r/askaplumberUK • • 11h ago

Boiler Quote

2 Upvotes

Have just had a quote from British Gas for a new boiler and it’s come out at roughly £5k for a 2 bed 1 bathroom terraced house.

Our flue is on the roof accessed via the loft and the quote includes £1.3 for a scaffold tower plus 1.4k for the labour. The actual boiler is 1.2k.

Can anyone tell me if this sounds about right or is it insane? We only bought the place in April so haven’t built up the funds for this just yet but our current system is constantly breaking.


r/askaplumberUK • • 7h ago

F75 fault vaillant ecotec pro 28

Thumbnail reddit.com
1 Upvotes

r/askaplumberUK • • 9h ago

No stopcock outside of our property

1 Upvotes

For context, we had a small leak from our upstairs toilet (leak stopped once toilet was fully drained and mechanism to stop it filling up again was tied up).
We currently have a toilet we can’t use as a result.
We’ve had 3 plumbers out now who have all tried to turn off our stop cock in our house. (80s build but is completely sealed).

All of them have been outside and tried to turn off the stop cock on the road. Long story short, the one we thought was ours isn’t, but it does control next doors water supply. The one outside of neighbours house also controls hers.
There are no other visible holes anywhere else, and Anglian water are stumped too.
They believe that ours may have been accidentally covered over many years ago, and are planning to dig tomorrow to try and find where are pipes are.

Anyone come across this happening before, and if so what was the outcome?
Thank you


r/askaplumberUK • • 9h ago

No External Stop Cock outside our property

1 Upvotes

For context, we had a small leak from our upstairs toilet (leak stopped once toilet was fully drained and mechanism to stop it filling up again was tied up).
We currently have a toilet we can’t use as a result.
We’ve had 3 plumbers out now who have all tried to turn off our stop cock in our house. (80s build but is completely sealed).

All of them have been outside and tried to turn off the stop cock on the road. Long story short, the one we thought was ours isn’t, but it does control next doors water supply. The one outside of neighbours house also controls hers.
There are no other visible holes anywhere else, and Anglian water are stumped too.
They believe that ours may have been accidentally covered over many years ago, and are planning to dig tomorrow to try and find where are pipes are.

Anyone come across this happening before, and if so what was the outcome?
Thank you


r/askaplumberUK • • 9h ago

Losing my mind over boiler pressure dropping- Vaillant ecoTEC pro 24 combi boiler

Thumbnail reddit.com
1 Upvotes

I have a Vaillant ecoTEC pro 24 combi boiler, model VUW GB 246/5-3 A R4. The pressure drops every 10–14 days, and I have to repressurise it.

There are no visible leaks that I can find, including around the radiators, valves or radiator pipework. The pressure loss seems to happen after the heating has been used.

Two Gas Safe engineers have looked at it:

One thought it was probably the expansion vessel and the AAV (automatic air vent).

The other thought it was probably the expansion vessel. I paid £280 for it to be replaced, but the same pressure loss has happened again.

What would you recommend next: getting a Vaillant-experienced engineer to investigate the boiler, or arranging a trace-and-access service to look for a concealed micro-leak? Are there common causes of recurring pressure loss on this Vaillant model that I should ask the engineer to check?

I can add the cold and hot pressure readings if helpful.


r/askaplumberUK • • 10h ago

Persistent Sewage Odour and Recurring Drainage Blockages

Thumbnail
gallery
1 Upvotes

Hi, I have a persistent sewage smell in the bathroom, particularly around the toilet, and recurring blockages in the sinks.

The kitchen sink, washing machine and bathroom sink share a waste pipe. All have individual traps, and the main waste pipe connects directly to the side of the toilet soil pipe through an elbow.

The main limitation is the height available to increase the slope without having to remove wall tiles in the bathroom.

Help!


r/askaplumberUK • • 10h ago

Logic Combi C35 - please explain like I'm 5 years old

Thumbnail
gallery
0 Upvotes

Hi! I've tried to contact the helpline but it's out of working hours so I'm trying here.

