I have an Ecodan 11.2 kW in a house with a mix of underfloor heating and radiators. I never got the FTC's weather curve right. Too high and the COP suffers; too low and some rooms never warm up. Every tweak meant waiting days to see the effect.
So I built a controller that sets the flow temperature itself and learns from the result. It runs in Docker alongside Home Assistant, reads the temperature in every room, and adjusts the curve depending on whether rooms ended up too warm or too cold.
First sub-zero night this month: outside went from 3 °C to −2 °C, the flow rose gradually from 38 °C to 48 °C, and the house stayed at 20.2–20.5 °C. It had never seen frost before; by morning it had learned its own frost curve from that one night. The curve is now about 34 °C flow at 10 °C outside, 37 °C at 5 °C and 41 °C at 0 °C.
What's under the hood:
- Two curves, split at about 2 °C, because defrost cycles eat into heating time. It blends between them so there's no jump. Until it has frost data, the frost curve follows the normal one.
- Being too cold counts double compared with being too warm, so it never saves money by leaving you cold.
- Rooms are weighted. A cold living room matters more than a cold spare room, and every room still has a minimum it must not drop below.
- Solar gain is worked out properly. It learns what your panels produce on a clear day at each time of day, so it can tell direct sun from bright cloud. It knows which side of the house the sun is on, so only the rooms it's actually shining on get credited.
- Tariff aware (Octopus, or any supplier whose prices are in HA). It stores heat in the underfloor screed during cheap hours and coasts through the peak, but only while every room stays comfortable.
- It never learns from bad data. Sensor dropouts, restarts and mode changes are held through and left out of the learning. If the outdoor sensor drops out, it switches to a backup source. If everything fails, it doesn't change anything rather than guessing.
- Every write is checked by reading the setpoint back from the unit.
You need the Ecodan already in HA with a flow temperature it can write to, plus temperature sensors in your rooms. Observe mode runs for a week showing what it would set, without touching anything.
It isn't public yet. My own version also runs hot water, summer cooling, Solcast PV forecasts and battery load-shifting, but those are too tailored to my house to release yet. Yes, I built it with a lot of AI help, and it's been running my house for two winters.
Would anyone use it, to release it I'd need to do some work to make it transferable and easy to setup for another person so before I go to the effort thought I'd ask!? Some screenshots attached