r/ElectricalHelp • • 15h ago

GFCI - High Temperature

0 Upvotes

I pointed my thermal gun at the GFCI in the washroom. It read about 36+ degrees Celsius(96 Fahrenheit). This seems high, there is nothing plugged in.

We replaced it with a new outlet, same thing, it runs hot.

The outlet feeds the washroom and then carries on to another outlet on another floor.

Is this normal? What’s the issue? The other outlets in my house are room temperature.

Looks like it one of the gfi loads feeds two spare bedrooms ceiling fans/lights, and the other feeds an outlet in the other washroom on the main floor….this is weird, right?


r/ElectricalHelp • • 17h ago

Lights flicker when washer is running

1 Upvotes

Hello!

As the title says, when the washer is running, my kitchen lights flicker.

- The flickering happens only during the agitation part of the cycle.

- You can hear/see that the flickering is in sync with the agitator moving back and forth

- The lights and washer are on different circuits, but they are on the same side of the breaker panel

- The laundry room is adjacent to the kitchen - the cables likely take the same path to the breaker panel (I haven't checked)

- We haven't noticed it with any other lights

- The light fixture probably uses LED bulbs (I'm not 100% sure if I've switched that one to LED yet, but I'm pretty sure I did. I can check, if it matters)

Any advice? It drives my wife nuts!

Thanks!


r/ElectricalHelp • • 23h ago

Help with wiring

Post image
2 Upvotes

Hello all. I have a light fixture in the basement that seems to have quite a few wires spliced into it, this was not how it was originally set up. I think somebody went in here. I’m not quite sure over the past couple years and decided to jerry rig a couple of circuits together. This one looks like it connects to the living room lights as well as a bedroom light upstairs, which should not be on the same circuit, but we’re here, so I’m trying to find advice as to how to connect this properly when screwed in the light bulb flickers as well as the other lights that are along the circuit and I’m not quite sure what was wired incorrectly


r/ElectricalHelp • • 21h ago

Voltage Regulator?

1 Upvotes

Having land issues hooking up my mother's trailer home and been waiting 10 yrs for a power line extension so I ran a 12 awg extension cable from my house (300 ft) to run her breaker panel. But the voltage drops down to about 90 volts when loads like the refrigerator kicks, which limits what she can turn on until the fridge kicks off. So I'm looking install a digital voltage regulator for her (like the Larson Electric 10kva single phase VR about $7K). Was wondering what the expert opinions are on this. I know that upsizing the cable to #2 or so might be acceptable but I'm not sure if this will bring the voltage drop up to an acceptable level. TIA all.


r/ElectricalHelp • • 1d ago

led light - to battery - to switch

1 Upvotes

good day, i have a question about wiring because i did something incorrect. what i have - pre wired 3mm led lights, pre wired AA and AAA batery packs with on / off switch and pre wired rocker switches. what im trying to do is add the external rocker switch to the lights and battey packs i installed over the years into minature Houses, art pieces and dioramas ive made. i made sure all the voltages were compatable i watched several tutorials on how to do the positive and negative set up. none said if i was supposed to leave the original switch in the on or off possision. what happened - they did work but the next time i went to turn it on two days later it had drained the batterys and didnt work. on the three i wired at the time. what did i do wrong? Please and Thank you.


r/ElectricalHelp • • 1d ago

[Aide / Recherche] Remplacement alimentation 29V sapin pré-illuminé (Balsam Hill / Fraser) – Équivalent possible

Thumbnail
gallery
1 Upvotes

Bonjour à tous,

Les guirlandes LED pré-installées sur mon sapin de Noël artificiel (un sapin Fraser de type Balsam Hill avec fonction scintillement doux) ne s'allument plus.
En inspectant l'installation, je soupçonne fortement un problème au niveau du bloc d'alimentation secteur :

Constat visuel : Il s'agit d'un bloc secteur doté d'une tête amovible/multi-pays (prise européenne / anglo-saxonne). Les broches métalliques rondes de la partie européenne qui s'emboîtent dans le bloc sont légèrement tachées et rugueuses au toucher, comme s'il y avait eu une surchauffe ou un arc électrique à cet endroit.

