r/askaplumberUK • • 19h ago

Working in domestic hot water and cold water

Thumbnail reddit.com
2 Upvotes

Can I keep my central heating running from my combo boiler while the domestic hot water is drained and mains water off at the stop cock


r/askaplumberUK • • 6h ago

Water hammer after new boiler installed.

1 Upvotes

Hi all, I had a new boiler installed last week Worcester Bosch 4000 30KW.

Ever since it was installed on Friday I’ve noticed a water hammer any time the washer is one regularly towards the start and end of every cycle. As well as this I get a clang any time I open a tap either hot or cold both upstairs and downstairs. The quicker I open it the louder the hammer.

I never heard this noise once from my previous boiler. Vaillant 25+ years old.

I had my boiler installed by Boxt, the installer did leave his number and said to drop him a message if any issue within first 4 week so I will probably drop him a text tomorow he was a really miserable guy though so might just do direct to Boxt.

One last point he did install and Shock Arrester as part of the install which I can see and he showed me during instal.

Can this be fixed easily will the installer just say it’s unrelated, or perhaps I need new pipework could really do without any additional work and cost.

But the noise Is driving me mad and I also fear
A leak, especially with the noise when the washer is on. Opening taps slowly does prevent it.

Any help much appreciated.


r/askaplumberUK • • 11h ago

Radiator bleed valve

Thumbnail gallery
1 Upvotes

r/askaplumberUK • • 15h ago

Wren Ceto mix tap bot working

Thumbnail gallery
1 Upvotes

r/askaplumberUK • • 17h ago

Boilers - Help Me!

Thumbnail reddit.com
1 Upvotes

r/askaplumberUK • • 20h ago

Unsure of rip-off

1 Upvotes

Hi all,

From the UK. I have a 1960s build house. We just bought it and the plumbing for drainage to the manhole is clay. We had issues with flushing etc. we had a drainage specialist out to unblock and use a camera to see what's going on.

  1. From the downstairs toilet, it goes into a 90 bend which has sunk about 7mm. Then a meter stretch, then into a 120 bent and then another meter until it's hit the manhole. Some of the segments have small cracks or sunk by 1mm. He is saying to do the job he would have to dig 2 holes. One for the 90 bend to put concrete underneath to lift it. And another so that he can then line both segments of pipe. All this for £1850+VAT. If we excavate ourselves, it's £1550+VAT.
  2. from the upstairs toilet, it comes into a 90 and then 1 meter of pipe. 90 has dropped about 4mm. To line all that (he believes that it should be a problem and would stop any more sinking for the 90) is £200+VAT as would not require any digging.

He has said that if we do that with him, he will drop the £250+VAT for work don't tonight. I can't tell if we are being ripped off or not. Please give second opinions. Need to give a response by mid day tomorrow. Thank you