r/ukheatpumps • • 10h ago

Help/Advice My lounge is freezing

Post image
14 Upvotes

My Grant heatpump was installed in July, and I had long conversations with the engineer who did the design about my lounge being always cold (I don't need aircon!) and chose to upgrade the borderline radiators to larger ones. My house is 1970s, concrete floors, filled cavity walls, loft insulated, central heating retrofitted and therefore taking a convoluted path around the house. The lounge has two huge windows/patio door installed in the 1990s. The lounge and bedroom face north, (converted) garage and office face south. The lounge was cold last winter too so I added thermal blinds but I'm considering replacing the windows (heat loss per survey = 476W, current u-value estimated at 2.8 and my calculations measuring temperatures confirm this). Is this likely to make a significant difference?

The design flow was 50° I have my thermostat at 21.2°, setback at 19.5°, hysteresis at 1.0°. Today's "calculated set temperature" is 46.6°. I think this Is the weather compensated flow temperature - is that right? I've increased my heating curve to 1.3 now the weather is cold. Most of the house is comfortable, and the garage is too warm, so I got up early this morning to see which radiators warmed up first prior to balancing them. I was planning to balance down the south facing rooms - is that the right thing to do? I wasn't expecting to need to be a heating engineer, but I think I need to learn. Where can I find resources to help someone with only a 1970's physics A'level to understand? P.S. I tried asking ChatGPT, but it goes off on long rambling explanations and tells me not to spend any money on double glazing.


r/ukheatpumps • • 4h ago

8mm micro bore radiator pipes

2 Upvotes

Hi all, looking forward to when my gas boiler will need replacing, in an ideal world I would like to move to a heat pump, however many of my radiators are connected with 8mm micro bore pipes.
Many plumbers I have been talking to, have told me that a heat pump would not work for me unless I replace all of the pipes.
Is this strictly true? What options do I have?


r/ukheatpumps • • 5h ago

Can you help me with this?

Thumbnail gallery
1 Upvotes

r/ukheatpumps • • 21h ago

Should I consider a heat pump? Currently have an Electric Boiler…

17 Upvotes

We’re using 50–85 kWh of electricity per day in winter - is this normal?

We’re trying to get to the bottom of our extremely high electricity consumption and would really appreciate hearing from anyone with a similar electric central heating and hot-water setup.

We live in a three-bedroom detached house in Essex, built in the 1960s. There’s no mains gas available, so all our heating and hot water are electric.

Our property:

  • Three-bedroom detached house, occupied by two adults.
  • Cavity walls insulated approximately 15 years ago.
  • Loft insulation approximately 300mm (2025)
  • Triple glazing throughout (2025)
  • Radiators replaced approximately two years ago as part of a full house refurb when the electric boiler was installed.

Our heating system:

  • EHC Fusion Comet V2 electric boiler (14.4kW).
  • EHC Neptune 180-litre hot-water cylinder.
  • Central heating typically switched on manually for around 4 hours during colder evenings.
  • Hot water programmed for 6am–8am daily and sometimes 6pm–8pm on weekends, throughout the year.
  • Separate immersion heater switched off.
  • Central heating isn’t used during summer and early autumn. We started using it again around mid-October.

Our electricity consumption:
We’ve been investigating our usage because our electricity bills seem exceptionally high.

Some actual figures from our smart meter:

  • 29 June–13 July: averaged 20.6 kWh per day, without central heating.
  • 13 July–3 November: averaged 26.6 kWh per day, although heating started being used in mid-October.
  • 10 November: 60.75 kWh.
  • 11 November: 53.99 kWh.
  • 12 November: 71.92 kWh.
  • 13 November: 72.46 kWh.
  • 14 November: 86.27 kWh.
  • 18 November: 58.37 kWh.

Our electricity tariff is approximately 26.61p/kWh, plus a daily standing charge of 50.55p.

Some days we’re spending £15–£23 on electricity alone, which is becoming increasingly expensive.

