r/askanelectrician • • 2h ago

Breaker blew and this happened. How bad do you think it is. I’m renting

Post image
3 Upvotes

r/askanelectrician • • 55m ago

Getting High Voltage Occasionally ~260v+, need advice to overcome it

Thumbnail reddit.com
1 Upvotes

r/askanelectrician • • 8h ago

Replacing Appliance Cords

3 Upvotes

Hi! We have two appliances with 6 foot power cables, which are a few feet too short for where our outlets are located. I'm looking into replacing the power cables entirely instead of plugging these appliances into an extension cord. We rent, so we can't change outlet placement or anything like that.

One is an electric heater: 120 VAC, 60 hz, 12.5 amps, 1500 watts. The other is a TV. I haven't been able to find electrical information for it.

Is this something I could safely do myself with no electrical experience? Or something to hire an electrician for? I know heaters can be a fire hazard so I want to minimize risk there.

Are there any risks in replacing power cables with longer ones?

Anything else that I'm missing?


r/askanelectrician • • 4h ago

Need help with power problems

Thumbnail reddit.com
1 Upvotes

r/askanelectrician • • 10h ago

Blank GFCI? Replace with Gfci with plugs or no?

Post image
2 Upvotes

I’m wondering if I can replace this to have more plugs available in my garage. This outlet is located about 4ft from 1 Gfci outlet with plugs in my garage.


r/askanelectrician • • 7h ago

Why won’t two of my lights on this switch work?

Thumbnail
gallery
0 Upvotes

This light switch is by my front door. The first two switches work fine.

The third switch I’m assuming connects to the porch light, which is an LED driver, but it doesn’t work (second photo).

The fourth switch I’m assuming connects to the spot light (third photo). I changed the bulb, but doesn’t work, and a voltage meter tells me it’s always hot.

What’s going on here?


r/askanelectrician • • 8h ago

very different quote amounts for new house

Post image
1 Upvotes

r/askanelectrician • • 8h ago

Re-Install Doorbell Transformer Cost

Thumbnail reddit.com
1 Upvotes

r/askanelectrician • • 13h ago

Subpanel Question

Thumbnail reddit.com
2 Upvotes

r/askanelectrician • • 13h ago

Switched ceiling fan light only lights when fan is on high

Thumbnail reddit.com
1 Upvotes

r/askanelectrician • • 14h ago

Improper pigtailing?

Post image
1 Upvotes

r/askanelectrician • • 18h ago

Wire gauge for a single item.

2 Upvotes

I’ve got a “rate of rise” hardwired heat detector that is specified for 14 ga wire. It’s going to be the last item on a circuit that’s 12 ga and has a run of only 2 feet.

Can I connect the 14 ga to the box with 12 ga or do I have to pigtail at the detector?

TIA


r/askanelectrician • • 16h ago

Advice on getting electric to my ceiling for a fan.

Thumbnail gallery
1 Upvotes

r/askanelectrician • • 16h ago

Installing a new stove

Thumbnail gallery
1 Upvotes

r/askanelectrician • • 16h ago

Lathe not working.

Thumbnail gallery
0 Upvotes

r/askanelectrician • • 18h ago

Heated floor issues

Thumbnail reddit.com
1 Upvotes

r/askanelectrician • • 18h ago

Is this lighting wiring suitable to use beneath outdoor stairs?

Thumbnail reddit.com
1 Upvotes

r/askanelectrician • • 14h ago

How to install Kitchen outlet (2Red,2Black,2White and 1Copper wire)

Thumbnail
gallery
0 Upvotes

Would need some help on how to install a simple outlet. I have this set of wires only in two outlets on my kitchen countertop.

I see 2 black, 2 red, 2 white and one bare copper wire. How do I install these on a regular outlet? Pics for reference. Thanks in advance


r/askanelectrician • • 19h ago

Undercabinet lighting circuit routing

Thumbnail
gallery
1 Upvotes

We're in the process of renovating our kitchen and our electrician has steered us toward line voltage undercabinet lighting (perhaps because we asked for dimmable, and they maybe dim better, not really sure). The electrician (he's an apprentice but has been pretty decent) has run romex from all the undercabinet lighting fixture locations to the basement, and asked that when the drywall went up, that we just leave them stubbed out through the drywall. I went around and marked that at 54" (bottom of upper cabs) for the drywaller, and that's what he did.

I'm curious what happens next. The stub outs are not quite at the beginning of the UC runs, but pretty close, but I'm curious how the hole in the wall gets hidden. I told the electrician we didn't want to see a hole in the drywall and is there a grommet or something or what do they usually do to finish this off. I think he had assumed there was a tile backsplash going in. There is not. Our conversation went down a different rabbit hole, and we didn't get back to how this actually gets finished.

It's a smaller operation. The project manager is very busy typically spending most of the day on site and visiting jobs to do quotes. The electrician isn't here right now, because there's nothing for him to do until we're ready for fixtures to go in. Interested to hear any other ways to finish this opening and how it usually gets done. I know my wife doesn't want to see a raw hole in the drywall as the entry.


r/askanelectrician • • 23h ago

3 phase contactor fried itself? Help!

Thumbnail reddit.com
1 Upvotes

r/askanelectrician • • 1d ago

1st EV Charger Install.

3 Upvotes

The guy that I asked electrical advice from for years is no longer around. He helped me do a lot of work on my own house from adding outlets to sub panels.

I already have a Hubble 14-50 outlet that's designed for EV charging and starting out to save some money I plan to just use the charger that comes with the car. But in the future I want to add a Tesla Wall Charger.

My run is about 100' +/- 10' or so. I'm going to install 1" Conduit (Not sure if I'm going to do PVC or EMT yet) through the crawl space under my house to my garage. Then use 3x #6 THHN and 1x #8 THHN (ground) and use a 60A breaker to meet the 125% overhead.

I have the option to go through the attic but I think the heat in the summer may push me to #4 which it's starting to get real expensive. The attic run is the easier run but to keep costs down I'm going the hard route.

Does this sound reasonable?


r/askanelectrician • • 1d ago

Found in closet in old apartment that has been renovated

Post image
1 Upvotes

r/askanelectrician • • 1d ago

Ceiling fan wiring, replacing light kit

Thumbnail
gallery
2 Upvotes

Question, lights stopped working on ceiling fan. Fan has always ran regardless of wall switch position and still working; wall switch only controls light. Idk if that’s on purpose from previous homeowner.

I understand the black wire is hot for fan, blue is hot for light. White are neutral and go together. I don’t understand why the blue goes into that connector that appears to be the fan direction switch. I did not undo existing wiring, but connected white to white and blue to black with wire nuts on new light kit.

Fan continues to work, but new light still not working. Husband said both bulbs popped and went out at the same time which is why we’re replacing the kit.

I’ve contacted a handyman but no response yet, so trying to figure it out.