An electrician previously installed an outlet for a bidet seat attachment upstairs (unit has 1300W peak draw). I want to add a second bidet attachment to the basement bathroom downstairs and am weighing my options (splice vs adding new circuit)
The electrician ran 14 gauge wire to an old 15amp breaker that was no longer being used, so he repurposed it to be the new dedicated circuit for a 15amp gfci outlet for the upstairs bidet. Nothing else is on this circuit.
So, question is can I just add a junction box and tap into the existing 15amp circuit for the new outlet? 2600 watts would obviously trip the breaker if both bidets were being used at peak power at the exact same time (heating water up for 30 seconds), but idle draw is only about 100 watts for each unit, so having both plugged in while one is being used stays just shy of under 80% load.
It would have been nice if he ran a new 20amp circuit originally but it’s a 15amp since he probably assumed that there would only be that one bathroom outlet on a dedicated circuit (not sure if code allows for 2 behind-the-toilet bathroom outlets on same “dedicated” circuit for 2 seperate bathrooms so having 20 amp wouldn’t have mattered anyways?)
20 amp at 2600 watts would still go over 80% just a tad for both bidets operating at peak power, but likely would not trip the breaker since they only run at peak power for around 30 seconds to a minute or so.
Asking for advice from electricians. Can I just add a junction box and tap into that same 15amp circuit to supply power to the second bidet, or do I need to have an electrician add a new circuit?
I’m fairly comfortable doing wiring work (I don’t do any work directly on the panel and would always have an electrician do that), however I like to do my due diligence before deciding to do any work myself for safety’s sake (proper load management, staple placement, using the proper gauge wires depending on the circuit, etc).
The opposite side of the drywall is unfinished basement so the job would not be difficult for me to splice into the existing 15amp circuit via junction box to add a second gfci outlet.
Alternatively, I can run new 12 gauge wire right to the new outlet location and install the outlet myself and have an electrician hook up the other end to the panel for me. Or, the electrician could potentially run new 12 gauge wire upstairs and redo everything as a new 20amp circuit and have both bidets on the same 20amp circuit (if that’s even allowed).
Having both on the same 15amp circuit is easiest for me, and the likelihood of 2 people operating 2 bidets at peak power and tripping the circuit is fairly low. But, I recognize easy isn’t always correct.
As an electrician, what work would you recommend for this situation?