r/ukheatpumps • u/BunchThin5925 • 1h ago
r/ukheatpumps • u/Begalldota • 23h ago
Heads Up: No AI copy & pasting
There’s been an influx of activity in this sub recently as the weather has turned colder and gas prices have continued to spike - which is awesome!
Unfortunately it seems to have dragged in one of the worst things about the modern internet, which is people copy and pasting advice from AI chat bots and presenting it as their own work (also often while trying to promote their business).
I don’t see the point in a sub which is just bots talking to other bots, so any content of this type will now be removed. Please report any comments or posts as per Rule 7 if you suspect it and we’ll review - let’s keep the sub genuine.
r/ukheatpumps • u/tomasmcguinness • 17h ago
Help/Advice Real gas boiler performance compared with real heat pump performance
It's a little over two months since my Kronoterm Adapt was installed and so far, it's keeping us all toasty warm!
Two questions get asked a lot in these forums:
a) Will a heat pump keep my house warm?
b) Will it cost more to run than a boiler?
I'm in the rare position of having all their boiler performance data recorded in Open Energy Monitor, so I can provide pretty direct comparisons before and after.
To expose this data, I've created this webpage: https://boiler-vs-heatpump.tomasmcguinness.com/

In an effort to make better comparisons, it looks for similar outdoor temperature patterns. It finds the best match and then shows how the input of gas/electric compares with the output of heat.

In this example, we can see it ran with a 370% efficiency, delivering more heat than the boiler.
I need to make some additions, to make it more useful. Pricing would be one, but that's more difficult to work out.
I think having "time at target indoor temperature" is probably useful too.
What do you think?
I've also had a go at sharing the heat loss for my property https://heatlossdb.org/h/RvaO-HYJXPLCsG2Uyh5V5w
r/ukheatpumps • u/deej_94 • 13h ago
Am I being ridiculous by considering this Aira quote?
Sorry if this is a long one. I've been interested in heat pumps for a long time and having moved into our new home a year ago and assessing our current heating situation we are noe about to take the plunge. We're in a 3 bed semi detached house in London.
Annoyingly, I didn't realise our mortgage offered £2000 cash back if we get a heat pump in the first year. I've managed to get that deadline extended until the end of Jan, but it's obviously tight.
I first reached out to Octopus, who weirdly were pretty much trying to convince me not to go with them. The quote I got from filling out the online form was around £5.5k. They said they definitely wouldn't be able to install before the end of Jan, more like summer next year.
I then got someone from Aira round, who after having a look, ended up quoting us £9.2k for a 8kw heat pump, 200L water tank, 60L buffer tank and 3 rad replacements. Pending the heat loss survey which is booked for next week (had to put forward £150 for the survey). They have me booked in for an install mid Jan, so I would be able to get the cashback from my mortgage, meaning the cost is £7.2k.
Since then I had been looking at other options and quotes, here is a summary of all I've got so far.
- Octopus £5.3k. Includes heat pump and hot water cylinder, doesn't mention what kw or size of tank.
- Aira £7.2k (including mortgage cashback). Includes 8kw Aira heat pump, 200L water tank, 60L buffer tank, 3 rad upgrades.
- Eon next £6.5k. Includes Bosch CS2000 12kw heat pump 210L cylinder.
- Heat Geek £5.5k. Includes Viessmann Vitocal 200-A ie B08 8kw pump, 210L cylinder, 5 rad upgrades.
Other than Aira, no one else has been round. Like I said Octopus were trying to talk me out of it and all the other quotes are just from online forms.
I get that Aira are a sort of more premium option. One thing I'm not super keen on is their whole pay £20 a month to keep your warranty and other features. But I do get the impression they have good aftercare.
Am I mad for considering the Aira quote which (without my mortgage cash back) is 3-4k higher than all the others? I'm also aware that if I miss the January cashback window, there's also the end of free VAT coming up in March.
r/ukheatpumps • u/SodaCanSuperman • 20h ago
Help/Advice Struggling to figure out a good hot water schedule - Grant Aerona R290 + 200L slimline cylinder
Hi all,
New heat pump owner here, struggling to figure out a good hot water schedule that meets our needs.
It's just the two of us living in the house, but it feels like we never have enough hot water. I shower in the morning around 6:30-7am and my wife around 8pm.
