r/AskElectricians • • Jul 21 '23

This subreddit and where we currently are.

322 Upvotes

After much discussion about how the community should be moderated, this is where we currently are.

First I want to get this out of the way. We will not allow hate speech, personal attacks, slurs, bigotry, or anything that resembles it. Okay? Good.

People are going to post electrical questions on the internet, do their own electrical work, and fuck up their own electrical work. This process will happen with or with out this subreddit and its rules. If there is a reliable community where someone can come and get good information on a wide range of electrical topics, then to me there will be a net positive for safety.

We are going to be allowing comments from all users, BUT I urge those who are not electrical professionals to exercise extreme caution when doing so. If information is not blatantly hazardous, it will stay up. The community is going to be asked to use the voting system it is intended. If someone takes the advice of a comment with negative karma, then more than likely, they would have done the wrong thing regardless. Once corrected, leaving wrong comments up can be a learning experience for everyone involved.

I ask you to DOWNVOTE information you do not like, and REPORT the hazardous stuff. We will decide what to do from there. Bans may or may not be given and everything will be at the discretion of the mods. Again, if you are someone who is not an electrical professional, you have been warned.

Electrical professionals: We have an imperfect system for getting a little 'Verified Electrician' flair next to your name. To get verified, send a photo to the mods that has your certificate/seal/card. In this photo, have a piece of paper with your username and date written on it. Block out all identifying information. Once verified delete the image. All the cool ones have this flair.

If we have hundreds or thousands of active verified users, we will once again talk about the direction of this community. Till then, see you in the comments.


r/AskElectricians • • 9h ago

This is a sub panel that has 100amp service that runs off the main panel in house. Isn't the white and ground wire supposed to be on separate bus bars?

Post image
163 Upvotes

Electrician that did it said its fine because the garage had its own 100 amp service but it confuses me because its still runs off main panel in basement. Im installing a new breaker and outlet to run my garage door opener and need to know whether to separate white and ground or if i can just put them on same bar on right like the other break is.

Edit: I dont care that the wrong wire is ran. Pre 2008 is was completely safe and no problem with it. Dont care about code. Live in middle of nowhere. House is from 1897. This is sure as help better then what was previously there. I just needed to know if i should correct the one error and put the neutral and ground on separate bus bars and if I should move the ground bar to the left bus as well


r/AskElectricians • • 9h ago

Does this feed need to be replaced?

Thumbnail gallery
24 Upvotes

I work for a roofing company and I was inspecting this gentleman's roof and happened to notice that the feed from the power company going into his electrical mast appears to have worn off the protective coating and bare wire is exposed.

Are my assumptions correct that he should reach out to the power company and have them come replace these sections?

Thanks!


r/AskElectricians • • 5h ago

How dangerous is this water filled fluorescent tube that is leaking under a rotting ceiling?

Post image
7 Upvotes

At my work… directly above two back-stock freezers and leaking water where the tube meets the metal. It has never leaked from there before but has always leaked from the big rotting hole in the ceiling. Why it hasn’t been fixed I’m unsure. I was told to just turn off the light. Which controls all the lights in the decent sized room for back stock. I was told to “stop looking at Google” when I suggested we turn the breaker for that room off in case of a fire… boss said they’d talk to someone who they know who is an electrician but it’s been several hours, seems like they don’t think it’s a big deal. Is it? Couldn’t this cause a fire? TIA I know nothing about electrical stuff lol


r/AskElectricians • • 22h ago

Exposed wiring in my girlfriend’s bathroom. What are our options on a tight budget?

Thumbnail gallery
153 Upvotes

This is my girlfriend’s bathroom in a house built in the 1960s. The exposed wiring in the middle of the ceiling is where a bathroom heater used to be. There’s also a cable sticking out of the wall above the shower, shown in the last two photos.
I have no experience with home wiring, but this worries me, especially with it being in a bathroom. I’ve brought it up to her parents, but they say they can’t afford repairs right now and have other money priorities. I really want to help her get this addressed.
What would be the safest, most affordable way to handle this? Is there anything I could do to make it more safe temporarily like using electrical tape and covering exposed wire?


r/AskElectricians • • 2h ago

$45k rewire quote… is that the going rate or is that insane?

4 Upvotes

Recently purchased a home with same existing knob & tube that was discovered during the pre-purchase inspection. Inspector said he thinks its very minimal has probably been slowly updated piece by piece. He was correct, but he was also very wrong. Had an electrician come out for a follow-up, and he said it was 1 circuit. (He only briefly looked at the panel which has been updated/is modern and now only has 1 visible knob & tube wire) and said “it’s the kitchen outlets, Easy!” Again, wrong.

Decided to have another electrician come out for a complete, more in-depth, inspection and we both discovered there is more active K&T hidden behind the walls and floor cavities. Outlets are newer, and there is plenty of visible Romex throughout the house, but nothing
Is grounded and it looks like most of the romex was spliced to the old stuff in the basement and then concealed away above some drywall when they decided to finish the basement and put some fancy new outlets and lights down there. How nice of them.

