r/ukheatpumps • • 4h ago

Journalist request: Have you saved money by installing solar panels or a heat pump?

1 Upvotes

Hello,

I’m a journalist working with The i Paper and I’m looking to speak to UK homeowners who have significantly reduced their energy bills by installing solar panels, heat pumps, home batteries or other green technology.

It would be great to hear about how much the installation cost, how much you’ve saved and whether you think it has been worth the investment.

We’re also looking to speak to people who might be comfortable providing some videos of themselves and their installations for our video team - you can see what I mean in the articles below.

Here's some examples of similar sorts of articles we've run in the past:

https://inews.co.uk/inews-lifestyle/money/reduced-energy-bills-zero-heat-pumps-solar-panels-4483601?srsltid=AYCX9vJTASnummwxrs1NpMtV0yH9jEU99nMWnQbg87mQFR4_aRJOdsku

https://inews.co.uk/news/ive-got-heat-pump-solar-panels-monthly-bills-4400032?srsltid=AYCX9vJEZwiEm7YgvH8OPIhwIlvIZJ6G_tEx-b3LK9y1mBmrNlulx9NG

If you’d be interested in sharing your experience, please comment below or send me a private message.

You can also contact me directly at justin.bond@theipaper.com

Thanks.


r/ukheatpumps • • 23h ago

ORA renewables (future heat and renewables?)

1 Upvotes

Hi everyone. I’ve had a quote from this company which is about 3 hours away but they came and did a survey and I’ve now received the quote which is very cheap compared to other companies I’ve had round.

This company is fitting an ebac heat pump as it’s through ebac so I should get the 12 year heat pump warranty.

My question is this company started Jan this year. Also not sure if used to be a diff company future heat and renewables and changed there name? Not sure what’s going on and if it’s something to avoid. Like I say the price seems cheap.

Has anyone used this company? I don’t trust the reviews it always has.

Thanks.


r/ukheatpumps • • 17h ago

Heat Pump Installation: British Gas

2 Upvotes

I’ve not seen any posts (that I remember) about installations by British Gas.

Has anyone got any experience they can share, please!


r/ukheatpumps • • 16h ago

Reducing flow temperature makes huge difference

46 Upvotes

I have a Grant 15.5 KW system installed 3 months ago. So last few days were first proper cold days using HP. I have a 32KWh Fogstar battery. I charged it overnight with cheap EV tariff (EDF) and hoped it can last the whole day in such weather. I didn't expect HP was so power demanding. I set the comfort temperature at 20.5c. At 9am, the battery only had 40% left yesterday. At 2pm, all juice was gone and I had to use peak tariff. The installer set the curve shift to +5. So the flow temperature is like 48c when outdoor temperature is 1-2c. The heat pump would run 1-1.5 hours and stop for 1 hour. I thought 48c is low enough as the design temperature is 51c. But I read someone's post suggests to reduce curve shift to minimal so the heat pump run constantly instead of cycling. Today, the temperature feels even lower than yesterday. After some experiments, I changed the curve shift from +5c to -4c. Wow, what a difference it makes. The indoor temperature almost maintain at a constant level and the HP kept running with target flow temperature like 38c. At 9am, the battery still held 80% charge and it lasted until 9pm. Then I let home assistant switch the HP to eco mode now (essential turned off and let the house cool a bit). It will switch to comfort mode again when off-peak period begins at 11pm. So I can use all off-peak tariff for my heating now. That will save me ££ over this winter.


r/ukheatpumps • • 5h ago

Help/Advice Weather dependent mode flow rates and such

4 Upvotes

I’m testing out the weather dependent mode, but mostly the rads right now. Is my flow rate and returning temp too low during the day at 7l/min?

Previous WD curve:

  • Rads: 45 degrees at -3, 35 degrees at 16
  • UFH: 35 degrees at -3, 27 degrees at 16

The leaving temp is 40 and returning temp (inlet plate heat exchanger) is 33. I noticed that the flow rates in the morning and afternoon is 7l/min, and the rads don’t feel particularly warm. If I turn the UFH off, the rads feel slightly warmer but the flow rates stay at 7l/min.

Yesterday, it was 21 degrees around 8am and then the heating turned off. It was set to be 22 degrees from 12:30pm-4pm so that it’s slightly warmer during peak hours (room temp is targeting 18 degrees during 4-7), but the temp went from 19.8 degrees to 20.3 degrees after the 3 hours. I target 21 degrees from 7pm to 12:30pm, and my Myson Touch has a threshold of 1 degree.

I’ve changed it to be 22 before the peak hour slots because the house was 19.5 degrees after the peak hour the day before. I just want the house to be warmer before the peak hour, and I understand that my system is just on/off for heat.

I checked the flow rates and stuff at 9pm after being out, and the house was still demanding heat, but the rads were the same. Just barely warm, and temp was 19.8 when I got back.

Since it was 48-60 hours since I changed to WD mode, I changed it again last night:

  • Rads: 45 degrees at 0, 35 degrees at 16

After the system restart, the flow rate changed to 15l/min and then it heated up the house within an hour. The LWT was 43 and returning temp was 40.

