r/Generator • • Jun 02 '24

Generator Tips/FAQs: Please read before posting

48 Upvotes

The following tips/FAQs address commonly-asked questions in this sub. Please take a look at them before posting a question.

CO Safety

Generators produce carbon monoxide when running. Carbon monoxide is a deadly, invisible, and odorless gas. Carbon monoxide from generators kills hundreds of people each year. Do not ever operate a generator in a house, garage, or any connected structure, even if the windows and doors are open.

The U.S. Centers for Disease Control recommend only ever using generators outside, more than 20 feet away from your home, doors, and windows.

Fuel

Each type of generator fuel has its pros and cons.

Connecting a generator to your loads (appliances)

Generators can be connected to your loads with extension cords or by connecting the generator to your house's electrical system using a transfer switch or interlock device.

Read more about these methods on our wiki.

Generator sizing

Our wiki contains tips on picking the right size of generator for your needs.

Inverter vs. conventional generators

Inverter generators generally consume less fuel and produce "cleaner" power than conventional generators. More information on this is available on our wiki.


r/Generator • • 3h ago

Need a generator. Start-up wattage vs the wattage of the device?

2 Upvotes

Might be overthinking it but I thought maybe some night owls (it’s 1am for me) could help.

I have a lease but I can’t break it.

I want to end utilities until I find a subletter, but I also wanted to get a generator to have my lights + heater on to at least work out in privacy there and make good use of the situation I’m in. My pockets hurt.

Lights are 47-watts, heater is 1500watts.

I read I have to take into account the startup power it needs, wattage-wise.

Do I go with a 3500 watt generator ?or 4000? Or would 2000w be enough ?

My pockets hurt but the lighting bill is going to hurt more. I’d rather buy this generator and have it in general/emergency, and use it for this in the meantime. Please don’t judge me, I have no family and im young trying to make good choices but it’s really hard .

ETA: earlier this month, one bill was $500+ for lighting alone.

Even if im never/barely home, it’ll be minimum $50 or $100 / mo I’m assuming, just to deliver the service. It was high even when I was with roommates. I’m in NYC (did not ask to be here, actively trying to save up, leave).

So I’m thinking, save the money, end utilities, and buy a generator for emergencies/to run heat and lighting (we had hurricane sandy once and I was here for it, lives were lost, no power for 2+ weeks, and with the way the world is right now, we’re going to see another catastrophe i bet).

But I see the redundancy of using gas power to burn heat.

I just need advice I guess? I’ll post this elsewhere as well.


r/Generator • • 11h ago

Is this a good generator to power gas furnace, gas hot water heater, fridge, freezer, 3 playstations and 3 tvs? Price is in Canadian dollars.

Post image
7 Upvotes

r/Generator • • 8h ago

Neutral Wires in a Transfer Switch

2 Upvotes

I want to change my 15 amp breaker to a 20 amp breaker. I will change the hot wire gauge coming from that breaker. Do I need to change the neutral wire? The transfer switch just has the wires fed into a neutral bus bar.

Generac Transfer Switch Model 6852


r/Generator • • 14h ago

Any objections to the Genmax 13500iETC?

Post image
6 Upvotes

I've made a final decision on a genset but wanted to get you guys opinions on it before I pull the trigger. It checks all of my boxes on paper. Any objections?

My only concern I can think of is that it being a "C" model designation, does it carry any additional emissions equipment or anything that could malfunction due to it being a CARB model "California legal"?

Editing to add price is $2341 during black Friday.


r/Generator • • 19h ago

Predator EFI

Post image
16 Upvotes

Has anyone tested the Predator EFI inverters? Any chance they're a solid competitor to the Honda?


r/Generator • • 14h ago

Westinghouse's NG hose manual shows a bare shutoff valve with no quick-disconnect. Is anyone actually setting up portable generators this way? And why does code allow it?

Post image
6 Upvotes

Questions:

  1. Is anyone here running a portable generator on NG with just a valve, like in the drawing? How do you keep it safe?
  2. Why do you think the code allows a just a non-locking valve?

I'm hooking a Westinghouse generator to natural gas and have a concern about what the company shows in this image. The Westinghouse 1/2" hose's user guide has a this drawing. They seem to be recommending an outside connection where the hose threads straight onto a shutoff valve on the house supply line. The shutoff valve has a non-locking handle, and nothing more.

