r/AskElectricians • u/iamthefalcon • 10h ago
Extra wires from outlet?
I’m replacing an outlet and see these extra wires. Why would these be there?
r/AskElectricians • u/iamthefalcon • 10h ago
I’m replacing an outlet and see these extra wires. Why would these be there?
r/AskElectricians • u/Ralph4000 • 4h ago
The bottom component is from a RBG LED light strip, and the top part is 2 wires coming out of my table P.O.P. which give out 9V for lights. I changed my basic yellow light for this rgb one and I guess I might’ve cut my wire too short. Thoughts and solutions?
r/AskElectricians • u/GalactoidTetris • 4h ago
I'm using a surge-protected multi-plug socket that looks a bit like this:

I connected the sockets to my desktop computer: one to my monitor, another to my Sound Blaster, and the last one to my computer (which goes into the Power Supply Unit [PSU]).
It is rather new, at 7 months old.
I typically turn off switches in the multi-plug socket after I shut down my computer.
Each switch has an orange LED indicator when I turn it on.
However, recently, I noticed that when I'm in a dark room and turn it back on, the switch corresponding to the PSU has a brief, split-second white flash, where the light goes through the slits in the switch. This is not the orange LED indicator light.
It made no smell or sound. I can then use my computer all day without issues.
However, this spooks me. Should I be concerned about this brief split-second white flash?
Thanks!
r/AskElectricians • u/Colifama55 • 19h ago
Just bought a house and wanted to replace the carpet with laminate flooring. After removing the carpet, we discovered a brown wire that ran from the garage through the living room to the house’s back wall. In the garage, it goes up into the ceiling and disappears. When you go to the backyard it is nowhere to be found.
The house has an old security system and I’m wondering if it’s related to that. Another similar wire appears to have been cut as well. Any advice on figuring out what the wire is for and if it can be safely removed?
Thanks in advance.
r/AskElectricians • u/Dbshelton • 1h ago
I live in a large barndominium that has a Main 200amp panel feeding 5 sub panels. All of the sub panels have bonding screws. Should I remove the screws from all of the sub panels? Also have a 50amp generator feed panel that is connected to the Main with an interlock. The generator is unbonded.
r/AskElectricians • u/xander1900 • 1h ago
Hello! I need some help to identify which is the live wire and which is the neutral wire on this ceiling lamp. A lamp store, via the same photo, mentioned it doesn’t matter and I can just install it with one wire matching the brown wire and one the blue from my ceiling fixture. I still have doubts due to the one wire having two wires attached to one another and just wanted to see if folks here could help me out! Thank you so much!
r/AskElectricians • u/irmarbert • 16h ago
I’ve got a run I need to do off my main panel.
About sixty feet out to two structures.
First structure is a small sauna and requires 240v/50a. That’s all it needs. It’s 50ft from main panel. Half of that run is going to be under the house.
Second structure is 10-12 feet beyond first structure and is about 130sqft. It will need a small sub panel that can handle a 240v/15a mini split, and then a 120v circuit for 15a outlets.
Could the 240v be done in a single run and feed both structures? Like, have a junction at the first structure that feeds it and continues on to supply the second structure? Could that 240v run to the second structure be used to supply both the 240v and 120v breakers in the second structure? I guess like you have at a main panel. Can a sub panel be set up like that?
Thanks!
r/AskElectricians • u/Tun_Ra • 12h ago
I told my girlfriend's mother I would help fix her switches in the house thinking it would be an easy task. The switches she got are the new ones with the locking switches as opposed to the old screw type. However when the house was wired it looks like a lot of the wires were daisy chained together preventing me from just doing a quick switch. Would the best practice just be to take all the switches out and use individual wires connecting back to the original wire with a wire nut?
r/AskElectricians • u/ColdCovfefe-n-Cream • 22h ago
Hey everyone,
My son is graduating as an electrical technician, and I'm looking for some unique and practical Christmas gifts as he prepares to start his career.
I'm not necessarily looking for the standard tools that most electricians acquire during their training. I'm more interested in those hidden gems, specialty tools, gadgets, accessories or clever trade hacks that experienced electricians have discovered over the years and now can't live without.
Maybe it's something that saves you time, makes a frustrating job easier, fits perfectly into your pocket, or something you wish someone had given you when you were first starting out.
It doesn't have to be expensive, either. Sometimes the best tools are the inexpensive ones nobody tells you about.
I'd love to hear your recommendations, including specific brands or models if you have a favorite.
Thanks in advance for sharing your experience and helping a young guy get off to a great start!
r/AskElectricians • u/Unable_Mongoose • 10h ago
I live in a 60+ year old multi-story condo building and one of our elevators went down. Elevator tech says it's a electrical problem. The electrical company usually use was booked out 7-10 days so they called another electrician. I tagged along just to see what was going on and while I have some knowledge of residential electric, I have much less experience with 3-phase.