Originally when we had the cylinder installed but the heat pump not yet commissioned it felt like we had hot water coming out of our ears! We used the immersion tank just an hour or so in the morning and an hour in the evening and that lasted forever and was piping hot all day.
I understand the heat pump is much slower, but despite having an hour and a half in the morning, an hour and a half around midday, and an hour at midnight (Octopus Cozy cheap times), halfway through my shower this morning the hot water ran out which also happened yesterday. My wife said the water is warm but not as warm as she'd like.
The water is set to 48 degrees with a 5 degree hysteresis, which can't be lowered any more. I believe the installer set up a 15 minute overrun in case it didn't hit the required temperature in the time allowed.
By my logic, despite the temperature probe being in the lower third of the cylinder, when the heat cycle is done the temperature should be reading 48 for quite a while? It shouldn't lose heat on the reading unless any hot water is used and therefore filling cold water in the bottom.
Despite this, I woke up this morning with the hot water temperature reading 14 degrees C and while it was nice for the majority of my shower it then suddenly ran out towards the end. I can't understand why the entire tank isn't full of nice 48 degree water when in the last 8 hours or so it has ran (in theory) for 2 and a half hours.
The installers response originally was for me to put on more hot water times in the schedule (as I have done) but seems to still not to be enough. At first I was thinking that cold water is seeping in and slowly lowering the temperature, and I'm still 50/50 on whether that is the case, but they say unless hot water is being let out then cold water can't get in which makes sense.
Any ideas or recommendations? I'm concerned that something is wrong. The installers originally said if no hot water is used it should hold the temperature for days but it seems like it can't hold it much at all even for a couple of hours.
r/ukheatpumps • u/bureaucracysausage • 14h ago
Help/Advice Why won’t my dads heatpump stop short cycling?
My father had a heatpump installed around Easter this year. All was ok but now the cold weather is here it’s just short cycling. The installer has told us it’s normal which I know it’s not. I’ve complained and they are stringing me along.
I contacted the manufacturer who has helped me change some flow rate settings which should bring the temp down however it’s still short cycling.
We have had one day where it randomly worked ‘normally’ for a few hours then back to short cycling again.
My father is elderly and spent £1 a day on electric before Easter, now he is spending a fortune.
It’s not about the money, it’s about getting the darn thing working as efficiently as possible.
Daytime temp is set to 20°, night time is 19°. All TRV are open fully.
Any thought would be very helpful.
r/ukheatpumps • u/Jay638 • 1d ago
Home Assistant card for Grant Aerona
I'm quite pleased with this (Claude helped) so I thought I'd share. Its based on the Grant Smart Controller display.
When the HP is running the blades turn and it and the compressor change to orange. Either the rads or the cylinder will highlight depending on current mode.
Also shows flow temps, flow rate, rpm, compressor frequency, input and output power, cylinder water temp, house thermostat temp.
You'll need the Econet300 integration https://github.com/jontofront/ecoNET-300-Home-Assistant-Integration.
[One thing I did have to fix "sensor.grant_aerona_r290_circuit_1_actual_temp" seems to come through as text rather than as a number in .c. I think a bug with the integration. So I created a template helper to flip that into a normal number. Its called "Circuit 1 Actual Temp with °C unit of measurement" and the template state is "{{ states('sensor.grant_aerona_r290_circuit_1_actual_temp') }}". Device class is temp, and unit of measurement is .c]