There's no quick-disconnect in the picture.

Since these are for portable generators, you'd think the hose is disconnected when not in use. Indeed, that hose end uses a flared connection and the instructions say, "See Figure 2. Hand-thread the natural gas hose (1) to the natural gas supply line (2)."

That bothers me. Nothing in it shuts the gas automatically. If the valve is open when the hose is off, gas flows from an open outlet. A kid could open the handle or someone could bump it open, especially if the ball valve has a bigger 1/4 turn handle.

As I read NFPA 54, the outdoor hose rule allows an appliance shutoff valve or a listed quick-disconnect or a gas convenience outlet where the hose attaches.

So a plain valve is enough for code... but is it smart? For examples of this connection when in use, see this video or this one or this one.


r/Generator • • 5h ago

Need general ideas on picking and choosing what type of generators I would want in my house

1 Upvotes

I am pretty sure this questions has been asked here million of times. But folks please help me as it is very difficult for me to decode all the voltage and amperes and watt hour stuff.

All my stuffs in my house is electric, that include cooking on electric stove top, refrigerator, oven and the whole heating. I have a heat pump that is electric (no natural gas or propane tank or oil usage) The power outage in my area is rare but it does happen during snow storms. Last time it happened I was without heat for good 6-8 hours.

I am thinking of getting a generator that can be fueled by gas or propane. I am confused as to what power or capacity I should get. And also questioning whether these generators are able to power the whole home including my heating. i was looking at whole home generator and they cost a fortune $$$ I am not looking to spend that much on the generator for now. Can you all advise on what I should get and how I should go about doing it.

As always I am in debt to reddit community. Happy holidays folks.


r/Generator • • 9h ago

Multiple 14-30R receptacles?

0 Upvotes

Right now I want to install an outside 14-30 inlet receptacle and a panel interlock for my generator.

In the future, I am going to want the receptacle inside near the panel, because I hope to install a battery backup capability. I can envision a use case where direct generator power might still be a contingency.

Can I install one 14-50 inlet outside and one inside now, and wire them together? I would only ever use one or the other.


r/Generator • • 16h ago

UPDATE: DuroMax XP11000iHT vs. Champion 201423 Inverter – Minnesota Winter Backup

4 Upvotes

Thanks to everyone who contributed to my original post. After doing considerably more research, I've decided to prioritize an inverter generator to provide cleaner power for my two high-efficiency natural gas furnaces and other sensitive electronics.

I've narrowed my search down to two tri-fuel inverter generators:

  • Champion 201423: 7,290 running watts / 11,000 starting watts on NG, <3% THD, 64 dBA, 3-year warranty.
  • DuroMax XP11000iHT: 7,700 running watts / 9,500 starting watts on NG, <3% THD, 61 dBA, AGM battery, 5-year warranty.

The DuroMax offers 410 additional running watts (5.6% more capacity), while the Champion offers 1,500 additional starting watts on natural gas.

My neighbor purchased the Champion earlier this year for $2,100, although he hasn't operated it in extreme cold yet. I'm currently leaning toward the DuroMax, which I can purchase for approximately $2,667, despite limited availability.

My home and backup power needs:

I live in Minnesota in a 4,190-square-foot home with 200-amp electrical service. I'm preparing for potentially extended winter outages of up to 14 days, with temperatures potentially reaching -20°F.

My estimated essential running loads are:

  • Amana 97% modulating, variable-speed natural gas furnace: 700–1,200W
  • Daikin 96% single-stage natural gas furnace: 400–800W
  • Refrigerator/freezer: 150–350W
  • Natural gas power-vent water heater: 50–150W
  • Essential lighting: 100–250W
  • Modem/router: 20–50W
  • Computers, phones and other small electronics: 100–250W

Estimated essential running load: 1,520–3,050W, pending verification by my electrician.

I'd also like the flexibility to selectively operate a second refrigerator/freezer, microwave, washing machine, dishwasher, rechargeable power station and potentially one electric cooktop burner. I'm comfortable managing these loads and have a separate propane camping stove and grill.