Ma question diagnostic : Est-ce plausible que le bloc soit HS à cause de ce mauvais contact/surchauffe, ou le problème peut-il venir d'ailleurs ?

Caractéristiques inscrites sur mon adaptateur d'origine :

Modèle : Switching Adapter CZH024290050TRWO
Entrée (Input) : 100-240 V ~ 50/60 Hz, 0.8 A max
Sortie (Output) : 29 V DC — 500 mA (soit 14,5 W)
Connecteur côté sapin : Prise cylindrique DC (a priori format 5,5 × 2,1 mm — voir photo jointe).

Ma recherche : Malgré de longues recherches avec la référence exacte, je n'arrive pas à trouver ce modèle précis — il est fort possible que je ne cherche pas avec les bons mots-clés.

Si vous avez quelque chose à me conseiller d'équivalent (même avec une tension ou un ampérage légèrement différent si cela reste compatible et sans risque pour faire fonctionner les guirlandes, comme un bloc 24 V, 30 V ou une alimentation universelle réglable), je suis preneur de vos recommandations ou d'un lien !

Merci d'avance pour votre aide !


r/ElectricalHelp • • 1d ago

LED Christmas lights troubleshooting

2 Upvotes

Intermittent flickering of some of the LED Christmas lights. As you can see in the video, even when the lights are out, they actually still glow faintly (most obvious with the greens but the other colors are very faintly glowing too). Does that help diagnose the problem?

The issue is intermittent, can fix itself for hours before recurring, so it’s unclear if reseating/replacing bulbs fixes anything. Would love to fix this definitively before assembling and decorating the tree. I have a voltmeter and a non-contact tester, happy to run tests.

Thank you in advance!


r/ElectricalHelp • • 2d ago

Use Load Center for a Splice Box

Post image
3 Upvotes

I want to gut this load center and use it for a splice box with a panel upgrade. The new panel will be set lower than the original panel to meet code so I need to splice the wires coming in from the top. Are there any issues with repurposing this as the junction box? Anything to watch out for that may ding my inspection with the repurposing?


r/ElectricalHelp • • 2d ago

Security Alarm Panel Battery Testing

1 Upvotes

Hello Electricians! I need a little help here. I’m trying to test my Battery Charging Current and the Draw from the batteries with the Alarm Panels AC power off. I have a Fluke 115 meter and it only shows in A and not mA. When I go to test, I get nothing but 0.00. My fuse is ok and should work. I should note it’s a brand new Multimeter. Even though the reading only shows A, I should still be able to see something. What am I doing wrong?


r/ElectricalHelp • • 2d ago

Advice for T5 low voltage landscape lighting

Thumbnail
gallery
1 Upvotes

I have a set of four 12v 4w pathway wedge bulb lights on a 16W transformer. They’ve all stopped working and the bulbs have blown so I believe it’s the bulbs. I took one of the lids off one to have a look and the bulb has disappeared. I don’t know if it’s melted or shattered causing the socket to become damaged. What are your thoughts and looking at the pictures, does the socket need to be replaced? If so, where can I find the replacements for the socket? I’m from the UK

Any thoughts?? Thank you :)


r/ElectricalHelp • • 2d ago

Question for the horde:

1 Upvotes

I installed a hot tub a couple of years ago outside my basement garage. I fed the disconnect panel from a sub panel breaker that has only 250v in the box and used the last breaker position for that wire.

My son asked if I could install a 250v outlet in the basement garage so we can run a smallish welder.

The sub panel breaker is a 90 amp & the hot tub sub-panel has a 50amp breaker.

Are there 250v receptacles that have an in/ out type plug like 125v outlets? I was going to install new 6awg to a 250v receptacle and then out to the hot tub sub-panel from the receptacle.

What is the correct way to do that?

And go easy on me, it’s my first question in here……


r/ElectricalHelp • • 4d ago

How to connect outdoor Christmas lights?

