r/AskElectricians • • 14h ago

Accidentally drilled into a wire while mounting a TV. Homeowner is now claiming over $7,000 in electrical and appliance damage. Electricians, what are your thoughts?

490 Upvotes

I’m a low-voltage contractor in Georgia and recently encountered a situation that I’d like some professional insight on from experienced electricians.

A couple of weeks ago, I was mounting a TV for a customer. During the installation of a receptacle behind the TV, my drill accidentally struck an electrical wire inside the wall, causing a breaker to trip. I fully acknowledge that I struck the wire and am not trying to deny that happened.
However, what happened afterward is what I’m struggling to understand.

Background:

  • The home was built within the last 10 years.
  • The homeowner previously experienced an electrical incident involving a bug zapper and had another electrical company come out to perform repairs. I believe they ended up needing to replace a breaker but I’m not entirely sure exactly what happened.
  • Following my incident, I hired an electrician to investigate.
  • The electrician discovered defective breakers in the electrical panel.
  • He also discovered that the grounding wire outside the home was broken, disconnected and essentially dangling alongside the house.
  • My understanding from speaking with the electrician was that my incident exposed preexisting electrical issues.
  • The power company also came out and addressed an issue on its end, although I do not currently know exactly what they repaired.
  • According to the homeowner, even after these repairs, the affected wall remained without power and required additional repairs. The electrician I hired refutes this and says everything was working when he left.

I voluntarily paid the electrician’s $250 diagnostic fee. The homeowner initially requested that I contribute $400 toward the situation. I offered $200 and a complimentary TV remount. She accepted the $200 and declined the remount.

Fast-forward to today, and the homeowner is now formally disputing the electricians invoice and claiming the following damages:

  • Damage to both furnace systems: $3,050
  • Garage door equipment: $762
  • Electrical repairs: $2,880
  • Washing machine repairs: $360
  • Damaged lighting: $80

Total: $7,132

She also claims that she is still without heat, continues to discover damaged electrical equipment throughout the home and may pursue a formal claim against me.
Her argument is that regardless of the preexisting electrical issues, my drill striking the wire triggered the chain of events and therefore I should be financially responsible for the resulting damages.
I’m not an electrician, and I’m genuinely trying to understand the electrical theory behind what happened. I have no problem taking responsibility for damage that I actually caused, but I’m struggling to understand how striking a single branch circuit wire could cause widespread damage to appliances on multiple unrelated circuits throughout an entire house.
My questions for the electricians here:

  1. In a properly functioning electrical system, would striking a wire with a drill typically cause anything beyond localized wire damage and a tripped breaker?
  2. Could defective breakers and a disconnected grounding electrode conductor explain this extent of appliance damage?
  3. Does this sound more consistent with a compromised service neutral, an overvoltage event or another electrical issue?
  4. Could striking a branch circuit wire initiate an overvoltage event if there were preexisting electrical deficiencies?
  5. Is it possible that the previous bug zapper incident compromised the electrical system and that the previous electrical contractor failed to identify the extent of the damage?
  6. Could improper wiring or installation during the original construction of the home have contributed to this situation?
  7. Have any of you encountered a similar situation where a relatively localized electrical fault caused widespread appliance damage?
  8. If you were investigating this incident, what would you look for to determine the actual root cause and distinguish newly caused damage from preexisting conditions?
  9. From a professional standpoint, how would you approach determining responsibility between myself, the previous electrical contractor, the original builder and potentially the power company?
  10. Would you recommend hiring an independent forensic electrical engineer to investigate?

I understand that Reddit isn’t a substitute for legal counsel, and I’m not necessarily looking for legal advice. I’m primarily interested in understanding the electrical failure mechanism, hearing from people who have encountered similar situations and determining what my next steps should be.
I appreciate any insight.


r/AskElectricians • • 11h ago

In middle of home reno, electrician saying we need whole home rewired .. curious what you all think?

Thumbnail gallery
253 Upvotes

r/AskElectricians • • 17h ago

Melted wire in junction box for EV charger

Thumbnail gallery
70 Upvotes

Our level 2 EV charger (Emporia) just started giving us a temperature error.

I turned off the breaker and checked the junction box.

Inside, looks like the black wires had melted.

This was professionally installed by electricians less than 2 years ago.

Do you see obvious errors?

