r/buildingscience • u/dwl715 • 6d ago
r/buildingscience • u/EmergencyEfficient21 • 6d ago
Has anyone taken the BPI energy auditor exam recently?
r/buildingscience • u/TheKingofBoggle • 6d ago
wood floor above slab
Im doing a wood floor on top of a slab. Construction documents include a build up of a 3/4" subfloor directly on top of slab with 1/4" cork underlayment between 3/4" finish floor and subfloor. theres no room for any sleeper framing as this 1-3/4" build up due to door heights / clearances. Slab was poured in July, is 4" thick with 12" thickened haunches in areas, and includes a 15mil vapor barrier below. Zone 6a
Not sure the best way to put the subfloor down. I think using glue as opposed to mechanical fastners may be best option?
I know this isnt exactly a building science related question, but ive been hesitant to start because of potential moisture in the slab not having anywhere to escape? Project sequencing is looming though. Looking for any advice! thanks!
r/buildingscience • u/Consistent-Year-9238 • 7d ago
Mold beneath sleeper floor system
Mold in floor
So my customer had someone build addition over concrete patio 2-3 years ago. Photo above is during construction. Guy did spf sleeper floor system and 3/4” t&g no vapor barrier. Homeowner has tested for mold. Aspergillosis and penicillin are of charts beneath floor. They want to rip this out, mitigate and put back together. My thought is rip sleepers out. Seal slab and lvp on top and learn to live with 2”heights difference. Main concern tho is preventing any further organic growth. Anybody have some insight or SOP that applies here?
r/buildingscience • u/floor-install4u • 7d ago
Question How are radiant heated film floor heat systems in the market?
I’ve been very confused lately. I’m an installer and I do tile floors and different floating floors. I’ve gone to a few local trade shows and the past two NWFA shows to understand what I can offer for radiant heat on the floors. I know there’s a lot of perspectives on floor heat in general but what I’m really confused about is how major retailers are still selling heated film systems for heated floors and they claim ETL certified. Everyone is telling me at the these shows that they are not UL approved anymore and most inspectors will ask you to remove it since it doesn’t have a built in ground protection. Are people just taking the risk and not following code?
I’ve been suggested other solutions but I feel like I’m missing something since it still on the market. Would love some guidance and clarity.
r/buildingscience • u/Willman3755 • 8d ago
Question Euro-style flange-less windows with exterior insulation, installed "outie"

Hi all, I will be building a relatively modest but high performance "pretty good house" myself in the next year in northern VT (zone 6A).
The plan right now is 2x6 construction w/ celluose, CDX + VP100 WRB, plus 2.5" RockWool ComfortBoard continuous exterior insulation, 1x3 furring, and LP SmartSide 76 lap siding.
We'd like "outie" windows for deep interior sills and a more traditional look from outside, but also wish to do euro tilt and turn turn triple glazed. This presents window detailing challenges.
At least one US supplier of euro windows (Broga) includes an extra profile on the bottom that I believe is specifically to support external sills, but it is hidden in an install manual with no other mentions I can find. Is this type of profile a standard addition to these windows in Europe when a sill pan is needed like this?? I have an inquiry out to Broga on this as well to confirm if this bottom profile can be used in the manner I'm hoping.
Looking for a sanity check on this proposed window detail and if anyone else has solved this issue before. Personally, I'm into very new territory designing these kinds of details myself instead of just finding a suitable one online somewhere with discussion. Not drawn here, but jambs would be the same as the head but without the Z-flashing, with the siding caulked directly to trim instead. Also not drawing - exterior trim frames would likely be shop-made with pocket screws on the back, then nailed directly to the buck.
Thanks for any insights here.
r/buildingscience • u/No_Awareness9472 • 8d ago
1980s Florida home — Wood framing against concrete block walls is wicking moisture (13–17%). Mold found. How do I permanently fix this?
reddit.comI recently purchased a home built in 1983 in Tampa, Florida, and I’m trying to figure out the correct way to address moisture along the bottom of my exterior concrete walls without spending thousands on the wrong solution.