Technician said it would probably be best to start from scratch and just rewire everything from the panel onward. and completely de-energize the knob and tube and that it would be a big job but super easy and nothing he couldn’t handle. He said I could even do it myself. The basement is all drywall, the attic is very large, open, and completely accessible, but unfortunately the main portion of the house (1 floor) is lathe and plaster.

It’s a smaller house. 1500 sq feet. 2 bedroom 1 bath. About 16 outlets give or take and probably 8-10 lights and switches. Original quote was $30k because the square footage was entered as 1200. Changed it to 1500 sqft and the quote jumped to $45,000+/-

The electrician couldn’t even believe it and said absolutely not. He basically said he wouldn’t allow that. Said it was robbery and proceeded to call his boss/dispatch. He did say it it could be pricey but we were both blown away at this price. He basically inspected the house, said this is bullshit and refused to give me the quote, and insisted I look elsewhere. He felt so bad for me. That is like, 1/6th of my home value and I’ve only made 2 mortgage payments so far. Haven’t even finished unpacking. I almost wanted to cry.

Is that normal? Is that really the cost for something like that? I understand copper is expensive but holy fuck. was willing and ready to pay $15k maybe even $20k but $45,000 seems steep and outrageous. Definitely going to get a handful of other opinions and quotes, but can somebody please make me feel better about this 😂


r/AskElectricians • • 5h ago

What am I missing here?

Post image
5 Upvotes

Good evening. Working in a house that used to be a school. My light switch is connected to a fire exit sign then a light fixture and then another light fixture in that order. I took out the fire exit sign and got rid of the wires that spliced into the fire exit sign. I rejoin the wires that went from the light switch and to the light fixtures. I've turned the breaker back on but the lights won't turn on anymore lol what am I missing? Here is a picture I know it's definitely not the prettiest but it's just to see if the reconnection would work and sadly not.

Thanks

Edit: Solved I cut off an extra inch of wire and used a bigger cap not sure if the wire were capped correctly or the copper was damaged.

Thanks for the comments.


r/AskElectricians • • 16h ago

Does this hook provide actual safety or is an accident with so much power most likely just going to be instantly fatal? I can't help but think this is more about making people feel better about doing a dangerous job than it is about safety.

Thumbnail reddit.com
37 Upvotes

To be clear I mean even if it is a remote chance to save someone with the hook I am all for it. I am just thinking that is exactly what that is a "remote chance"

I am not an electrician and no so very little about electricity, thank you for your answers in advance.


r/AskElectricians • • 2h ago

Re-Install Doorbell Transformer Cost

3 Upvotes

**Thank you all so much! What a great sub! I wasn’t expecting so many responses this quickly. All really helpful**

In my haste to modernize our home, I took down, patched, and painted many of the old electronics on the walls. One of those was the door chime/transformer, which I didn't realize that I needed in order to power our new modern camera doorbell. It's been patched and painted, but I know where it was - will the electrician have to re-run wire or is there a way to get power to the doorbell?

I'm really hoping this wasn't a $500 mistake. Battery powered isn't the worse thing in the world, but we plan to be in his home for the next 10 years.


r/AskElectricians • • 1h ago

What am I looking at here?

Post image
2 Upvotes

Looking to install a new light fixture. The newer wiring looks to be run through the older wiring through the neutral white. Don’t wanna burn my house down!


r/AskElectricians • • 1h ago

What is this?

Post image
2 Upvotes

We’ve lived in this house 2 years, and this plug has always baffled us, I’ve never seen anything like it, I also have taken the cover off to see if there are wires or anything.


r/AskElectricians • • 5h ago

Installing a new dishwasher

Post image
4 Upvotes

Hey, so I’m installing a dishwasher here because the previous owners didn’t have one for some reason and am going to run this cable to the cabinet on the left (under the sink) to install an outlet, as my dishwasher is a plug in. I’m unclear about some things and have questions.

  1. Can I just cut a hole in the cabinet to the left, install a grommet, and then run the cable through that into some sort of outlet box? Would I need to run it through a PVC pipe or something?
  2. If I pull the cable back into the wall and through to the left in the wall, it seems like the wall is thicker than normal drywall. I’m not at a stud. Can I just cut like normal?
  3. How much cable do I have to have left over to hook up to the outlet in the box?

Thank you!


r/AskElectricians • • 1h ago

Help understanding, odd three-way switch wiring

2 Upvotes

I am remodeling my upstairs from the previous remodel in the 90s. It has a three-way switch at the bottom of the stairs and the top of the stairs. I cannot wrap my head around how it is wired. It is not the standard three-way wiring diagram. I have she’s down all the wires and I am 99.9% sure that the incoming power goes directly to the light box then wire leaves the light box to the first switch and a wire from that switch to the downstairs switch anybody ever heard of this? I don’t see how it works at all, but it does any chance there’s a diagram showing this method?


r/AskElectricians • • 3h ago

EV Charging in townhouse condo

2 Upvotes

I have just had an L2 charger installed in my garage. As part of that, the panel was replaced and a load management system put in. Even so, the City inspector has said that the maximum I can have for the charger is 16 amps rather than the 40 I had been expecting.