1 Upvotes

I have some Menards non-polarized lights with two prongs. I cannot find any extension cords for 50 ft to connect them. I purchased some from Ace, but they are all polarized or grounded. Is there a safe way to connect them or some kind of adapter?


r/ElectricalHelp • • 4d ago

Getting tiny electric shocks whenever I touch metal after using a sandwich press. Should I be concerned?

1 Upvotes

Hi everyone,

Something strange happened today and I’m trying to understand what’s going on.
I was making a potato using an electric sandwich press. I had boiled the potato, placed it inside, and closed the press while it was plugged in.
After 10 mins, I started experiencing very tiny electric shocks simultaneously whenever my fingertip touched metal objects.
It happened three times. Once when touching my fridge handle, Once when touching the tap, Once when touching my bedroom door.
The shocks were extremely mild, almost like tiny static electricity zaps. They didn’t hurt, and I haven’t noticed any burns or other physical symptoms.
It’s been around 20 minutes since I stopped using the sandwich press.
Could this be static electricity, or could the sandwich press have an electrical grounding or leakage problem?
Has anyone experienced something similar? Why is there electricity inside my body?


r/ElectricalHelp • • 4d ago

Short wires, is this okay?

Post image
1 Upvotes

Just added a 2 function switch/2 gang box, the original switch’s wires are old 12/2 no ground and a separate insulated ground wire, barely enough length to connect. I pigtailed the hot and ground to go to both switches and added 14/3 for the new switch. I plan on completely replacing the old 12/2 but it will take some attic work, will this work for now? Thanks


r/ElectricalHelp • • 4d ago

Help with custom chandelier

Thumbnail
gallery
2 Upvotes

The most electrical work ive done is switching out a new light switch box, but decided i was going to make a custom chandelier for my house. Its 5 lights in, one cord out (of the same material/wiring as the lights). Whites all together and blacks all together. Just want a second opinion on if this is safe, and or okay to do this way? If not any suggestions? Dont want to spark a fire and electrical things make me nervous. Bulbs will be led 120v, 60w.


r/ElectricalHelp • • 4d ago

Cooktop + oven on one circuit, 6mm² TPS, 32A main in a small cabin

Thumbnail
gallery
0 Upvotes

I'm building a small cabin in North Queensland and have an oven and cooktop to join and then out to the switchboard

Appliances:

Devanti induction cooktop, model CT-IN-C-YL-ID3501: 220-240V, 3000-3800W, double-square (Class II) symbol on the label

Sölt 60cm built-in oven, model GGSO605MS: 2.1kW. Has a wall mounted lead will need to cut.

Existing wiring

One cable from the wall to the switchboard, printed "Prysmian 450/750V V-90/3V-90, 2C x 6mm² + E 2.5mm² Cu"

Cores are red, black and green

Switchboard

The main breaker is a Hager MSN132, which I believe is a 1-pole 32A C-curve MCB. I have a second identical 32a breaker for the oven and cooktop

My rough numbers

Cooktop at full power: about 15.8A. Oven: about 8.8A. Together: about 24.6A

My plan:

Hager 32a breaker for the board (photo)

A junction box for the joins. I have 500V/40A containing 4 X screw tee connectors marked "3x6mm / 4x2.5mm".

My questions for the sparkies here:

- Are the junction box and connectors sufficient?

- Is the 32A Hager right for this circuit on 6mm² TPS, given a 3.8kW cooktop and 2.1kW oven?

- My main is also 32A. Is a cabin with a 32A main realistically able to run induction and an oven plus everything else?

- The oven and wall wiring have three cables, the cooktop just two. Is this okay to all go through the same connectors? I.e. 3 in +/- (oven, cooktop, wall wires), 2 in earth (just oven and wall wires)

- Are the tee connectors in the 40A box acceptable if they carry their own rating and compliance marking? Does mixing 6mm² and thin appliance leads in one grub screw worry you?


r/ElectricalHelp • • 5d ago

Can I split my exhaust fan/light into two separate switches?