The house has thick concrete block exterior walls with wood framing installed against them, insulation, and drywall.
During some remodeling, we discovered moisture and mold behind the baseboards along the exterior walls. We had mold testing performed, which identified Stachybotrys in some of the affected areas.
Here’s what we’re seeing:
● The tile floors themselves are testing dry.
● The wood framing/baseboards against the exterior concrete walls are measuring approximately 13–17% moisture content, with some areas as low as 9.6%.
● The higher readings tend to be near windows and along the bottom of the walls.
● We found some dark mold growth around nails and along the bottom of the wood.
● The concrete walls themselves don’t appear visibly wet.
● Indoor humidity is generally around 45–55%.
● Some of the mold appears to be historical, but I’m trying to determine whether moisture is still entering.
My theory is that the wood is absorbing moisture directly from the concrete block walls, or that humid air is condensing inside the wall cavities.
This is Florida, so the outdoor humidity is obviously high much of the year. I’m concerned that even if I replace all the affected wood and drywall, the same problem will happen again unless the wall assembly is corrected.
I’ve had contractors offer to waterproof/seal the exterior foundation and lower concrete walls, but I’m not convinced that’s the actual source of the moisture. I don’t want to spend $10,000–$16,000 on foundation waterproofing if the problem is really condensation or moisture wicking from the concrete.
My questions for anyone experienced with Florida concrete block construction:
- Is it normal for wood framing against concrete block walls to measure 13–17% moisture in Florida?
- Could this be capillary moisture transfer from the concrete into the wood rather than an actual foundation leak?
- How do you properly separate wood framing from concrete block walls to prevent moisture wicking?
- Should there be a vapor barrier, rigid foam insulation, sill gasket, or some other material between the concrete and wood?
- How do you prevent condensation inside these wall cavities when the AC is running and it’s hot and humid outside?
- Would exterior waterproofing help, or could it potentially trap moisture inside the walls?
- What’s the proper way to rebuild these walls so they can dry and won’t develop mold again?
I’m looking for a long-term building-science solution, not just spraying mold killer, painting over the concrete, or replacing wood only to have the problem return.
Has anyone dealt with this in an older Florida concrete block home? What actually fixed it?
I’d especially appreciate input from Florida contractors, building-envelope specialists, or anyone familiar with moisture management in hot, humid climates.
Thanks in advance!
r/buildingscience • u/denver_based • 8d ago
Advice on crawlspace
I live in a 1952 home in Minnesota. I want to improve my crawlspace situation for better indoor air quality and thermal comfort. The crawlspace is below my kitchen area, and connects to my full basement in the utility room (picture of that connected area above). It has an HVAC supply and return duct in it.
Currently my crawlspace has a radon vapor barrier (15mil) taped to rigid foam board around. There is also fiberglass insulation on the subfloor.
This is how I am thinking about the steps, but would love advice.
- Remove fiberglass insulation from subfloor.
- Spray foam the rim joists around the crawlspace.
- Insulate the HVAC ducts
Do I need to put in a dehumifier in the space? Should I try and close off the access point more with a board in this area? Do I need to spray foam any of the subfloor?
Thanks for advice and happy to provide more information if helpful.
r/buildingscience • u/ChemistAsleep395 • 8d ago
Smart vapor barrier for 1890s renovation
I’m trying to decide which smart vapor barrier is better for my 1890s farmhouse renovation. Foundation/ new floor system has been repaired and replaced. I’m getting closer to insulating (northern Michigan winter coming soon). Going back and forth between ProClima Intello plus vs Certainteed Membrain. Exterior of the house is original lap siding over the studs which is covered by vinyl siding ( I’m hoping when the vinyl was added there is a house wrap but I won’t be certain until I replace the windows. I’ll add the house wrap everywhere I am able if it isn’t there when the vinyl comes down for the windows.
