r/AskElectricians • • Jul 21 '23

This subreddit and where we currently are.

322 Upvotes

After much discussion about how the community should be moderated, this is where we currently are.

First I want to get this out of the way. We will not allow hate speech, personal attacks, slurs, bigotry, or anything that resembles it. Okay? Good.

People are going to post electrical questions on the internet, do their own electrical work, and fuck up their own electrical work. This process will happen with or with out this subreddit and its rules. If there is a reliable community where someone can come and get good information on a wide range of electrical topics, then to me there will be a net positive for safety.

We are going to be allowing comments from all users, BUT I urge those who are not electrical professionals to exercise extreme caution when doing so. If information is not blatantly hazardous, it will stay up. The community is going to be asked to use the voting system it is intended. If someone takes the advice of a comment with negative karma, then more than likely, they would have done the wrong thing regardless. Once corrected, leaving wrong comments up can be a learning experience for everyone involved.

I ask you to DOWNVOTE information you do not like, and REPORT the hazardous stuff. We will decide what to do from there. Bans may or may not be given and everything will be at the discretion of the mods. Again, if you are someone who is not an electrical professional, you have been warned.

Electrical professionals: We have an imperfect system for getting a little 'Verified Electrician' flair next to your name. To get verified, send a photo to the mods that has your certificate/seal/card. In this photo, have a piece of paper with your username and date written on it. Block out all identifying information. Once verified delete the image. All the cool ones have this flair.

If we have hundreds or thousands of active verified users, we will once again talk about the direction of this community. Till then, see you in the comments.


r/AskElectricians • • 14h ago

My electric bill drops whenever my neighbor goes on vacation. Could our apartments be sharing a circuit?

124 Upvotes

I rent the upstairs unit in an old house that was split into two apartments. my downstairs neighbor works out of town for a week at a time. we got to talking about bills because mine is usually higher, even though he has the bigger place. my app shows daily usage, so out of curiosity I looked at the last two months. I usually use around 8–10 kWh a day. both weeks he was away, it dropped to around 4–5. I work from home and my routine was pretty much the same. the part that got me was that I went away for a weekend while he was home, and my usage barely moved. tthere are two meters outside. The washer and dryer are in a shared basement, and I just realized I have no idea who pays to run them. He’s as curious as I am and said he’s happy to compare bills. if you were called out for this, what would you check first? or is there anything worth documenting besides the usage graphs before I ask the landlord to send an electrician?


r/AskElectricians • • 22m ago

Trying to route Ethernet from downstairs, do I give up and call an electrician?

Thumbnail gallery
3 Upvotes

Hello everyone. I don’t mind doing a little handiwork and I’ve heard routing Ethernet is fairly straightforward especially with an unfinished basement. But, I used an air vent near where I want the outlet/keystone to determine where the hole would have to go and I’m pretty sure it would go straight through one of the floor joists and through a section of drywall. In the first picture, the joist (?) under the air duct aligns basically perfectly with the wall in the 2nd picture. Am I wrong in thinking the wire would go straight through it or is there some other way around it? Please advise. Thank you.

PS: ignore the wire mess in the 2nd picture, it’s from the computer.


r/AskElectricians • • 5h ago

Why is everything branded?!

7 Upvotes

I am replacing toggle switches with paddle switches and adding some dimmers. Legrand Lutron, Leviton all have embossed logos. Can any electricians recommend switches that don't have branding but are good quality?


r/AskElectricians • • 1d ago

In middle of home reno, electrician saying we need whole home rewired .. curious what you all think?

Thumbnail gallery
1.4k Upvotes

r/AskElectricians • • 6h ago

What should I do about this outlet?

Post image
8 Upvotes

I really would like to plug in my washer, but this outlet is not something I have ever dealt with before. Should I buy an adapter? Not too sure what to do tbh


r/AskElectricians • • 2h ago

Breaking into the industry

4 Upvotes

How did you guys start your career as an electrician? Any advice you can offer for someone trying to build a career in the industry? Im tired of working my current job but I can’t land an apprenticeship anywhere cuz every employer wants minimum of 2-3 years experience. I’m on the list for the union but I fear it’ll be a while before I get the call.


r/AskElectricians • • 10h ago

Transformer Mounting

Post image
14 Upvotes

wondering if adding this second transformer is overloading the drop in anchors currently supporting the existing 75kva

Total weight :1050lbs

3/8 drop in anchors with 3/8 threaded rod being used

75kva 600 lbs
45kva 400 lbs

rating of anchors ~ 500 lbs each.

I know on paper nothing is near being too heavy but i’m still a bit uncomfortable with it.


r/AskElectricians • • 8h ago

Issue with homeline tandem breaker

Post image
9 Upvotes

I ordered a 15a tandem homeline breaker from Home Depot. I received it and tried to install it but it would not seat properly in the panel. I compared it to the standard -5a breaker that I removed and the slot in the plastic isn’t as deep in the tandem breaker. I thought I got a bad casting so I went back to Home Depot to get another one and everyone in the box was the same. Even the 20a tandems were not he same. What should I do?


r/AskElectricians • • 1d ago

Accidentally drilled into a wire while mounting a TV. Homeowner is now claiming over $7,000 in electrical and appliance damage. Electricians, what are your thoughts?