What we’ve investigated so far:
We’ve tested our household appliances individually using the smart meter.
With virtually everything switched off apart from refrigeration and our internet router, consumption drops to around 39–40W.

Even with several rooms of LED lighting, two televisions and a gaming laptop charging, consumption is generally around 575W, with occasional increases when appliances cycle on.

This makes us suspect that the electric boiler is responsible for the majority of our winter electricity consumption.

We’re currently carrying out tests with the central heating completely switched off while keeping the normal hot-water schedule running, to see how much electricity we’re saving. But still spending approx £7-£8 per day.

What we’d really like to know:

  1. Does anyone else have an EHC Fusion Comet electric boiler, or a similar direct-electric boiler supplying radiators?
  2. What sort of daily electricity consumption do you experience during winter?
  3. How many hours per day do you run your central heating, and what does it cost?
  4. How much electricity does your hot-water cylinder use? Is our twice-daily programme reasonable?
  5. Has anyone switched from an electric boiler to an air-source heat pump? If so, how much did your electricity consumption actually decrease?
  6. Are there any settings or changes you’ve made that have significantly reduced electricity usage?

We’re now seriously considering replacing our electric boiler with an air-source heat pump, particularly given the Boiler Upgrade Scheme grant.

I’d be especially interested in hearing from people who have made this conversion and can share genuine before-and-after electricity figures rather than theoretical savings.

Are our electricity figures typical for an electric boiler, or does something seem excessive?

Any experiences or advice would be greatly appreciated. Thanks!


r/ukheatpumps • • 11h ago

Heat pump noise: what if it complies with MCS permitted development, but neighbours complain it's too noisy in their garden?

Thumbnail reddit.com
2 Upvotes

EDIT: to clarify, the focus is on reversible heat pumps used for cooling in the summer (air conditioning), since neighbours are unlikely to use their gardens much in the coldest winter snaps.

I am familiar with the rules on permitted development and the related MCS noise calculations, but those assess noise at the neighbours' windows.

My questions are:

  • what are the rules for noise in neighbours' gardens? They are not directly covered by the MCS rules
  • There can be cases where the noise at the windows <= 37 dB (the MCS requirement) but the noise in the neighbours' garden > 37 dB. What then?
  • I imagine councils won't intervene if the noise is 38 dB but will intervene if it is 70 dB. But are there rules, guidance, laws, legal precedents? Can each council set its own rules? Can one council have a policy not to intervene below 45 dB and another one not to intervene below 40 dB?
  • Can one council require a maximum level of noise, and another one require it to be within certain limits of the normal background noise? Decibels are logarithmic, so if the background noise is 40 dB and it becomes 45 dB when you turn on an appliance, the appliance alone produces 43.3 dB
  • If my heat pump fully complies with permitted development and I have all the paperwork to prove it, but neighbours wanted to complain about noise in the garden, who would do what? Would they call the council, and the council would come and assess noise? Do they have to buy a decibel meter, record noise, and present that to the council? I doubt the council would immediately install 24-hour professional sound monitoring equipment?
  • How are times of day assessed? That's not an excuse for MCS calculation, but for garden noise? If the pump is louder, say, during cold snaps, when neighbours are not having dinner al fresco in their garden, is that a defence?

EDIT 2: I do not understand why people are getting so worked up. Noisy condensers exist. Big houses with multiple rooms need bigger condensers. Eg the Mitsubishi Electric MXZ-6F122VF has a sound power level of 69 dB https://library.mitsubishielectric.co.uk/pdf/book/MXZ-F_R32_PI_Sheet#page-1-2
Condensers from other brands have similar noise levels


r/ukheatpumps • • 21h ago

What hysteresis setting are people using for heating?

5 Upvotes

Struggling to find much about hysteresis settings on central heating. Online the best suggestions I've found are about 0.3 degrees C, but want to see what other people are saying.