I am leaning towards the Intello plus based on my research, only part that I am nervous about is sealing up the wall cavity too good as the house was never originally like this and there has been absolutely no rot. Current plan is to insulate with rockwool, then add smart barrier over the studs, then 1/2 inch osb to prevent further racking etc. drywall after.
Any thoughts? I haven’t reached out to either manufacturer to check thier opinions on osb going over the top and how that changes vapor permeance
r/buildingscience • u/Hey_there343 • 8d ago
Keene Driwall Rainscreen Behind Stone Veneer
Does Keene onscreen count as a secondary WRB over Zip system sheathing? I’m seeing it’s not but builder insists it will be fine.
r/buildingscience • u/iiililiililiilliilli • 8d ago
Question Open cell spray foam for Michigan rim joist - does this need remediation?
I had open cell spray foam sprayed into my rim joist in a 1995 era Michigan home with an unfinished basement about four years ago. When I've dug through the foam to run wires the wood behind it seems fine. But I understand that open cell in a rim joist can promote moisture issues. Do I need to remediate this, or is it probably ok to leave as is?
r/buildingscience • u/sierraxxxxx • 9d ago
Question Roof vents vs soffit - cold weather climate
Hi everyone
We live in a small, old house in Calgary Alberta and need to up our insulation. Soffits are not vented and would require a lot of work / $ to get them to a point that would support the extra attic insulation we also require. Roofing fella suggested we opt for several roof (intake) vents instead. It seems a popular option for new builds, but I’m also wondering what the chances of them getting blocked by snow in the winter months.
Any experience you can share? Thanks.
r/buildingscience • u/MovieFirst1234 • 9d ago
Climate Zone 5a without furring
Hello all,
I am building a home in climate zone 5a. From my research, the requirement on my plans (r-20 + 5ci) is not a great idea because of my cavity to continuous insulation ratio. I am going to use r-21 batts but am unsure of what to use on the exterior. It seems like I should be using something R-7 or higher but this would be a minimum 1.5" thick and require me to install furring strips in order to install LP Smartsiding (installs over 1" foam maximum). Can someone help me determine other options with 2x6 framing, r-21 insulation, and no furring strips? Would these options be acceptable?
Option 1: Use Zip-R9 and LP smartside attached with tetragrip nails
Option 2: Use R-21 insulation and r-5 ci but with a smart vapor retarder between drywall and studs
r/buildingscience • u/Nathan-Ikonografik • 8d ago
What does breathable actually mean in the context of a building?
What does breathable actually mean in the context of a building? Does the building breathe like I do with air coming into my lungs & back out again as carbon dioxide?
No, not exactly.
It means that the building materials can transmit moisture.
Breathable building materials are permeable enough so that any moisture from humid air & moisture from surface wetting can be absorbed & can then easily evaporate during dryer warm periods.
A lot of natural, traditional building materials have inherent properties that allow moisture vapour to pass through them, they are vapour permeable. These materials can also absorb & retain moisture in vapour form [like moist damp air in the background or from a bathroom], this means they are also moisture buffering [the scientific word for this is ‘hygroscopic’].
Another way to describe these 'breathable' building materials is that they are ‘vapour open’ or ‘vapour permeable’.
This is very different from some modern, synthetic building materials that are made from fossil fuels & plastic and are heavily processed. These are the opposite & therefore classified ‘vapour closed’ or ‘non-vapour permeable’. They don’t ‘breathe’.
Here’s a couple of cross section sketches that show how this works in practice.
Sketch 1 illustrates a breathable vapour OPEN construction.
Breathable vapour open buildings mean that background water vapour is intended to enter the constructional build up, it’s not intended to stop it entering. Over the colder, damper winter months, with higher internal humidity, a certain amount of water vapour moisture can enter the build-up & is temporarily stored in the insulation. Then, over the warmer, summer months, when the internal humidity drops, the stored water vapour moisture can evaporate harmlessly into the room.