1.7k Upvotes

I’m a low-voltage contractor in Georgia and recently encountered a situation that I’d like some professional insight on from experienced electricians.

A couple of weeks ago, I was mounting a TV for a customer. During the installation of a receptacle behind the TV, my drill accidentally struck an electrical wire inside the wall, causing a breaker to trip. I fully acknowledge that I struck the wire and am not trying to deny that happened.
However, what happened afterward is what I’m struggling to understand.

Background:

  • The home was built within the last 10 years.
  • The homeowner previously experienced an electrical incident involving a bug zapper and had another electrical company come out to perform repairs. I believe they ended up needing to replace a breaker but I’m not entirely sure exactly what happened.
  • Following my incident, I hired an electrician to investigate.
  • The electrician discovered defective breakers in the electrical panel.
  • He also discovered that the grounding wire outside the home was broken, disconnected and essentially dangling alongside the house.
  • My understanding from speaking with the electrician was that my incident exposed preexisting electrical issues.
  • The power company also came out and addressed an issue on its end, although I do not currently know exactly what they repaired.
  • According to the homeowner, even after these repairs, the affected wall remained without power and required additional repairs. The electrician I hired refutes this and says everything was working when he left.

I voluntarily paid the electrician’s $250 diagnostic fee. The homeowner initially requested that I contribute $400 toward the situation. I offered $200 and a complimentary TV remount. She accepted the $200 and declined the remount.

Fast-forward to today, and the homeowner is now formally disputing the electricians invoice and claiming the following damages:

  • Damage to both furnace systems: $3,050
  • Garage door equipment: $762
  • Electrical repairs: $2,880
  • Washing machine repairs: $360
  • Damaged lighting: $80

Total: $7,132

She also claims that she is still without heat, continues to discover damaged electrical equipment throughout the home and may pursue a formal claim against me.
Her argument is that regardless of the preexisting electrical issues, my drill striking the wire triggered the chain of events and therefore I should be financially responsible for the resulting damages.
I’m not an electrician, and I’m genuinely trying to understand the electrical theory behind what happened. I have no problem taking responsibility for damage that I actually caused, but I’m struggling to understand how striking a single branch circuit wire could cause widespread damage to appliances on multiple unrelated circuits throughout an entire house.
My questions for the electricians here:

  1. In a properly functioning electrical system, would striking a wire with a drill typically cause anything beyond localized wire damage and a tripped breaker?
  2. Could defective breakers and a disconnected grounding electrode conductor explain this extent of appliance damage?
  3. Does this sound more consistent with a compromised service neutral, an overvoltage event or another electrical issue?
  4. Could striking a branch circuit wire initiate an overvoltage event if there were preexisting electrical deficiencies?
  5. Is it possible that the previous bug zapper incident compromised the electrical system and that the previous electrical contractor failed to identify the extent of the damage?
  6. Could improper wiring or installation during the original construction of the home have contributed to this situation?
  7. Have any of you encountered a similar situation where a relatively localized electrical fault caused widespread appliance damage?
  8. If you were investigating this incident, what would you look for to determine the actual root cause and distinguish newly caused damage from preexisting conditions?
  9. From a professional standpoint, how would you approach determining responsibility between myself, the previous electrical contractor, the original builder and potentially the power company?
  10. Would you recommend hiring an independent forensic electrical engineer to investigate?

I understand that Reddit isn’t a substitute for legal counsel, and I’m not necessarily looking for legal advice. I’m primarily interested in understanding the electrical failure mechanism, hearing from people who have encountered similar situations and determining what my next steps should be.
I appreciate any insight.


r/AskElectricians • • 3h ago

Sconce wiring diagram

Post image
3 Upvotes

I’m surprising my wife for Christmas with an accent wall in our bedroom and want to add some DIY hardwired sconces from the outlets by each of our bed side. I found one I like but I’m looking at the diagram and having trouble understanding it. I understand the wiring, it’s the mounting that’s confusing me. Is this bracket supposed to attach to a junction box and if so what type of box should I be buying? Does the installation even require a box? Looking for someone with more expertise to provide it, thanks!


r/AskElectricians • • 1h ago

School project

Thumbnail gallery
2 Upvotes

I decided to create a circuit that would turn on the fan in the circuit when the thermistor reached a certain temperature. I initially tried it on a breadboard and it worked, then soldered it but the result always fails, even though I have changed the potentiometer value, the fan continues to run. Can anyone here help with my problem? (Note: some components such as mosfets and I removed the fan because I wanted to test it on a breadboard.)


r/AskElectricians • • 4h ago

Replace breaker or panel

Thumbnail gallery
3 Upvotes

r/AskElectricians • • 10h ago

Electricians please help !

Thumbnail gallery
8 Upvotes

My compressor requires more power than the basic outlet …can I buy a cord that’s for a stove and add a 20 amp outlet so I can plug in my compressor. I’m going to plug it into the stoves outlet at night when I need to work with the compressor.


r/AskElectricians • • 1m ago

Anyonem

1 Upvotes

So about five hours ago I was cooking steak. I had one hand on the metal sink. And flipped my steak with a fork on my electric stove. I felt both my elbows vibrate, and I thought it was my anxiety, so I went to flip the other steak and it happened again both my elbows vibrated the question is, should I go to the hospital if I feel fine? Because It went hand to hand?

