Five units. That was the whole order - five machined frames for a pair of AI glasses, prototype round, before the board had a final stack-up.
The drawing came with a note in the corner: IP67. Not "target", not "aiming for". IP67, next to a callout for a 0.4 mm wall.
I asked what the sealing strategy was. The answer was that the seal would be handled later.
Here is the part I still think about. They were not being careless. They had a deck with a slide that said IP67, and the slide had been shown to people with money. The spec left the building before anyone had drawn a joint.
On five parts you cannot test IP67 in any meaningful way. You can dunk one and see what happens. That is not a test, that is a coin flip with a story attached afterwards. Real ingress testing needs a batch, a repeatable gasket compression, a controlled screw torque sequence, and somebody willing to cut the failed ones open.
We made the frames. Machined, anodised, shipped with a note in the box saying the gasket land was 1.2 mm wide and the screws were M1.4, which is about the smallest thread I am comfortable putting a torque spec on.
Three weeks later they came back for twenty units. Same note in the corner: IP67.
I might be wrong here. Maybe the deck needed IP67 to get the next meeting, and the meeting was worth more than a claim eighteen months out. I have done the same thing in the other direction - quoted a tolerance I knew was optimistic because I wanted the job.
But the groove is 0.9 mm deep and the foam is 1.1 mm. That is the number that decides whether the claim happens.