Originally ours was about 1 degree C but that felt like the house was dropping by too much and then taking ages to get back up.


r/ukheatpumps • • 19h ago

Help/Advice Best place to buy/source an a2a heat pumps

3 Upvotes

Looking to find a local air con expert to install it but source a Mitsubishi electric/ Daikin ( rather than using a third party like heatable and get bamboozled by crazy price of labour)

I assume this approach would be cheaper given I'm thinking to buy 3/4 indoor units?

In anticipation of potential BF sales. Are there any websites or approaches to sourcing the a2a units that you recommend?


r/ukheatpumps • • 5h ago

Help/Advice Neighbour’s heat pump very noisy

0 Upvotes

My neighbour’s heat pump is very noisy and I can hear it in my garden. Is this normal? It was installed less than a year ago and it made this much noise the entire time. What is likely to be causing it to make so much noise?

I was going to ask them to get it fixed but I thought I’d check that it’s not normal first. If I could point them in the right direction for making it less noisy that would be helpful too.

Thanks


r/ukheatpumps • • 1d ago

Cheapest way to run a heat pump

13 Upvotes

Getting a heat pump installed early next year (currently have an oil boiler.) My tariff is with EDF and we pay 22.54p kWh. Standard tariff and fixed until March ‘28. With prices due to soar in Jan, it would make sense to stick with this tariff for the foreseeable. W have no solar or batteries. With this in mind, what’s the cheapest way to run a heat pump? I read it’s best to set it to a temperature and then leave it. If so, what temperature? What about hot water? We currently have the oil boiler come on for an hour a day to heat our water. I see lots about heat curves but how do they work and how do you set it for your house?


r/ukheatpumps • • 1d ago

A2A hybrid usage with gas system

Thumbnail
gallery
3 Upvotes

Hello Everyone,

I wanted to check how everyone is doing with their heating system during the November period and wanted to compare.

Mid terrace property in Essex, I do have gas boiler system heating of DHW tank, 10 rads and 1 underfloor system using tado.

I do have 5 A2A units working at various times to heat house at offpeak times to pre heat house, and certain rooms being used bit higher then the limit of the tado during the day.

I do have solar and storage, ev charging via granny. From December my gas price will double to 9.4p and my electricity will be at 6.66p offpeak and so will shift DHW to heat by electricity.

Send how you are doing, if you have a similar system and how you improved? I tried to heat house just by the A2A system but wife kept on complaining so I do my hybrid usage.


r/ukheatpumps • • 1d ago

New build install under BUS grant, friendly installers?

5 Upvotes

Hi all

I'm eligible for the new build BUS grant and but struggling to take advantage of it!

The install should be about as simple as it gets. No existing equipment to remove. There is a utility room with plenty of space. Walls will be open, the primary pipework will already be run, underfloor pipework already in place, high voltage electrics in place etc. We've already done heat loss calcs as part of the build.

I've got a few quotes from grant-eligible MCS installers and they have come back really high. I would probably be better off not claiming the grant, then buying the equipment myself and having my plumber hook things up... which seems silly. I can buy the equipment for about £5-7k (ashp, cylinder, controller and accessories). I'm getting quotes for £15-17k (before grant).

Cool Energy have a very appealing offering (£0 after grant for self install), but they don't have a unit in the 7-8kW range.

Does anyone know of any friendly installers who might be worth reaching out to? (London/Herts area)


r/ukheatpumps • • 1d ago

Installer wired up wrong?

Thumbnail
gallery
3 Upvotes

We had solar installed first and then last week the heat pump. The heat pump installer has branched off from the incoming utility supply before the fox ESS install. As a result my Fox system isn't seeing the demand and so the battery storage isn't contributing to the heat pump demand.

How should this have been done? I'm calling them back in to fix it. Frustrated as I'm paying full import rates until it's resolved.


r/ukheatpumps • • 1d ago

Doest Grant HP with Econet contnue running even after set point is reached ?

Post image
2 Upvotes

Hadnt noticed before, but today, the HP has decided to continue even after the set point is reached...I dont think this used to be behaviour before.

