I work on special door packages, and acoustic doors are where I see buyers spend the most money for the least result. Not because the doors are bad, but because the number on the datasheet gets treated as a guarantee.
Here is the checklist I run through before quoting anything, in the order that actually matters.
Mistake 1: buying the Rw value instead of the assembly
What happens: someone asks for a "Rw 45 door" and the supplier quotes a leaf. What arrives performs well in the chamber. The wall around it, the frame infill and the threshold do not.
Better: specify the opening as one scope — leaf, frame, perimeter sealing, threshold and the wall build-up that the door has to match.
Mistake 2: leaving the door bottom undefined
This is the one that kills most projects. A leaf with good mass and a 12 mm gap under it is a leaf with a hole in it. Decide between an automatic drop seal and a fixed sweep before you order, and state the maximum clearance at handover.
Mistake 3: never measuring the noise you are actually fighting
Speech and mid-frequency noise respond well to sealing and mass. Low-frequency plant noise mostly needs mass and decoupling, and no amount of felt will save an undersized leaf. If you do not know which one you have, you cannot spec rationally.
Mistake 4: over-thick seals the closer cannot overcome
I have seen doors that technically sealed perfectly and still failed, because staff could not close them without slamming. Compression has to be matched to the closing device, and that is a commissioning step, not a catalogue step.
Mistake 5: accepting the lab certificate as the end of the job
Lab conditions are controlled. Your site is not. Ask for an on-site re-check clause and agree what happens if the number is not met — before installation, not after.
Disclosure, since it is relevant: I work with Guangdong Longdian Security Products, so I see this from the fabrication side. No links, no pitch — the same checklist applies whoever you buy from.
Curious how others handle it: do you write an on-site re-test into the contract, or accept the lab certificate and hope the installer gets the perimeter right?