I live in a flat with a logic combi c35 and struggling to figure out how to get central heating to properly work. Hot water works fine and the radiators work too, but only when using the specific "maximum CH rate" setting, which obviously isn't efficient and only gives any heat for 10 minutes. Other than that there's no central heating.

The room stat is set to 20 and changing it doesn't do much. I have no clue where to find the timer on the boiler because all this stuff is very new to me and google/manual isn't super clear or helpful for this situation. All I want is for the heating to come on by itself, especially as it's winter and this place gets pretty cold.

I'll be contacting the helpline again tomorrow but I figured I'd try here as well. If anyone could explain what could be going on in relatively simple terms, that'd be really appreciated because I have no idea what I'm doing. TIA!


r/askaplumberUK • • 14h ago

How do I turn off shower water?

Post image
2 Upvotes

r/askaplumberUK • • 13h ago

Broken trv?

Thumbnail
gallery
1 Upvotes

Fixing up my studio ready for winter, I've bled all 4 radiators but only 1 has water flow and gets warm. I've pulled this trv but looking at pics online it looks like it's missing a pin in the middle. Is this one broken or is there a valve by the boiler I need to flip for it to come back?


r/askaplumberUK • • 14h ago

Moving radiator to another wall in tenement flat

Thumbnail reddit.com
1 Upvotes

r/askaplumberUK • • 15h ago

Boiler condensate pump issues

Thumbnail gallery
1 Upvotes

r/askaplumberUK • • 1d ago

Water hammer after new boiler installed.

1 Upvotes

Hi all, I had a new boiler installed last week Worcester Bosch 4000 30KW.

Ever since it was installed on Friday I’ve noticed a water hammer any time the washer is one regularly towards the start and end of every cycle. As well as this I get a clang any time I open a tap either hot or cold both upstairs and downstairs. The quicker I open it the louder the hammer.

I never heard this noise once from my previous boiler. Vaillant 25+ years old.

I had my boiler installed by Boxt, the installer did leave his number and said to drop him a message if any issue within first 4 week so I will probably drop him a text tomorow he was a really miserable guy though so might just do direct to Boxt.

One last point he did install and Shock Arrester as part of the install which I can see and he showed me during instal.

Can this be fixed easily will the installer just say it’s unrelated, or perhaps I need new pipework could really do without any additional work and cost.

But the noise Is driving me mad and I also fear
A leak, especially with the noise when the washer is on. Opening taps slowly does prevent it.

Any help much appreciated.


r/askaplumberUK • • 1d ago

Radiator bleed valve

Thumbnail gallery
1 Upvotes

r/askaplumberUK • • 1d ago

Working in domestic hot water and cold water

Thumbnail reddit.com
2 Upvotes

Can I keep my central heating running from my combo boiler while the domestic hot water is drained and mains water off at the stop cock


r/askaplumberUK • • 1d ago

Wren Ceto mix tap bot working

Thumbnail gallery
1 Upvotes

r/askaplumberUK • • 1d ago

Boilers - Help Me!

Thumbnail reddit.com
1 Upvotes

r/askaplumberUK • • 1d ago

Unsure of rip-off

1 Upvotes

Hi all,

From the UK. I have a 1960s build house. We just bought it and the plumbing for drainage to the manhole is clay. We had issues with flushing etc. we had a drainage specialist out to unblock and use a camera to see what's going on.

  1. From the downstairs toilet, it goes into a 90 bend which has sunk about 7mm. Then a meter stretch, then into a 120 bent and then another meter until it's hit the manhole. Some of the segments have small cracks or sunk by 1mm. He is saying to do the job he would have to dig 2 holes. One for the 90 bend to put concrete underneath to lift it. And another so that he can then line both segments of pipe. All this for £1850+VAT. If we excavate ourselves, it's £1550+VAT.
  2. from the upstairs toilet, it comes into a 90 and then 1 meter of pipe. 90 has dropped about 4mm. To line all that (he believes that it should be a problem and would stop any more sinking for the 90) is £200+VAT as would not require any digging.