I asked Claude, and it suggested it could be the controller heats to setpoint+hysteresis, but, I would have noticed that before.

It then said maybe under some conditions the controller ignores set point and follows weather compensation...sounds made up to me.

Maybe there is some setting buried somewhere that does it, anyone know?


r/ukheatpumps • • 23h ago

Ground source heat pump not working

Thumbnail reddit.com
1 Upvotes

r/ukheatpumps • • 1d ago

Ecodan ASHP self-learning weather curve controller

Thumbnail gallery
2 Upvotes

r/ukheatpumps • • 1d ago

Please pleas help

Thumbnail gallery
3 Upvotes

r/ukheatpumps • • 1d ago

Help/Advice Is a2a better than a2w and ground source for heating, when some rooms/floors remain empty for long periods?

3 Upvotes

This is just curiosity - I think I will be installing a2a because I also need cooling.

If we think of air to water or ground source heat pumps, I understand they are the most efficient when you leave the whole house at a constant temperature for most of the day.

However, is there a point where being forced to keep the heating on most of the time becomes more expensive than an alternative system (eg a2a) that you can more easily switch on and off room by room, hour by hour? Can gas boilers + radiators ever have lower running costs in these scenarios?

For example:

  • house extended into the loft. The loft always gets colder. Can a2w or ground source systems keep the same temperature in the loft and in the ground floor, even if it means the loft needs more heating? Or would heat pumps not work well here because the loft is not insulated enough?
  • Spare room in the loft. Used only for guests. What's the best way to avoid heating a room which rarely gets used?
  • House empty between 8am and 4pm. Should you keep heating it anyway? The kids arrive at 4 but tend to stay on the ground floor and to only go on their rooms on the first floor after dinner. Is it easy/efficient to program it so that the first floor gets heated later? Is this easier with radiators and smart valves than with underfloor heating?
  • What if instead a child goes to their room earlier than usual and needs to boost the heat? Is it that underfloor heating is slow but smart thermostat valves on radiators can give a quick boost?

r/ukheatpumps • • 2d ago

Post Your Setup Is a heat pump/battery financially worth it?.. An answer rather than a question.

54 Upvotes

Thought I would throw this in here as it's always asked. I don't have masses of data but I feel I have enough to see the direction of travel.

I wanted to compare like for like as best as I could - months of usage and cost for previous gas months vs. the same for heat pump the following year. Down below is what the heat pump has done for my energy bills.

My heat loss was quoted at 7.62kw and it's come out ever so slightly over. I have a 7kw Arotherm Plus but crucially I went for 32kw of battery storage and switched to an off peak tariff but I've modelled both. I have a house load around 14kw daily before heating.

Here are my findings so far. This includes regular house usage, 21.21p for elec, 6.5p for gas.

Just the heat pump:

  • August 25 vs 26 - £131 vs £96.63. 26% cheaper
  • September 25 vs 26 - £162 vs. £113.11. 30% cheaper
  • October 25 vs 26 - £248.67 vs £155.94. 37% cheaper
  • November 25 vs 26 - £310.54 vs £211 (projected). 32% cheaper

Crucially though I did the battery so my savings are different. Here is how it looks for us with Heat Pump and Battery storage, this is just elec at 35p or so peak and 6.66p off peak, it also accounts for the round trip losses as this is grid/bill data:

  • August 25 vs 26 - £131 vs £51.61. 60% cheaper
  • September 25 vs 26 - £162 vs. £55.25. 66% cheaper
  • October 25 vs 26 - £248.67 vs £73.80. 70% cheaper
  • November 25 vs 26 - £310.54 vs £81 (projected). 74% cheaper

I only ever planned to get the heat pump as a means to be able to shift energy usage to off peak and later to solar. I am finishing each day right now with somewhere between 10% and 20% left on the battery which means I will likely only use peak grid energy in January or on some exceptionally cold days (we have had one here so far although I hadn't optimised my usage so could likely have avoided it).