I'll primarily run the generator on natural gas and store it in an unheated, insulated garage, moving it at least 20 feet away from the house for operation. Electrical and natural gas connections will be professionally installed.

I'd appreciate thoughts on the following:

  • Cold-weather reliability: Has anyone started or operated either model in subzero temperatures? Does the DuroMax's AGM battery offer a meaningful advantage?
  • Clean power: Has anyone measured THD, voltage stability or power quality under varying loads with either model?
  • Power capacity: Given my estimated loads, would you prioritize the DuroMax's additional running watts or the Champion's additional starting watts?
  • Build quality and reliability: Is one manufacturer or specific model better regarded for extended emergency use?
  • Service and warranty: How have your experiences been with replacement parts, technical support and warranty claims?
  • Overall value: Is the DuroMax worth the additional investment over the Champion? 

I'm already aware of the reported design flaw involving the DuroMax's oil access location and the inconvenience this creates during oil changes.

I'm hoping to make a purchase by today and would particularly appreciate hearing from people who own either of these exact models.

Thanks again for helping me navigate this decision!


r/Generator • • 16h ago

Any tips for a new Honda 2200i owner?

4 Upvotes

Just picked up 2 Honda 2200i companions to run my rv air conditioner microwave and charge electric dirt bikes. I am going to mostly run them in the desert and woods all year so lots of dust. Should I run them on a platform or put air filter oil on the air filter to keep dust out of the engine so they last a long time? Also I was going to use 91 ethanol free because I always have it for all the other stuff I use. Also do you guys change jetting for high altitude if it’s just for a couple days or no? Thanks


r/Generator • • 18h ago

WEN 6800 watt dual fuel generator LPG connection question

5 Upvotes

I have learned that to connect this generator to my house LPG line which already has the regulated correct pressure I must separate the diaphragm from the regulator and use the diaphragm in my connection. You can see I have already done this. Does any one out there know these tread sizes and what specific fitting I need to purchase and where I can get it? I am trying to connect the diaphragm to a 3/8" female flare connection. So I know I need a 3/8" male on one end of the fitting but I do NOT know the pipe thread size of the other male end. Please help........ Thank you


r/Generator • • 16h ago

Champion 100302 ground wire came loose

Thumbnail
gallery
3 Upvotes

Got a Champion 4000W open frame inverter (100302)

Converted it to bonded neutral and tested - working great.

Went to shut it off and the switch did not stop the gen. It ran rough, but wouldnt turn off. Even choked it and I'm sure that would have done it eventually but I got impatient and pulled the spark plug to kill it.

Troubleshot and found a ground wire hanging down from the front panel, which had a eyelet crimped on and you could see it had been cranked down onto before.

Tracing it back it goes to the ground terminal on the front of the panel, and then connects to both outlets grounds, thats it. So I assumed it originally went to the frame somewhere. (and the diagram confirms that)

I took it all back apart and believe it's supposed to go on the lower left bolt (picture 2 and 3). The frame is grounded/bare at that spot, so I think it would make sense electrically as well. And the length is perfect. Can anyone confirm?


r/Generator • • 1d ago

Northeast coastal storm

12 Upvotes

Who else is running on generator power this evening? Happy thanksgiving all. Thankful to have a setup today.


r/Generator • • 1d ago

If you were looking for a decent used generator with a honda or yamaha chinese CLONE engine, what's the maximum number of hours you'd consider acceptable for light, occasional use?

8 Upvotes

Is 1000 approaching statistical significant risk of failure/wearing out? I'd likely be running the generator under 50 hours a year. Quite possibly under 20.

I need more wattage than the entry level honda/yamahas, and don't have the budget for a 3kw+ one, so my best options seem to be like a champion/etc with a clone engine. But many have 1000+ hours.


r/Generator • • 1d ago

Duromax XP15500HXT vs Duromax XP13500iHT

7 Upvotes

I believe I’ve narrowed it down to these two generators for whole-home backup power running off NG. However, I’m not sure which unit is the better choice.

XP15500HXT: $400 less, 1500 more running watts, easier maintenance, possibly more reliable?

XP13500iHT: quieter, more weather protection, inverter.

