learning experience for me. I think I addressed mostly everything

I raised the AAV 6” above the rim of the sink

Used a sanitary tee on the AAV

Added pipe support

Added a backwater valve

Added a clean out

Added a board on the bottom to mount everything to

Flipped the ball valves around right side up.

Went from a 45 to a 90 where it connects to the drain.

I know it will never look great but let me know if I should fix anything else before gluing it all together. Thanks again


r/askaplumber • • 7h ago

where to drill hole for drain saddle

Post image
0 Upvotes

i’m installing a water filtration system that has a drain tube that needs to connect to the drain pipe. where should i drill the hole to place the drain saddle?


r/askaplumber • • 7h ago

Plumbing under the sink seems off

Post image
17 Upvotes

My family and I just moved into a new place and the plumbing under the two bathroom sinks seem off. I've never seen corrugated pipe used and the bend looks super low to me, but I work with tiny wires not pipes. Am I tripping or is this not right? Also the sink very easily fills with water when the plunger is open, so that also threw me.

Again, not my area of expertise, but this seems off.


r/askaplumber • • 8h ago

Identify the Manufacturer?

Thumbnail
gallery
0 Upvotes

Hey all- leaky shower head or tub spout when I use the diverter handle in the middle. Is anyone able to identify the manufacturer of this 3-handle tub/shower valve assembly?

Water drips consistently and indefinitely after the unit is shut off, as far as I can tell when the water is running there is no drip from the ‘off’ portion of the assembly.

Thanks!!


r/askaplumber • • 8h ago

Will a Booster fix this?

0 Upvotes

We have a house with basement, water pressure is fine in the house. Water pressure tank is in the basement, along with tank less heater. Over our garage we have an apartment with kitchen & bathroom. The water pressure up there is very low and it takes a long time to get hot water, too.

I've been wondering if a water booster would help fix this issue. If there is something more appropriate for this kind of problem, I'm open to suggestions! Thank you in advance!


r/askaplumber • • 8h ago

Combi boiler mains flow rate

0 Upvotes

I am considering installing a combo boiler to replace a very old tank and shower pump system in a small 2 bedroom/1 shower room top floor flat. At the moment I am heating ups water tank twice a day and it seems like a waste for the small amount I use.
I have had 2 different plumbers round. Both ran the kitchen tap and said it’s is water flow would be fine for a combo boiler but they didn’t use anything to actually measure it.
However, I have measured flow rate myself and it is only 6.7 L/min which I’ve read is too low for a combo to work properly.
I don’t want to go ahead with this and find the shower pressure is terrible. And I don’t interest why the plumbers are telling me it will be fine.
There is an options for a mains water pump I suppose but I’m concerned that would be very noisy.
What should I do?


r/askaplumber • • 9h ago

Sewer Odor coming from underneath vanity sink

Thumbnail
gallery
19 Upvotes

My husband replaced the sink in our powder room. It was a pedestal that he removed and replaced with this vanity. After removing the pedestal sink, but before placing the vanity, (we had a couple days in between) we started to notice a smell coming from the pipe out of the wall.

Once replacing the sink and connecting the vanity, the sewer smell has continued. It’s coming from under the vanity in the cabinet. It is intermittent, but persistent over several weeks. My husband has disconnected and reconnected everything and assured me all the seals are tight. Any ideas?


r/askaplumber • • 10h ago

Water coming out of main stack?

Thumbnail
gallery
2 Upvotes

So. Two weeks ago a downstairs toilet wouldn’t flush at all and the main drain had backed up. So call a plumber. They auger the main drain twice (first time they left without checking to see if the toilet actually worked 🙄). Yay toilet now works. Today there’s been rain all day which I mention as when the main drain backed up it was the same thing where it had been raining. Go downstairs and step right in dookie water. Seems like the water is seeping out this seam here? And yet the main drain is dry. What could be going on??


r/askaplumber • • 10h ago

Gas Regulation?

2 Upvotes

Every time i try to light my stove, the gas seems to come out way faster than I previously remember and it's hard to get going.


r/askaplumber • • 11h ago

Freestanding Tub leak

Thumbnail
gallery
1 Upvotes

I bought this house 7 years ago. It had been remodeled from the ground up. New wiring and new pipes supposedly. Along the way we have found some shortcuts that were taken. This one appears to be one of the more costly ones. We noticed water pooling around the tub during the kids’ bath time recently. At first I thought it was that they were splashing water outside the tub. It was a fair amount of water but still I was able to clean it up with a towel. In further inspection however it turns out the drain doesn’t align with the drain pipe properly and a flexible tube was installed to connect the tub drain and the main drain. This tubing appears to have a crack in it. I discovered this after lifting the tub up to have a look.

How hard does it look like it would be to replicate this it’s a new piece of flexible pipe to get the tub working again? It’s going to be several thousand to route the pipes properly it would seem. But it looks hard for anyone to get under there and maneuver new flexible tubing into place also. Appreciate any ideas.


r/askaplumber • • 11h ago

Mystery pip running through shower wall

Thumbnail
gallery
9 Upvotes

Does anyone know what this pipe might be? I’m demoing our bathroom and found it. It is running through a wall that divided the shower and tub. Above it is attic space, below is a crawl space. The bathroom is located in an addition that was added to our 1948 house in the 80s or 90s.