Thumbnail
gallery
7 Upvotes

Hi, last year I had an electrician install an exhaust fan with light for my bathroom. There's only one switch that turns both the light and fan on. Without having to go into my attic and get real complicated, anyone know if I'm able to just replace the light switch? Right now it's a light switch/outlet combo. The fan is a Broan model HD80L-D. Some pics for context. Thanks for any help!!


r/ElectricalHelp • • 6d ago

I really need help with this

2 Upvotes

Alright so like 30 minutes my lamp was flickering then I turned a fan on and it dims the lamp then it shuts off then this repeats for a bit then I try turn the air conditioning on won't turn on it's just that outlet and it's in a shed I checked the breaker turned it on and off didn't fix it and im sorry if its not a good breakdown I don't know anything about electricity


r/ElectricalHelp • • 6d ago

Sauna Power Requirements

1 Upvotes

Planning for an outdoor sauna installation, the manufacturer states the following:

240V / 50-amp dedicated circuit, hardwired, 2-pole 50A breaker
3-wire: 2 × 6 AWG copper hots + 6 AWG ground. No neutral.

The NEC code minimum for a 50A OCPD and EGC circuit (Table 250.122) calls for a #10 AWG copper conductor.

I am wondering why the manufacturer requires the heavier #6 ground wire, and what is the risk of going with the #10?


r/ElectricalHelp • • 7d ago

How to fix 8 function Lights

Thumbnail
gallery
0 Upvotes

Hey there…

So I have a couple boxes of these enchanted forest 8 count 8-function candy cane lights .

However, two of the lights will not work that are halfway into the strand. I really don’t want to throw them away, so I was hoping someone with electrical knowledge could help me figure out how to fix them, if it’s possible.

I don’t know if it’s a wiring issue or an issue in the box.

Here are photos of them and their “function” box.


r/ElectricalHelp • • 10d ago

Timer delay relay and bypass wirinu

Post image
1 Upvotes

Im planning to make dc motor controller using timer delay relay.

The plan is using 1 switch as trigger for relay and 1 bypass switch to power the device directly without passing the relay.

Is configuration above correct?

Apologize in advance for bad english

the title post supposed to be bypass wiring not wirinu


r/ElectricalHelp • • 10d ago

I want to mount a front porch light fixture onto the brick wall

1 Upvotes

I have a house with the wiring for a front porch light beside the front door but no junction box and no light fixture. Just capped live wires.
It seems that most light fixtures require a *recessed* junction box but I don’t want to carve into the old brick to recess one.
I don’t mind drilling a couple of holes for screws to attach a junction box but that’s as far as I want to go.
Are there fixtures that can be mounted on a box that’s not recessed? Basically flat onto the brick wall? A lot of fixtures that claim to be “flush mounted” seem to require mounting on brackets that in the end leave a quarter-inch gap between the brick and the fixture.
I need help in finding them, if so — search terms on Home Depot and the like.
Thanks.


r/ElectricalHelp • • 11d ago

Residential Legacy Panel Height

1 Upvotes

Code has the highest breaker on a residential panel to be no more than 79" above the floor or platform. I have a legacy panel from the 60s with a top breaker at 89". The main feed conduit comes in from the side, and my new panel is larger than the current panel, so if I line things up with the main's conduit, I end up at 96" above the floor to the top breaker. Moving the conduit is going to trigger new holes in the wall to the meter etc.

Apart from filing for a variance, would it be reasonable to build a small stage below the panel to meet the 79" requirement, and if so, what are the expected stage dimensions to comply? Would a small step be adequate?

Any other ideas?


r/ElectricalHelp • • 12d ago

Adding fan/light to crowded circuit

Thumbnail
gallery
2 Upvotes

Recently bought a 1950's home with a panel from the 90's, lots of this black romex with no ground.  Ultimately would like to get everything up to code with new 14/3 & 12/2 and add a fan/light with its switch next to the current switch for #4 in the labeled picture. I have a 2-gang box to do that. Everything meets at a junction box which is also a light fixture, the hot wires have some melted insulation. Not sure how long it has been that way. The random ground wire comes from the kitchen circuit I think. 

Apart from being a crowded junction, this circuit powers 3 different rooms. Looking for advice on how to organize all this, if I should re-route things to different circuits, add a junction box, and if I need to open up drywall when adding new wires in any case. Grateful for any tips at all. Thanks!