The all-in setup was £6k for the heat pump after BUS, £6.4k for the batteries and £2k back from Halifax for a £10.5k outlay.

Is the heat pump worth it financially on its own? For me, no. I might knock £500 or £600 off my bills annually but compared to the £4k outlay on just the heat pump, the payback period at 7 years was too long and there's too many unknowns over such a timeframe.

Is a heat pump worth it financially with a battery? Of course, I will recover over £2.5k annually at todays rates and remove the energy price worry from my life indefinitely. My payback period becomes 4 years and I retain a little certainty I will be shielded from energy prices.

Is it better than gas heating? Definitely yes! This cost saving is coming while my house sits at a constant 21c and I have never reduced it. I had some very complex timers and automations via home assistant when on the gas which would fluctuate the target temperature based on time of day, who was in, and so on.. and for what?.. to still be paying through the nose and have the house cold half the time. All I have on the heat pump is a ramping of the curve in the off peak period to do a little more of the work in the off peak window. If comfort is your thing then my experience is that it is cheaper and it is more comfortable.

Insulation and radiator sizing were key though for me. I know some people say it's not but that's not my experience. You will need to bump up the power to heat your coldest room to a hotter temperature and throttle your warmest rooms a lot to balance it.

..and in charts. Aug, Sep, Oct are the first and last 3 bars of each chart, for 2025 and 2026. Nov 25 is in there but not 26, we have done no more than £3 a day so far in Nov.


r/ukheatpumps • • 1d ago

Help/Advice Isolator on manifold for UFH

Thumbnail gallery
1 Upvotes

Should this isolator switch be on or off in normal use?


r/ukheatpumps • • 1d ago

Octopus Cosy Pods - Noise?

1 Upvotes

I hope this isn't too random a question!

Please can someone with Cosy Pods tell me if they make a clicking sound when turning on or off. I might have to have one in my bedroom and was hoping to avoid the clicking noise my Tado thermostat makes!

I'm hoping it's purely semiconductor control without a relay or reed switch.


r/ukheatpumps • • 2d ago

Help/Advice Wake up to a sad heat pump

Post image
9 Upvotes

Great to wake up thinking the heat pump is ticking along nicely as the load on the house was low, given the temperature outside (-2°).

Not good to then realise that actually the heat pump has decided to give up.

Several power cycling restarts later, no luck. Vaillant can only come out in 5 days - I’m only 5 miles down the road from HQ.

Has anyone else experienced any F.9998 issues with the new aroTHERM plus 12kW heat pumps?

Gutting thing is I’m only 3 weeks into my installation - still within a 30 day statutory faulty goods period!


r/ukheatpumps • • 2d ago

Heatpump running cost 😂😂

Post image
8 Upvotes

r/ukheatpumps • • 1d ago

Radiator types. Specifically type 21 single fin double panel.

3 Upvotes

Thinking about switching to a heat pump and I'm aware type 22 (K2) would be best to handle lower flow temps.

I have 23 rads in my house of which.

x5 of type 22 -(k2)
x5 of type 21 -(P+)
x3 towel rads.
x10 of type 11 -(k1)

I know the type 11 need to be swapped out, but is it necessary to change the type 21 rads?

how many of you are running with type 21 single fin double panel without issue?

house is 237sqm built 2016.

Thanks


r/ukheatpumps • • 2d ago

Help/Advice How many kWh are you using vs prior use?

5 Upvotes

As in the title. How many kWh are you using now vs spending on gas previously?


r/ukheatpumps • • 2d ago

Help/Advice Firmware for Aerona R32 smart controllers

2 Upvotes

Anyone have access to the firmware required for the smart controllers to work with the Aerona R32 rather than the 290? Read online that you can manually update. Would be great if someone could provide me a link to download.

Bought a smart controller to replace the LCD model but the firmware is wrong even though the back of it states Aerona! 🙃

Also emailed Grant directly but they may tell me to bugger off!