I’m wondering if I should go to the same company, and/or hold them responsible for shoddy work.


r/AskElectricians • • 14h ago

Not understanding this graphic showing how to wire a switch at the end of a run

Post image
32 Upvotes

I’m wiring a basement room and want to have a ceiling fan as well as four can lights. This switch would be for the can lights. What I had planned to do was to run 12/2 down from one of the fixtures and use the black as the hot wire running down from the supply and the white as the hot wire running back up to the light (labeled with black electric tape to denote it as being used as a hot wire). Then I’d run 12/2 off of the first fixture to the other three. But I am looking at the Black and Decker ultimate guide to wiring, and it says that’s the old way and I’m supposed to do it like the picture shows, which makes zero sense to me. What am I missing?


r/AskElectricians • • 9h ago

Question about wiring in to main panel

Thumbnail gallery
5 Upvotes

First off, thank you for looking/helping. I really appreciate any help you can give. So I had a 240v installed in my garage. My question is... does this setup look ok? Should there be some type of cable clamp going in to the panel and in to the junction box? Would this pass inspection (Florida)?

Edit: Thanks to you all! The box was originally a 50 amp ev plug and then changed to go to the charger. Can anyone also link the products I would need to get to fix this....


r/AskElectricians • • 15h ago

What is this type of electrical wiring is this called? And what are the metal plates for?

Thumbnail gallery
5 Upvotes

Thanks! 😊


r/AskElectricians • • 15h ago

Is this considered safe or unsafe please? It still works. Only that plastic shell seems to be cracked. IKEA.

Thumbnail gallery
5 Upvotes

Thank you.


r/AskElectricians • • 5h ago

House centipede hiding spot!!!

Thumbnail gallery
3 Upvotes

Decided to change out a light switch since it has been making sparking sounds…. Now I I know why.


r/AskElectricians • • 5h ago

Distribution Board confusion

Thumbnail gallery
3 Upvotes

Can someone educate me why my AC outlet is connected through the 3rd switch from the right (the blue one). Why there are 2 distinct blue ones on my DB and I can't seem to locate the outlet(s) allocated for "SACU" from my DB. I'll attach photos for your references. Thank you


r/AskElectricians • • 10h ago

How much would this cost

Post image
3 Upvotes

Mods let me know if these post aren’t allowed.

Not exactly looking for a quote but a rough estimate so I know what the ballpark I’m dealing with here. It’s for a property recently brought that needs some work prior to service being turned on.


r/AskElectricians • • 11h ago

4 years old Electric oven fire

3 Upvotes

We had a small fire in the oven with two chicken drumsticks, the house didnt burn down because we switched off and waited for it to calm down.
The oven is around 4 years old.
Can you tell me what to do next? And Why was there fire?

  1. tray with two drumsticks and a bit of oil placed on top drawer, so high that it was almost touching the grill
  2. grill option was ON on high temp
  3. Oul started splashing around and caused small explosions and we saw fire

Is the Oven broken? Is it normal?

Shall I buy new oven or clean this one and turn on again like nothing happened?
Thank you electricians !


r/AskElectricians • • 12h ago

If one cut the plugs off this, strip the wires a bit and attatch alligator clips to bite onto 12v battery. Could that be used to perform actuating tests for electrical car parts diagnosis?

Post image
3 Upvotes

These are rated for up to 1000 volts and the pins say 20 amp. Any of the parts i would be testing use within 5-15 amp fuses.

$7.99 nearby and available today as opposed to buying a spool of wire, spade connector and alligator clips which would all come out to about $30. Preassembled test leads not immediately available in my area would need to order online and wait for shipping.

Theoretically im assuming i could just use alligator clips and some scrap wire but i dont have those anyway, and dont know enough about this to confidentally rig my own leads up today.


r/AskElectricians • • 12h ago

Old Recessed Can Lights

Post image
3 Upvotes

Hello! Just wondering for my own curiosity…what is this circled in the photo? These are old recessed can lights that we are doing a retrofit kit in. Had an issue with one flickering on/off and believe this is the culprit.


r/AskElectricians • • 13h ago

Complete beginner, 2 weeks to learn electrician's helper basics (Luxembourg/EU): what should I focus on?

3 Upvotes

Hi everyone,

I'm looking to work as an electrician's helper through temp agencies in Luxembourg. I have no electrical background, but I'm reliable, physically fit, and ready to learn fast. I'm giving myself about 2 weeks to get the basics so I can be useful on site and pick up small jobs.

I know I won't be doing anything on live circuits and I'm not trying to pass myself off as an electrician. I just want to be a helper who knows what he's doing and doesn't slow the crew down.

A few questions:

  1. What basic skills should I have to be a useful helper? (pulling cable, conduit, cable trays, stripping wire, terminating, etc.)
  2. What theory is worth learning first? (Ohm's law, phase/neutral/earth, RCDs/breakers...)
  3. Which tools should I know how to use and recognize (multimeter, drill, wire strippers...)?
  4. What safety knowledge or certificates do employers expect from a beginner? (working at height, basic H&S, first aid...)
  5. Any good resources or YouTube channels for learning fast? Or ways to get hands-on practice (small projects, volunteering, shadowing)?
  6. What would you look for in a helper on day one, and what mistakes do beginners make that I can avoid?

Just so you know, I'm in Europe (230 V, IEC/EN standards, not NEC), so please keep that in mind if you're from North America.

