This is just a theatrical question, if someone purchased a plug-in solar battery and just connected it via a 3-pin socket as in legal in most European countries, would it just work? Assuming the danger level is low considering its approved in a lot of other countries.
Hi , I've seen a video about a new regulations for home battery apparently it will be super strict. I recently had the 5kw battery installed before the new regulations but was thinking of up sizing . It was installed in the cellar. Does that mean I need to move the battery somewhere else?
I’ve got a Fox ESS battery system with 35kWh of storage, installed on the side of the house. With temperatures dropping recently, I’ve noticed a significant reduction in charging performance overnight, despite having Forced Charge scheduled.
Outside temperature: 0°C Battery cell temperature: 3.8°C Actual charging power: Just 1.8 kW, despite a 10.5 kW setting. Overnight charging window: 23:00–06:00.
Battery only reached 65% SOC by the end of the charging window yesterday.
The frustrating part is that I’ve got plenty of 7p electricity available overnight, but the battery isn’t getting anywhere near full before the morning.
Is that level of charging limitations normal/what others are seeing in temperatures fall below 5°C?
I'm looking into solar. From posts I've seen here my understanding is that going for maximum panels is what is recommended if you can.
I'm fortunate to have a decently sized roof that can fit upwards of 40 panels on it. It's East/West facing with a slight south east facing angle (front of house is West facing about 80° from North, back of house is East facing about 100° from North). There's no shading. (See attached image).
I'm located in South West Scotland. I have an EV but aware that shouldn't care about or see the system. Can't give an accurate annual consumption as have only just moved into a house from a small 2 bed flat in London.
My naive plan was the following but very open to any tweaking that is recommended:
Get 40+ panels
15-20Kwh+ battery (daily usage is currently around 12-15kwh as we have partial AC heating), heat pump doesn't seem viable currently without a lot of work.
Inverter size large enough to handle exporting as much as possible, 8-12kw?
Gateway for impending apocalypse
Charge battery overnight on off peak rates, run off battery during day, export all solar at higher export rate, arbitrage the sun
What's confusing me is the installers I've spoken to, don't really seem convinced this is a good idea. Some haven't even heard of it. One even said that many solar panels wouldn't work with a 12kw inverter as it would generate at peak upwards of 20kw and they'd have to install 2 inverters.
My understanding is that it's unlikely to generate that much at peak due to different direction facing roofs, and that clipping is worth it for increased generation in winter where I won't even get close. But could it be that too much solar generation would actually not be compatible with such a system?
I've had a range of systems quoted to me:
Fox
Sunsync (installer says they can't do gateway with this)
Ecoflow Ocean 2 (most common)
Tesla
All around £20,000-£24,000, which seems a little high and it could be improved on potentially?
Is my understanding correct? Am I going about this incorrectly? I've just not had any confidence from any installer I've spoken to yet about what is the best solution for me, they all just seem like they want to sell a much smaller system to me.
Installers contacted:
Contact Solar (EDF, little spenny, can only do Tesla or Sunsyc and only Tesla with gateway)
Flo renewables
MCNL (Said I should be self consuming solar instead of prioritising exporting :/)
Solar and battery newbie. I’m rocking a Duracell battery set up with 16kWh battery.
I’m set up to export excess energy back to the grid.
Do people force discharge their battery late in the evening, and then top the battery up during cheap night time rate?
I googled this and the google said this is a bad idea as it degrades the battery and isn’t worth the small financial benefit.. 13p to sell it back and 6.6p to buy it back.
What do you think?
Edit: my tariff is a basic EV tariff with EDF.
25p day time. 6.6p night. Seperate SEG tariff 13p export.
I am planning on getting a heat pump and as such am looking at upgrading my battery and inverter. Currently I have a 3.68kw inverter and 9.4kwh battery (Hanchu). I think I'll need around 20kwh storage to cover most days and 32kwh to cover pretty much all but the coldest days. I'm also looking at pricing in a backup gateway too. If I stick with Hanchu I have the following options based on some quotes (North West region) I've had already:
Keep the inverter, get 2 additional 9.4kwh batteries (28kwh total) and a backup gateway: £4930
Add a 6kw Hanchu inverter for £1300 (inc installation, G99 paperwork and MCS certificate) (total £6230). Weird thing is looking at the specs is that the 6kw Hanchu can only discharge 5kw from batteries, so it may as well be a 5kw inverter.
Add a 8kw Hanchu inverter for £1820 (total £6750). (Advantage of this is there's a 3rd MPPT so we could potentially DIY some panels on our single storey kitchen roof and have them on an independent string so they don't drag the others down).
Replace the 9.4kwh battery with a pair of 16kwh Hanchu batteries. This would be £6230 with a gateway (but no inverter, inverters still as above, so £7530 with the 6kw or £8050 with the 8kw). But we'd now have a 9.4kwh battery to sell and 32kwh of storage.
I guess if we're taking out both the existing battery and inverter it opens up the possibility of any other brand of battery and inverter, so does sticking with Hanchu make sense based on these quotes or are there others that would make more sense? Also, would a 9.4kwh Hanchu battery and 3.68kw inverter have any resale value? I know Hanchu kit is a bit locked down to registered installers so I'm not sure whether it would be hard to sell on. But if we can sell it, then I can take that into account with those quotes too.