The condo building is 4 townhouses with a single power service that is split between them, and it was built in 1980 if that's relevant. The load calculation for all four houses was 181 amps before the charger was installed.

I know the City inspectors here range from barely paying attention to extremely nitpicky, and I definitely got the nitpicky one this time. My question is what the risk really is to go higher - whether it might make sense to argue this. When i've asked, the response is basically "that's what the inspector said" which isn't particularly satisfying.


r/AskElectricians • • 9m ago

How to Dispose of Mulitple High Voltage Lithium Batteries

Post image
1 Upvotes

Just wondering how I get rid of all of these batteries I don't want. I heard you can't just throw them in the trash because that would be dangerous. I was thinking of just flushing them down the toilet, but it may clog, and I dont wanna have to put my hand in the water to get the batteries out (I dont believe in plungers). Thanks to all the electricians that can help!


r/AskElectricians • • 10m ago

Yamaha SPX900 signal comes out completely dry no matter what I do

1 Upvotes

Hi I’m not sure if this is the right place to ask about this, but I got a Yamaha SPX900 (a digital multi effects processing unit) recently and I’ve been trying to get the effects to work all day now to no avail. It seems like no matter what parameters I mess with, the signal just comes out dry. The balance is set to 100% and it’s not bypassed. It just feels like there’s no digital signal processing going on for some reason. I’ve also already gone through a factory reset and all the self test programs built in and it flagged the DRAM as ok, so I’m not sure what’s going on. If anyone knows anything about or has worked on this unit or any of the other SPX units and has any advice, I would be very grateful. Also if there is anywhere else I could ask about this that would be great to know too. Thank you


r/AskElectricians • • 1h ago

I feel like an idiot here. Not an electrician but have swapped fixtures, switches and basic stuff without too much issue before. I have a little half bath our kids leave the lights on constantly. This past weekend I bought a little light switch with one of the motion sensor timers. But I guess I did

Thumbnail gallery
1 Upvotes

r/AskElectricians • • 7h ago

Power strips questions

3 Upvotes

If a power strip has 10 ports including USB ports, is it safe to use all of the ports at once as long as the total power is within the limit of the power strip?

I'm planning to use it on my gaming PC setup so it will use quite a lot of power compared to laptops


r/AskElectricians • • 6h ago

1st EV Charger Install.

2 Upvotes

The guy that I asked electrical advice from for years is no longer around. He helped me do a lot of work on my own house from adding outlets to sub panels.

I already have a Hubble 14-50 outlet that's designed for EV charging and starting out to save some money I plan to just use the charger that comes with the car. But in the future I want to add a Tesla Wall Charger.

My run is about 100' +/- 10' or so. I'm going to install 1" Conduit (Not sure if I'm going to do PVC or EMT yet) through the crawl space under my house to my garage. Then use 3x #6 THHN and 1x #8 THHN (ground) and use a 60A breaker to meet the 125% overhead.

I have the option to go through the attic but I think the heat in the summer may push me to #4 which it's starting to get real expensive. The attic run is the easier run but to keep costs down I'm going the hard route.

Does this sound reasonable?

I the one response I got in another subreddit asked if I had calculated my existing load. If I had all appliances running at the same time at their max current draw I'm a little over 100A of 240v and another 20A or so of 110v if everything in the house were on at the same time. I'm also removing 2 30A 240v circuits that were once used for Window units.


r/AskElectricians • • 6h ago

What type of light system is this

Post image
2 Upvotes

I moved into my current apartment two years ago, and these types of light bulbs were already installed in every room. Lately, three out of the four have stopped working. How can I fix or replace them?


r/AskElectricians • • 3h ago

Which generator is compatible with my GenTran transfer switch?

Thumbnail gallery
1 Upvotes

I asked ChatGPT but can’t verify. The GenTran I have is 5,000w, 20A L14-20 inlet, more info in the pictures. The recommended generator is WEN DF680iX Quiet 6800-Watt Dual Fuel Inverter but it’s 30A L14-30R output. It suggested using ParkWorld 885255 L14-30P to L14-20R adapter cord. Is it safe to use? This has been exhausting trying to figure out. Are there any other compatible inverter generators, if not?
Thank you in advance!


r/AskElectricians • • 3h ago

Home Electrical Question

Thumbnail reddit.com
1 Upvotes

Hello, I had a question regarding how to get a mini split on a breaker box that is too small.


r/AskElectricians • • 3h ago

Is there a better way to replace this light or do I just strip a wire and wingnut it again?

Thumbnail gallery
1 Upvotes

I noticed there’s no ground wire which I’m assuming is in a junction box on the other side of the can wall? Please help me not burn my house down.


r/AskElectricians • • 14h ago

6-6-8 CU SEC alternative?

7 Upvotes

I am installing an EV charger (60 amp circuit) in my garage. The run is roughly 60 feet. I'd planned on using 6-6-8 CU SEC since it can handle the full 48 amp constant charging load. The problem is, most places do not carry this wire or they want me to purchase 500'.

Is there any alternative that is more common that will not cost me $500+?