There is radiant heat in the attic in this part of the house.


r/askaplumber • • 11h ago

Pressure regulator

Thumbnail
gallery
1 Upvotes

This is on a house built in 2024. We did inspection before purchase and the fact that the pressure regulator valve is not positioned correctly was noted on inspection.

I don’t know much about plumbing but have struggled to find a plumber that will take the job on. I live in a rural area in Missouri and I had a plumber come look at it but he has not gotten back to me for over a month.

We do not have any pressure problems in the house even the plumber was surprised by that.

Anyways I am considering a DIY fix due to above and would appreciate advice. See the attached pictures.

Having the original plumber fix this problem is not an option cause the builder no longer is in business.

I am thinking of putting a new shut off valve further up the line and then moving the pressure regulator just distal to that so that the pressure regulator is proximal to the water softener lines.

As far as I can tell current state the pressure regulator does nothing since there is a tee to the water softener that comes off proximal to the pressure regulator valve.

Please let me know your thoughts.


r/askaplumber • • 12h ago

Helping my elderly father re-install a sink

1 Upvotes

In early August my father dismantled the bathroom in the basement of his house the day before he had a stroke. His intention was to replace corroded copper pipe leading to the sink in that bathroom with pex, so he'd taken the sink off of the wall, and taken the section of the wall down exposing the copper pipe. Then the stroke happened.

He's recovered to an extent, and he's been eager to get the basement repaired, but physically he's not able to do it himself. He hired a plumber to replace the copper with pex, so that's done, but he didn't want to spend the money to install the sink, so he's asked me to help him.

It seems like it's fairly straightforward. We have to connect the hot and cold supply tubes from the valves to the faucets, which I've done before. The issue I'm having now is the way he set up the p-trap and drain. He doesn't remember exactly how he set it up the first time, and I'm having trouble piecing together his original plan.

It looks like the bottom of the sink was connected to a p-trap, and then he'd connected a flexible extension tube (which we're replacing) from the bottom of the p-trap to the drain.

It looks like he connected two p-traps together at the bottom of the sink, and because of the direction of the threads on both the end of the p-trap and the drain I'm not sure exactly how to connect them. We purchased a Everbilt Form-N-Fit extension tube (1, 2, 3) from Home Depot which I thought would do the trick, but I can't line up the connections.

Can anyone help me make heads or tails of this setup, or advise on what I might need to finish connecting everything?

Here's a couple of pictures of the semi completed setup (1, 2)

NOTE: Based on what I've seen the last few months addressing a lot of my father's unfinished projects, he's the kind of person who would cut corners and half-ass everything just to save a few dollars. Now he's also in the early stages of dementia. So if the verdict is that he set this up completely wrong and I need to purchase a new p-trap or something to make sure it's done correctly, that's fine.

Apologies if I got some of this wrong, I'm very handy in general but I have limited plumbing experience. I changed the kitchen faucet at my apartment once, and I've snaked a drain a few times. Thanks in advance for anyone that can provide insight.


r/askaplumber • • 12h ago

Halp 😅 Shower diverter repair kit confirmation

Thumbnail
gallery
2 Upvotes

Hello! My partner and I have 2 shower diverters that need repair and it looks like the gasket has come out or worn in both. The showers work but it takes some finagling to get the seal to work.

The brand here Peerless but that itself doesn’t come up. It seems like Delta is the “umbrella” company?

Either way, what diverter repair kit would work for this style of shower? Thank you so much!


r/askaplumber • • 13h ago

What’s the best way to remove this faucet?

1 Upvotes

I have a vessel sink I inherited in a house I bought last year.

Faucet itself works fine but the supply hoses are corroded and I’m afraid they’ll start leaking— I’m currently dealing with major water damage in my house from another bathroom sink’s hoses that did just that.

Problem is the faucet the previous owner installed is a one-handle model that is held on by these tiny nuts. And because the sink is installed so tight against the wall, I can’t get a good purchase on it.

Will a basin wrench do the trick? I also tried to remove the vessel sink itself but it won’t budge.

photo of my sink

photo of my faucet


r/askaplumber • • 13h ago

Anyone installed an under-sink water filter?

1 Upvotes

Hi everyone,

Thinking of getting an under-sink drinking water filter. Anyone got one they’d recommend—or avoid?

Ideally, I’d like one that keeps natural minerals like calcium and magnesium. Has anyone compared these with reverse-osmosis filters that add minerals back afterwards?

Interested in whether yours improved the taste, filter replacement costs, and any installation or maintenance issues. Thanks!


r/askaplumber • • 13h ago

Hot water only hose bibb??

1 Upvotes

Moving into a new house. Southern California .The house is about 20 years old. There is a hose bibb on the side of the house that has hot water that is connected to the circulating hot water system. There is no other hose bib anywhere near it so I couldn't mix cold with it. Do you have any ideas why it would have been plumbed that way?


r/askaplumber • • 13h ago

Tankless water heater exhaust issue

Thumbnail
gallery
2 Upvotes

This is only 3 years old. What did they do wrong? Who should I call for the repair? TY