As I understand things the power comes into the building as 480v 3-phase into large disconnect on one floor, from there power goes to another floor with 7 fused disconnects, 7 transformers, that step the power down to 120/240v, onto meter panels for every unit and common areas. With the exception of the conduit that leads from the disconnects to the transformers and from the transformers to the meter panels, all the conduit disappears into walls/floors so it's difficult to see what leads where.
The electricians test at the fused disconnect for the for elevators. One phase is dead, 500v between the two good legs and between each leg to ground, all the fuses are good. They made some comment about 277v, which as I understand it would be 480 Wye but I didn't see a neutral in the disconnect and to the best of my knowledge there's nothing in the building at uses 277v. Which kind of makes me think we have a 480v Delta. They also said something about the transformers stepping up power from 120, /240 to 480, which makes no sense. They were both young guys and I think a little out of their element. They left saying its a POCO problem with the transformers. With the holiday the POCO has been a little slow in responding...
I'm just trying to get a better understanding of what's going and if anyone could provide some guidance, it would be very much appreciated.
Thanks for reading this long post!
r/AskElectricians • u/definitely_aware • 11h ago
r/AskElectricians • u/drubird_ • 15h ago
So I was replacing a dimmer switch with a new three way switch in our dining room. I have all the neutrals wrapped together as well as all of the ground. Only thing I'm a bit unsure of is with only 3 places on the new switch and 4 wires how to go about making sure everything has power. When I took it the switch out the hot and and the light fixture were wrapped together under a nut and the other two were attached to the dimmer. Would i just need to do the same thing in order for the other switch on the other side of the wall to have power?
r/AskElectricians • u/Last_Baby_3998 • 7h ago
hi i just moved into my first apartment. I bought a $6 desk lamp from a thrift store because my bedroom overhead light makes everything look like a hospital waiting room. then last night I was doing homework with my wired headphones plugged into my laptop. I turned the lamp on and heard a faint buzz in both ears. lamp off, buzz gone. I spent a solid five minutes doing this before my roommate asked if I was trying to communicate with someone. here’s the weird part. the buzz is loudest when the lamp is dimmed halfway. at full brightness I can barely hear it and if I unplug my laptop charger and run on battery, the buzz disappears even with the lamp on. The lamp and charger are plugged into the same power strip.
does that sound like something a cheap lamp dimmer can do, or is the fact that it only happens while the laptop is charging a clue? I’m curious which part you’d check first
r/AskElectricians • u/Pilkman15 • 8h ago
Hey everyone, had my electric panel replaced a couple years ago because water was dripping from it. Of course, I just noticed that water is now dripping from this newer panel after no issues since being replaced. Since being installed we've renovated the basement but not around the panel itself so I can't imagine that caused an issue. How screwed am I? Was going to call the electrician that installed it tomorrow but is there any world where he didn't mess something up?
r/AskElectricians • u/No-Deer-5347 • 12h ago
I’m in Canada. When the roof structure is far from the t bar ceiling, how do you guys support to bx wire? ( armoured cable , AC90 , etc ) pictures would help
Thanks
r/AskElectricians • u/jph_otography • 8h ago
I recently acquired a huge photographic enlarger. I plan on using it for several different things. It looks like it was originally designed to plug into a transformer. (I attached a photo of the plug at the end) Unfortunately I think the chances of finding said controller might be slim.
The current setup: 4 - 24v 250watt halogen bulbs wired into indicator lights in the external shell that indicate all bulbs are functioning properly (this is a large piece of equipment and operating it in the dark it can be hard to tell if one of the bucks has gone out) there is also a large forced air external cooling apparatus that attaches to the enlarger and an outside window.
My ideal setup: utilize 4 halogen bulbs of the same diameter, between 2700k-3400k with an output of 1500-2000w. I would like to be able to wire this setup into the indicator light setup. I’m not sure if halogens are dimmable but if possible having a dimmer switch would be helpful.
I currently only have standard outlets in the room I am working in. That might possibly be able to change but I’m not sure.
Ideally all of this setup would be powered on and off by a standard household plug that could be plugged into a timer separately from the power source for the lamphousing. (most darkroom timers are standard household plug)
Alternatively:
I might be open to also just designing a transformer that can power the lights in place, and connect to a standard household plug to turn on and off the lamp housing. More powerful lighting would be helpful, but not required.
Most importantly I want this to be safe. And not terribly expensive. Unfortunately because of the color temperature requirements and the light quality requirements LEDs do not seem to be a viable option.
r/AskElectricians • u/Aaasteve • 8h ago
The wiring to my gas furnace currently runs from a 15 amp breaker in the breaker panel to an on-off switch then through a double outlet and then in to the furnace.