Sketch 2 illustrates a non-breathable vapour CLOSED construction.
Sealed vapour closed buildings can work but as they rely on internal vapour control membranes that are not vapour permeable, they need extremely good site workmanship [should that be ‘workpersonship’?] to ensure the insulation is fitted tightly without edge gaps and the internal membranes are installed fully sealed without any gaps or holes. In reality it’s likely there will be gaps, as I understand it is impossible to ever build a 100% fully sealed construction.
Nature knows best, who’d have thought it?

r/buildingscience • u/23458357234839742389 • 9d ago
Do any of you building science enthusiasts garden, and have a need to overwinter a few plants?
I’ve run out of time on the central coast of NJ, and I need to get my two small citrus trees into their winter home.
Not only have I lost the battle against fungus gnats in the soil the past few years, but I never really had a place inside to keep these potted plants to begin with. No basement, no sunroom, so extra space at home anywhere :(
Unfortunately, the lemon and lime pair were purchased without considering where the plants would live during the winter. Even though I was not happy to see them arrive after they were purchased, I do like them and want to keep them alive.
I need some kind of temporary solution to overwinter these plants for 1-3 cold seasons. I have access to more than enough extra,and scrap, zip sheathing, rockwool batt insulation, and everything else to build a nice little box. All the fasteners, sealant, and tape you can dream of. I can purchase anything else needed, but I wont need much. I even have a bonus bucket of Redgard, extra fiber cement and aluminum siding, and exterior paint if I want it to look nice.
What I was thinking was a mini “shed/greenhouse”. Its joists will rest on those plastic feet people build sheds on. Insulated floor(?), insulated walls. Gable, shed, or reinforced flat roof made of plexiglass, that’s also hinged for watering the plants. Extension cord for a very small space heater with great thermostat sensor and controls. Presumably it would need some kind of waterproofing on the subfloor and a small amount of intake/exhaust, accounting for outside air temp hopefully. It’s only meant to last for 1-3 years, so upmost build quality isn’t a priority. Poor ventilation won’t bother me if I can’t make it work easily enough. Would prefer to build it well, and tight enough to keep out pests, and also not have the space heater running 24/7 trying to maintain temp.
Or is there some kind of bullshit greenhouse thing I should just buy from Amazon that will be good enough to keep the warmth in? And do you know which one would work?
Don’t need to plants to produce during the winter. Minimum need is dormancy.
Interested to hear of any of you also garden and have the same problem.
r/buildingscience • u/Adventurous_Rope_921 • 10d ago
Tips for insulating rim joist? Cold climate.
galleryr/buildingscience • u/pudungi76 • 10d ago
Patio Lights with Living Space Above
I have outdoor patio with enclosed living space above. The patio ceiling is zip sheathed and taped and air sealed. How do I add lighting to the ceiling without compromising air tightness? The only option I can think of is to have wafer led lights -do they have drivers? Or is there a way to install 3" deep recessed LED COB lights? The fixtures are airtight but I am worried the installation will create small gaps at each installation especially with a 3" hole in zip.
r/buildingscience • u/Dauntzey • 10d ago
*Seeking insulation advice for post-war weatherboard house (Sydney climate, no roof cavity)*
galleryr/buildingscience • u/Technophile63 • 10d ago
Question Insulated False Ceiling in Shed?
galleryHow can I do this without condensation? Is it OK to attach ten foot rafters to the sides of concrete block walls (I think it's 4" blocks, 4" foam, 2" air, 4" blocks)?
r/buildingscience • u/skalatitude420 • 10d ago
Cellular Shades, inside or outside mount for optimal insulation?
2 of the big online shops for window treatments say the exact opposite of one another regarding which is preferable if insulation is the top priority. Blinds.com says inside. Simply Blinds says outside. Does it much matter? If so, which is actually preferable?