type: picture-elements
image: >-
data:image/svg+xml;utf8,<svg xmlns='http://www.w3.org/2000/svg' viewBox='0 0
600 340'><g fill='none' stroke='%239ca3af' stroke-linecap='round'
stroke-linejoin='round'><path d='M290 102 H327 M363 102 H540 M410 102 V128
M470 190 V215 M540 102 V124 M540 198 V215 M540 215 H290' stroke-width='5'/><g
stroke-width='3'><rect x='40' y='95' width='250' height='130' rx='14'
fill='%23808080' fill-opacity='0.08'/><rect x='62' y='225' width='28'
height='8' rx='2'/><rect x='240' y='225' width='28' height='8' rx='2'/><circle
cx='110' cy='160' r='50'/><circle cx='110' cy='160' r='44'
stroke-width='1.5'/><circle cx='110' cy='160' r='7'/><path d='M178 108 V212'
stroke-width='1.5'/><rect x='200' y='120' width='60' height='80'
rx='24'/><path d='M200 140 H260 M200 180 H260' stroke-width='1.5'/><circle
cx='345' cy='102' r='18'/><path d='M339 93 V111 L355 102 Z'/><rect x='400'
y='128' width='80' height='62' rx='8' fill='%23808080'
fill-opacity='0.08'/><path d='M416 136 V182 M432 136 V182 M448 136 V182 M464
136 V182' stroke-width='2'/><rect x='510' y='124' width='60' height='74'
rx='16' fill='%23808080' fill-opacity='0.08'/><path d='M540 124 V134 L558 141
L522 154 L558 167 L522 180 L540 187 V198' stroke-width='2'/></g></g><text
x='168' y='322' text-anchor='middle' font-family='sans-serif' font-size='17'
font-weight='bold' fill='%236b7280'></text></svg>
elements:
- type: conditional
conditions:
- condition: numeric_state
entity: sensor.grant_aerona_r290_heat_pump_compressor_frequency
below: 1
elements:
- type: image
image: >-
data:image/svg+xml;utf8,<svg xmlns='http://www.w3.org/2000/svg'
viewBox='0 0 600 340'><g transform='translate(110 160)'
fill='%239ca3af' fill-opacity='0.25' stroke='%239ca3af'
stroke-width='2'><path d='M0 0 C10 -8 14 -28 2 -40 C-10 -32 -10 -10 0
0 Z'/><path d='M0 0 C10 -8 14 -28 2 -40 C-10 -32 -10 -10 0 0 Z'
transform='rotate(72)'/><path d='M0 0 C10 -8 14 -28 2 -40 C-10 -32 -10
-10 0 0 Z' transform='rotate(144)'/><path d='M0 0 C10 -8 14 -28 2 -40
C-10 -32 -10 -10 0 0 Z' transform='rotate(216)'/><path d='M0 0 C10 -8
14 -28 2 -40 C-10 -32 -10 -10 0 0 Z'
transform='rotate(288)'/></g></svg>
style:
left: 50%
top: 50%
width: 100%
transform: translate(-50%,-50%)
pointer-events: none
- type: conditional
conditions:
- condition: numeric_state
entity: sensor.grant_aerona_r290_heat_pump_compressor_frequency
above: 0
elements:
- type: image
image: >-
data:image/svg+xml;utf8,<svg xmlns='http://www.w3.org/2000/svg'
viewBox='0 0 600 340'><g fill='none' stroke-linecap='round'
stroke-linejoin='round'><path d='M290 102 H327 M363 102 H410'
stroke='%23f97316' stroke-width='5'/><path d='M470 215 H290'
stroke='%2360a5fa' stroke-width='5'/><g stroke='%23f97316'
stroke-width='3'><circle cx='345' cy='102' r='18'/><path d='M339 93
V111 L355 102 Z' fill='%23f97316'/><rect x='200' y='120' width='60'
height='80' rx='24' fill='%23f97316' fill-opacity='0.2'/><path d='M200
140 H260 M200 180 H260' stroke-width='1.5'/></g></g><g
transform='translate(110 160)'><g><animateTransform
attributeName='transform' type='rotate' from='0' to='360' dur='1.5s'
repeatCount='indefinite'/><g fill='%23f97316' fill-opacity='0.35'
stroke='%23f97316' stroke-width='2'><path d='M0 0 C10 -8 14 -28 2 -40
C-10 -32 -10 -10 0 0 Z'/><path d='M0 0 C10 -8 14 -28 2 -40 C-10 -32
-10 -10 0 0 Z' transform='rotate(72)'/><path d='M0 0 C10 -8 14 -28 2
-40 C-10 -32 -10 -10 0 0 Z' transform='rotate(144)'/><path d='M0 0 C10
-8 14 -28 2 -40 C-10 -32 -10 -10 0 0 Z' transform='rotate(216)'/><path
d='M0 0 C10 -8 14 -28 2 -40 C-10 -32 -10 -10 0 0 Z'
transform='rotate(288)'/></g></g></g></svg>
style:
left: 50%
top: 50%
width: 100%
transform: translate(-50%,-50%)
pointer-events: none
- type: conditional