He has said that if we do that with him, he will drop the £250+VAT for work don't tonight. I can't tell if we are being ripped off or not. Please give second opinions. Need to give a response by mid day tomorrow. Thank you


r/askaplumberUK • • 2d ago

Combi mains flow rate

1 Upvotes

I am considering installing a combo boiler to replace a very old tank and shower pump system in a small 2 bedroom/1 shower room top floor flat. At the moment I am heating ups water tank twice a day and it seems like a waste for the small amount I use.
I have had 2 different plumbers round. Both ran the kitchen tap and said it’s is water flow would be fine for a combo boiler.
However, I have measured flow rate myself and it is only 6.7 L/min which I’ve read is too low for a combo to work properly.
I don’t want to go ahead with this and find the shower pressure is terrible. And I don’t interest why the plumbers are telling me it will be fine.
There is an options for a mains water pump I suppose but I’m concerned that would be very noisy.
What should I do?


r/askaplumberUK • • 2d ago

Terrible customer service

Thumbnail reddit.com
1 Upvotes

r/askaplumberUK • • 2d ago

Heating upgrade advice: modern gas boiler or air source heat pump?

1 Upvotes

Hi everyone. I’d appreciate real-world advice from people who’ve made this decision, especially anyone with a Victorian terrace in London.

We’re weighing up replacing our existing boiler with a modern gas system boiler, such as a Viessmann Vitodens, or switching to an air source heat pump (ASHP).

Our home and current system

- 1890s, three-storey Victorian mid-terrace in North East London; family of five.

- Current boiler: 2013 Potterton Titanium 33 kW combi, adapted to heat a 250 L Tempest unvented hot water cylinder.

- Around 40 m² of wet underfloor heating downstairs, with radiators on the upper two floors.

- 8 kWp solar PV array and a 16.1 kWh home battery.

Our gas use was around 10,000 kWh/year before we switched the cylinder to immersion heating. Since then, it appears closer to 7,000–8,000 kWh/year, although that isn’t a weather-adjusted comparison. Hot water is now heated electrically, so our current gas use is mainly for space heating.

Heat pump option

We’ve had a room-by-room heat-loss survey and are considering a proposal for a 10 kW Viessmann 200-A heat pump. The quoted cost is around £7,000 after the £7,500 Boiler Upgrade Scheme grant, with no radiator changes under the Zero Disrupt option. Other installers have discussed different models and possible emitter changes.

One thing we’re trying to understand is the difference between our historical gas use and the heat pump’s projected annual electricity use, including hot water. We’d also like to know how realistic the predicted efficiency and running costs are in practice.

Gas boiler option

Our existing boiler is 13 years old, and we’re considering whether a modern condensing system boiler would be a sensible, lower-cost replacement. I haven’t established how much energy or money a new boiler would save in our particular setup, so I’d be interested in experiences from people who’ve replaced a similar boiler and cylinder system.

Questions

- If you switched from gas to a heat pump in a similar Victorian terrace, what were your actual electricity use, SCOP and running costs compared with the installer’s estimates?

- How have you found the outdoor unit’s noise and appearance in a typical London mid-terrace garden?

- With our relatively modest gas use, existing underfloor heating, solar and battery, would you choose the heat pump or replace the boiler? What figures drove your decision?

Thanks for any experiences or advice!


r/askaplumberUK • • 2d ago

ESI 2-port valve

Post image
1 Upvotes

Have an ESI ES ZV 222L 2-port zone valve that leaked from the spindle through the head unit. Took the cover off the head unit to make sure the electrics/clockwork looked OK and a wire about 5cm/2in with a loop and a bent tail just fell out (see photo).

Any ideas on where it fits back in? A picture of a similar ESI valve with it in place would be worth a 1000 words...


r/askaplumberUK • • 2d ago

Pressure

Thumbnail
gallery
1 Upvotes

Can anybody help me figure how to repressurise my boiler? I bled the radiator and it completely drained the boiler


r/askaplumberUK • • 2d ago

New Bathroom Advice

Thumbnail gallery
1 Upvotes

See post above. Any advice or comments are appreciated.


r/askaplumberUK • • 3d ago

Broken basin

Post image
2 Upvotes

r/askaplumberUK • • 3d ago

This shower won’t run cold

Thumbnail gallery
2 Upvotes

Posting here as well in hopes someone can help me get a non scalding shower.