They both are advertised as clean power…
15500 is <5% THD
13500 is <3% THD

Wouldn’t they both be safe for sensitive electronics? Is the enclosed unit worth the extra money? Am I missing or overlooking anything?


r/Generator • • 1d ago

DuroMax vs. Champion Tri-Fuel — Minnesota Winter Backup

7 Upvotes

I'm looking to purchase a portable tri-fuel generator for emergency home backup in Minnesota, primarily running on natural gas, and have narrowed it down to two models:

My biggest concern is reliable cold-weather starting and extended operation in temperatures as low as −20°F. I've contacted both manufacturers, and while neither guarantees operation at these temperatures, DuroMax provided more encouraging cold-weather guidance. Champion, however, has considerably more positive customer reviews.

I'd appreciate firsthand experiences with either model/brand (including customer service experiences), particularly regarding cold-weather performance, overall reliability and which you'd recommend. Thanks in advance for your suggestions.


r/Generator • • 1d ago

Any idea of the brand?

Post image
10 Upvotes

Looking at a property and not familiar with this one. Prolly 10+ yrs old.


r/Generator • • 1d ago

Duromax XP11000ih for $1899 Black Friday Sale!

9 Upvotes

Better get them while available if you need a dual fuel inverter generator. In the barn and ready to ship at the moment...

Duromax XP11000ih for $1899


r/Generator • • 1d ago

Solar generator recomendations

0 Upvotes

I'm looking for a low cost reliable 600 watt solar generator to run my pellet stove. Confused about what I see advertised. Will I need additional panels, etc. Any suggestions appreciated.


r/Generator • • 1d ago

How to find a job in genset servicing business?

4 Upvotes

Recently I bought one diesel 30kW generator, and I really enjoy the process of taking care of it. I would like to start learning more about servicing generators, so I can eventually do this professionally. Problem is, I don't have any formal nor professional experience in this, but just wish to learn more. How would you approach your local companies? I already sent tens of emails, but noone is answering


r/Generator • • 2d ago

Any reason to keep my 8kW generator now that a battery runs the house?

13 Upvotes

Our old 8,000W open frame is loud enough that the neighbors two houses down hear it all night :D It also burns 10+ gallons a day running the house directly. An Anker E10 with two batteries went in this fall, so in a long outage it carries the house and the generator only has to run a few hours a day to recharge it.

On our Power Dock setup the 240V generator goes into an inlet box that's wired to the #1 and #2 circuits on the dock, and our E10 handles the AC and well pump starts on its own, so I'm looking at a 240V inverter in the 5,000 to 7,000W range (something like an EU7000is), mostly for the noise and the fuel. I'll be a little sad to see the old one go, but the only reasons I can come up with for keeping it are charge rate in winter and running the house off the generator while it charges.


r/Generator • • 1d ago

Help with Generac GP6500 Model:G0076722

4 Upvotes

I am all for any ideas, I seem to not be able to fix the thing.

I purchased a Generac GP6500 over a year ago on Marketplace. Story was that the CO Monitor was bad, there are plenty of examples online of this being a cause of it not running. I was told the generator had been sitting for a while, and the hour count is 0 on it.

Got it running by putting a Honda GX390 carburetor on it (same fit). Still would not stay running, unplug one of the wires that disables the on/off button and the CO Monitor and it finally kept running. I can turn it off by turning the fuel off lol.

Now I am not getting any voltage output, I borrowed a volt meter to measure Hz from a buddy and the readings I got were crazy, it was jumping between 400 and 1,000 hz. Is it possible since the generator sat for a while that the magnetism is gone? I am assuming I need to try and replace the AVR?

I have removed the brushes and they seemed to be in good condition, and I also checked the resistance of the spindle I think? (I was using Chat GPT and it said resistance of the spindle was normal at around 56 ohms).

As you can tell, I am trying to learn about generator as I am doing this so be kind, but any help would be greatly appreciated.


r/Generator • • 1d ago

A-iPower SUA7000L 7000L Generator How to Unbond it

Post image
3 Upvotes

Can anyone guide me on how to make this generator unbonded? I have a Reliance 31406B transfer switch which just switches the hot wires, so I need to unbond this generator. I have looked behind the panel and behind the alternator cover and I don't see anything obvious. I am looking for a white wire connected to the green/yellow ground wire. Thanks for any help. Happy Thanksgiving to all.