This morning, it's somewhat the same with the returning temp. The LWT is 44 and returning temp is 33-34, and flow rate is 7l/min. It's been demanding heat since 6am and the house is 20.3 degrees.

I don't know the exacts but 7l/min seems to be the lowest that it runs. There's no error messages. I cannot change the delta T for the rads even if I change it to fan coil since it's an additional zone, and it's always locked to 12 degrees. Delta T for UFH is 5 degrees.

I don't have battery or solar. I'm on the Eon heat pump tariff.


r/ukheatpumps • • 6h ago

Help/Advice Mitsubishi Ecodan Tips/Advice

3 Upvotes

All I am looking for is tips or advice on the system I have installed at my property. I have been tinkering now for a while and think I have the best setup I can get with what I have. The energy and heating system i have is:

- 12kw R290 Ecodan
- 250l tank
- 30 Aiko Gen 3 540w Solar Panels
- 2xBAT 10 Sigenstor batteries
- 10kw inverter

I have lowered flow temp max to 43 degrees Celsius and the heat pump will run at 1.1kw-2.0kw while maintaining temp at 20 degrees. At this max flow temp the house will heat by about 0.1-0.2 degrees per hour but the system usually runs at between 33-38 degrees when maintaining temperature.

On cold grey days like we have just had, I’m in between Sheffield and Lincoln so it has been around freezing for most of the day recently, we just have enough battery to last the day with some solar which I’m happy with. The heat pump used 20kwh max on the coldest day and that included a legionnaires cycle.

I pair this with a TOU tariff that I use mainly for charging my car but also charging the home batteries. During this time I have the heating on from 2am-5am to raise temp to 21 degrees and then at 6am when that low cost energy finishes I drop temp to 21 degrees. This then means the heat pump turns off for about 2-3 hours by which point I start to get some solar.

I feel i have it as good/efficient as I can get it. I do need to replace some single panel radiators with K2/type22 which would improve efficiency further but at the moment that cost can wait.

Any tips or advice is welcome.

Cheers.


r/ukheatpumps • • 14h ago

Should we make the jump?

Thumbnail
gallery
7 Upvotes

We’re using 50–85 kWh of electricity per day in winter due to having an electric central heating and hot-water setup.

We do not have an electric vehicle and are currently on a fixed tariff.

Our property:
• ⁠Three-bedroom detached house, occupied by two adults.
• ⁠Cavity walls insulated approximately 15 years ago.
• ⁠Loft insulation approximately 300mm (2025)
• ⁠Triple glazing throughout (2025)
• ⁠Radiators replaced approximately two years ago as part of a full house refurb when the electric boiler was installed.

Our current heating system:
• ⁠EHC Fusion Comet V2 electric boiler (14.4kW).
• ⁠EHC Neptune 180-litre hot-water cylinder.
• ⁠Central heating typically switched on manually for around 4 hours during colder evenings.
• ⁠Hot water programmed for 6am–8am daily but we have recently reduced this to 1 hour and noticed no difference so that’s good.
• ⁠Separate immersion heater switched off.
• ⁠Central heating isn’t used during summer and early autumn. We started using it again around mid-October.

Our electricity tariff is approximately 26.61p/kWh, plus a daily standing charge of 50.55p.

We’re using approximately 18,000 kWh per year and this is costing us an eye-watering amount.

Following a post on here this week, which opened our eyes, we have had a quote for an air source heat pump, which after taking into account the available grant, would cost £4000 approx.

The fear I now have is that many people on here have said we would replacing an awful heating method for a bad heating method yet others are saying (including the company we may use to install it), that with the correct tariff and an ASHP, would reduce our bills to potentially a fifth or a quarter or what they are now meaning the ASHP would pay for itself after 12-18 months.

I just don’t know who to believe…

Here is the spec we have been quoted - can anyone offer valuable advise?


r/ukheatpumps • • 16h ago

EcoNet24

8 Upvotes

Anyone else's Grant Aerona (or other ecoNET kit) lost its connection to econet24 this evening (UK, Tue 24 Nov)?

The econet24 app/site shows my device as inactive, and the server light on the Wi-Fi hub is flashing.

What I've checked:

Controller shows "Connection with controller: Connected" and "Connection with server: Not connected"

Hub is on Wi-Fi with a valid IP and strong signal (-48 dBm)

Hub's local web page loads fine and shows main server

econet24.com as "Disconnected"

econet24.com login page loads normally

Hub firmware 3.2.3806

So everything looks fine on my side, and it just can't reach their server


r/ukheatpumps • • 16h ago

Samsung 8kw, flush help

2 Upvotes

Hey all, ive got an Samsung 8KW, that i neef to flush the HEX through.

Ive got a Rothenberger Rosolar flush machine, but my pipes have a slightly smaller connection to the flow and returns on the Unit.

Is there a specific adapter i can get.

Believe the flow and returns on heat pulp are 28mm, and my pipes are 22mm connections.

Would obviously need to be female to male adapter.
Im just sure on the actual name of said adapter