And also wtf would cause this


r/AskElectricians • • 10h ago

Do I really need dedicated circuits for my gas stove and microwave?

6 Upvotes

An electrician told me my microwave and gas stove/oven need separate dedicated circuits due to a safety issue with the existing wiring.

The proposed work is to separate the existing 15-amp circuit and install dedicated 20-amp circuits for both appliances. The quote was $3,577.

My stove is gas, so I’m wondering if this is truly necessary from a safety standpoint, or if the issue is mainly that they’re sharing a circuit. Would not running them at the same time make any difference?

I’m also getting a second opinion, but I’d appreciate any insight!


r/AskElectricians • • 4h ago

where to ground well casing grounding conductor?

Thumbnail gallery
2 Upvotes

Hi all,

Hopefully this question belongs here and not in plumbing.

I recently replaced our broken well pump and pressure tank. When removing the old tank, I noticed that there was a thick ground wire clamped to the metal tube (see red circle, first picture) from the tank. Googling it tells me it's well casing grounding wire.

When replacing the tank, I decided to redo the plumbing with CPVC instead of metal tubing, since the rest of the in-house plumbing was done with CPVC (see second picture; where I cut off the pipe in the first picture is the beginning of the CPVC).

The problem is, now I don't have metal tubing to ground the wire. It is currently wire-nut onto the grounding wire of pressure switch/pump connection.

My question now is, where should I ground this wire to code? Should I use the same clamp to clamp it onto the tank tee?

Thank you in advance!


r/AskElectricians • • 1h ago

3 Way Switch Help

Post image
1 Upvotes

r/AskElectricians • • 4h ago

Quick safety question after panel replacement

2 Upvotes

I just had my panel replaced, permitted and inspected. Two nights ago the lights in my bedroom wouldn't turn on, went to the panel and the breaker was NOT tripped. I turned it off and on again though and the lights in my bedroom worked again. Happened again tonight.

I already let the electrician know. I'm a bit paranoid and wanted another opinion if it was safe to keep the breaker on? Or should I turn it off and sleep on the couch till someone can come to check it out?


r/AskElectricians • • 18h ago

Wanted to share a dangerous situation I found

Thumbnail gallery
26 Upvotes

We just moved into our house a few weeks ago. Over the weekend I was sitting in front of my office desk, not working on the computer, when I noticed it turn off along with the printer and some LED lights, all plugged into the same receptacle. I checked voltage in that receptacle and there was no power. I checked the breaker and it was on. I was lazy so I just checked the receptacle in my office that was easiest to reach. I moved the probes around a bit and a few things happened. I got 120V, my computer turned back on, and I noticed sparking on one of the neutrals. I turned off the breaker and opened it up, and the first photo is what I found. If you look closely you'll notice the neutral is wrapped in the wrong direction...

I was planning on upgrading all of the plugs and switches anyway, but I think I might move that project up on the list... As an aside, I am a Journeyman Electrician, Red Seal (haven't gotten verified yet), but I haven't done any residential or commercial professionally. Plugs and switches I can handle...

As an aside, the second photo shows another scary situation I found....


r/AskElectricians • • 1h ago

Solder won’t melt

0 Upvotes

Hey guys, I’m pretty new to soldering and I’m trying to fix an Acer Nitro XV272U monitor I bought for $50. It keeps power cycling every 2-3 seconds, so I figured I’d try replacing the capacitors.

The problem is that I cannot get the original solder to melt no matter what I do.

I’m using a YIHUA 926LED III. I’ve tried temperatures between 350-380°C, bought new chisel tips, cleaned and tinned them, and tried adding fresh solder. The fresh solder melts perfectly fine, but the original solder doesn’t seem to melt at all, even after holding the iron against it for 15+ seconds.

The capacitors are 330uF 35V, and the power supply board is 715GB193-P02-000-0HGY.

I’ve already spent more money than I wanted to on this, so I’m hoping there’s something I can do with what I currently have.

Any advice would be appreciated.


r/AskElectricians • • 1h ago

School project

Thumbnail gallery
1 Upvotes

I decided to create a circuit that would turn on the fan in the circuit when the thermistor reached a certain temperature. I initially tried it on a breadboard and it worked, then soldered it but the result always fails, even though I have changed the potentiometer value, the fan continues to run. Can anyone here help with my problem? (Note: some components such as mosfets and I removed the fan because I wanted to test it on a breadboard.)


r/AskElectricians • • 1h ago

Who install a whole-home generator near Clifton Park and what does it cost?

1 Upvotes

We lost power for two days in February, and the basement almost flooded when the sump pump stopped. Now, I'm looking at a standby generator.

I've seen people say $15k to $17k all-in for a 26kW unit. What's in the rest besides the generator? Transfer switch, gas line, permits, panel work?

And do I need the whole house covered, or just heat, sump pump and fridge?