Thanks a lot for any advice!


r/AskElectricians • • 22h ago

Getting High Voltage Occasionally ~260v+, need advice to overcome it

3 Upvotes

Our home/neighborhood is getting high voltage occasionally and it is damaging the electronic equipment like CCTV, Inverter, Fans etc.

Need advice if I can install this (below link), so that it can cut off the under or higher voltage, I know it wont stabilize it, but my primary goal is to protect my devices from high voltage for the entire home.

pls share your valuable suggestions.

https://www.amazon.in/dp/B0HF42W356/?coliid=I11N63PDSRJ7XC&colid=2KE7YHERD4XOC&psc=1&ref_=list_c_wl_lv_ov_lig_dp_it


r/AskElectricians • • 46m ago

Why do you call it Single-Phase?

2 Upvotes

Single Phase 208: two 120v phases at 120 degrees.

Three Phase 208: three 120v phases at 120 degrees.

I'm a FSE for a Japanese equipment manufacturer that uses Austrian made accessories. I regularly need to communicate facility power requirements before and during installs. I have no idea how to communicate to the Union electricians at the Plant or Lab I am working in that I need actual 200v Single phase without feeling like I am speaking Martian.


r/AskElectricians • • 4h ago

What’s going on?

Thumbnail gallery
2 Upvotes

So I’m certain everyone here will call me dumb which I am admitting that I am but I am curious what exactly is going on when I plug things into this plug and literal blue red and yellow flames are coming from around the seams of this plug? I’d try to take a video of it but I’d rather not play with fire in a house I’m sleeping in. This isn’t the first or fifth time it’s happened and I’ve ignored it😩


r/AskElectricians • • 6h ago

Best and most cost-effective way to restore power to a detached shed?

2 Upvotes

I have a detached shed about 40 feet from my house that is already wired with lights and receptacles, but currently isn’t receiving any power.

I’ve located where the existing electrical wire comes into the shed from underground, but large tree roots have grown over it, making it nearly impossible to dig up and trace back to where it enters the crawl space. I’m also unsure whether it’s still connected to the breaker panel.

I’m considering running a new electrical line from the house. I have some shipboard electrical experience and some basic handyman experience, but I’m by no means a residential electrician.

Would it make the most sense to dig the trench myself and have an electrician handle the actual wiring and connections? Or would it be worth having someone troubleshoot the existing wiring first?

Unfortunately, I don’t have a huge budget to throw at an electrician, so I’d like to do as much of the labor myself as reasonably and safely possible, or all of it if feasible.

I’m feeling a little overwhelmed by all the different ways to approach this. What would you guys recommend, and what would be a reasonable ballpark cost?

Thanks in advance!


r/AskElectricians • • 6h ago

New Light

Thumbnail gallery
2 Upvotes

i’m installing a new ceiling light but a little stumbled could anyone help out ? The grey wires in the ceiling are definitely the hot wires right and i would just cap a white a black because the new light has one connection.


r/AskElectricians • • 9h ago

Ant reason to not install within panelboard?

Post image
2 Upvotes

I have an hepd80 surge suppressor that is supposed to mount through a 3/8" KO. I dont really want to cut through the drywall to install this and replace it in the future. I have enough space withing the gutter of the panel to install it. Is there any reason that it cannot go inside the panelboard? Any tips to mount it?


r/AskElectricians • • 9h ago

Do I need to remove old wiring if replacing it?

2 Upvotes

Sorry in advance for possibly a simple question. I am replacing old rotting Romex in older home. In some instances I am running a new path to existing fixtures instead of following the original wiring because its easier. Can I leave the old wiring in place disconnected at each end? Do I have to label or mark it in some way?


r/AskElectricians • • 9h ago

Lights flickering when it’s cold

2 Upvotes

Whenever it gets cold, the garage lights flicker.

I didn’t think much of it. Just figured it was because the builder installed cheap led lights. So I finally got around to changing them out with some new Govee lights for the Holiday seasons. Same with the some kitchen lightening since they started flickering.

The garage lights and kitchen lights are two different circuits. Only two lights in the kitchen flicker.These are drop down lights above the sink/bar.

Both I replaced both lights with Govee branded lights. Assuming these are good quality, I am not sure what else can be causing the issue.

Should I replace the switches? Kitchen has a dimmer, garage does not.


r/AskElectricians • • 11h ago

Breaker box hums when heater kicks on

2 Upvotes

Basically title. The hum is brief, maybe 6 seconds or so. Starts at low volume and then tapers off completely. Replaced the breaker for the heater, no change. Thinking to replace the main breaker now?


r/AskElectricians • • 11h ago

Is there something special about this outlet? The 8 wire holes…can I replace it with the in the second picture?

Thumbnail gallery
2 Upvotes

I cant find any like it at the big stores