I saw the above video which showed running a 14 gauge electric cord pigtail from the furnace with the plug going into the receptacle when you have utility power and into the generator or battery during an outage.
2 questions: is plugging the furnace into the receptacle considered acceptable by code (Virginia if it matters)? I don’t want to have issues when the HVAC guys shows up for the annual service or when something breaks.
And 2, assuming #1 is legit, does plugging the furnace plug into a whole house transfer switch (actually a wing of the house and not the whole house itself, I want to power the furnace that isn’t in the area of the house covered by the transfer switch) that is powered by a battery avoid the floating/bonded neutral issue I’ve seen referenced ins number of videos?
I’d use the generator to periodically recharge the batteries, and not to directly power any circuits.
r/AskElectricians • u/Prestigious_bdupin • 9h ago
Bonjour
Nous avons un interrupteur qui grésille lorsque l'on éteint le luminaire.
Il gresillait il y a 6 mois lorsque nous avons mis un ventilateur plafond : nous l'avons donc changé par un interrupteur équivalent (Celiane)
OK pendant 6 mois et depuis ce jour, cela regresille.
Cela se produit quand on fait on=> off seulement et quand on va assez lentement.
Avez vous une idée svp ?
Merci
r/AskElectricians • u/Lazy_Design_3496 • 9h ago
r/AskElectricians • u/tallmon • 9h ago
Ignore the duct tape. This is a duplex. Original boxes. It looks like one has screw in fuses and the other as combo screw in fuses and some breakers. Can I replace all the screw in fuses with breakers ?
r/AskElectricians • u/Cool-Drink4642 • 10h ago
good evening all, and happy Thanksgiving!
I recently put up some Christmas lights, the usual deal with the little plastic clips to go on the edge of the gutters that you just pop the lights through.
and unfortunately I’m now realizing that I left the connections between the strips of lights, probably 3 or 4 of them, laying the gutters themselves.
so as rain has fallen recently, those connections are probably been getting wet. wether sitting in standing water or just getting wet, hard to say. but getting wet in some capacity for sure.
once it dries up, so probably later this weekend, I’ll go out and relocate them so they’re not just sitting inside the gutter where all that water would be standing or flowing, but I thought I’d ask here.
how’s my risk factor as it stands now? when I go back to it, should I disconnect the lights and check the male and female ends of the connectors for any kind of markings or signs of damage?
as dumb as I feel realizing this now, I’m sure I’m not the first home owner installing their Christmas lights to have made this mistake. at least, I’m telling myself that to help
me feel better / coping lol.
is the sensible thing to do just to hang the connections outside of the gutter or use the clips to put them on the edge as well so they won’t be so much risk of being in staining water that flows through the gutter during rains? let alone snow once that starts.
for now, I turned them off / killed power to them. thankfully I have a light switch on the inside that controls the exterior outlet they’re ran from, so it was easy enough.
thanks for any advance, and happy Thanksgiving again!
r/AskElectricians • u/pavelico • 10h ago
Hello. Trying to install transfer switch for EcoFlow battery for emergency use. 1st question: can I change that ground/neutral bar for longer one to free some space? Shouldn't be a problem, right? 2nd: upper left bracket is a double. Controls refrigerator and CFCI outlet on countertop. I want to connect transfer switch only to refrigerator. How do I do it. It's only 2 wires connected. AI gives me complicated explanations. Thank you for your time in advance.
r/AskElectricians • u/sad_little_bean16 • 10h ago
So instead of a stove, I have a sub panel. I wanted to keep my sub panel since it’s a 40amp sub, and I found someone on marketplace selling a load share and an EV charger for a pretty good deal, so I figured since I wanted to keep the sub panel, I would just hook up the load share to it. Initially it didn’t work, so I bypassed the relay from the NC contact (5) to the NO contact (2). I realize now that I was probably impatient, because once a couple minutes passed, the charger turned off. So then I swapped the wire from contact 2 to contact 5 because I figured something was happening and it took time for that to happen. Turned the breaker back on and now the charger works. So my question is, how does it work, and why does it take a while? I don’t see any capacitors, just a small transformer, an amp sensor, a fuse, the relay and the contactor.
The sub panel is only running some lights and the occasional table saw and various wood working tools during the summer.
r/AskElectricians • u/ZRE1990 • 10h ago
I have a couple of these recessed led can lights that I want to add a pendant fixture to instead. All the conversion kits I’m finding involve an E26 socket which this can does not have.
Do I need something specific here to make this work? Having a hard time tying to find a solution online. Unless I’m using the wrong terms.
Second photo is the install diagram for the pendant light I’d like to put in the leds place.