conditions:
- condition: numeric_state
entity: sensor.grant_aerona_r290_heat_pump_compressor_frequency
above: 0
- condition: state
entity: sensor.grant_aerona_r290_3_way_valve_state
state: central_heating
elements:
- type: image
image: >-
data:image/svg+xml;utf8,<svg xmlns='http://www.w3.org/2000/svg'
viewBox='0 0 600 340'><g fill='none' stroke-linecap='round'
stroke-linejoin='round'><path d='M410 102 V128' stroke='%23f97316'
stroke-width='5'/><path d='M470 190 V215' stroke='%2360a5fa'
stroke-width='5'/><g stroke='%23f97316' stroke-width='3'><rect x='400'
y='128' width='80' height='62' rx='8' fill='%23f97316'
fill-opacity='0.25'/><path d='M416 136 V182 M432 136 V182 M448 136
V182 M464 136 V182' stroke-width='2'/></g></g></svg>
style:
left: 50%
top: 50%
width: 100%
transform: translate(-50%,-50%)
pointer-events: none
- type: conditional
conditions:
- condition: numeric_state
entity: sensor.grant_aerona_r290_heat_pump_compressor_frequency
above: 0
- condition: state
entity: sensor.grant_aerona_r290_3_way_valve_state
state_not: central_heating
elements:
- type: image
image: >-
data:image/svg+xml;utf8,<svg xmlns='http://www.w3.org/2000/svg'
viewBox='0 0 600 340'><g fill='none' stroke-linecap='round'
stroke-linejoin='round'><path d='M410 102 H540 V124'
stroke='%23f97316' stroke-width='5'/><path d='M540 198 V215 H470'
stroke='%2360a5fa' stroke-width='5'/><g stroke='%23f97316'
stroke-width='3'><rect x='510' y='124' width='60' height='74' rx='16'
fill='%23f97316' fill-opacity='0.25'/><path d='M540 124 V134 L558 141
L522 154 L558 167 L522 180 L540 187 V198'
stroke-width='2'/></g></g></svg>
style:
left: 50%
top: 50%
width: 100%
transform: translate(-50%,-50%)
pointer-events: none
- type: state-label
entity: sensor.grant_aerona_r290_fan_speed
style:
left: 18%
top: 71%
color: var(--primary-text-color)
font-size: 12px
- type: state-label
entity: sensor.grant_aerona_r290_heat_pump_compressor_frequency
style:
left: 38%
top: 71%
color: var(--primary-text-color)
font-size: 12px
- type: state-label
entity: sensor.grant_aerona_r290_actual_flow_temp
prefix: 'Flow '
style:
left: 57%
top: 19%
color: '#f97316'
font-size: 12px
font-weight: bold
- type: state-label
entity: sensor.grant_aerona_r290_flow_rate
style:
left: 57%
top: 42%
color: '#38bdf8'
font-size: 12px
font-weight: bold
white-space: nowrap
- type: state-label
entity: sensor.grant_aerona_r290_actual_return_temp
prefix: 'Return '
style:
left: 60%
top: 72%
color: '#60a5fa'
font-size: 12px
font-weight: bold
- type: state-label
entity: sensor.grant_aerona_r290_circuit_1_actual_temp_with_degc_unit_of_measurement
style:
left: 73%
top: 22%
color: var(--primary-text-color)
font-size: 12px
- type: state-label
entity: sensor.grant_aerona_r290_actual_dhw_temp
style:
left: 90%
top: 22%
color: var(--primary-text-color)
font-size: 12px
- type: state-label
entity: sensor.grant_aerona_r290_electrical_power
prefix: '⚡ In '
style:
left: 28%
top: 81%
color: '#eab308'
font-size: 14px
font-weight: bold
white-space: nowrap
- type: state-label
entity: sensor.grant_aerona_r290_thermal_power
prefix: '🔥 Out '
style:
left: 28%
top: 92%
color: '#f97316'
font-size: 14px
font-weight: bold
white-space: nowrapr/ukheatpumps • u/KassyBrass • 12h ago
Help/Advice Portable for renters?
Hi folks,
Since it's winter, I'm hoping some air conditioning options are on sale to help with what will doubtlessly be a horrible summer again next year.
I'm leaning towards air pumps over AC units for the smaller environmental costs. But I'm a renter, so would need a portable unit that I can take from place to place.
Are there such things as portable air pumps? Does anyone have any experience with them? I'm struggling to find anything online that doesnt look like a scam.
Thanks!
r/ukheatpumps • u/geckodancing • 13h ago
Does anyone have any experience with Hisa heat pumps?
I've come across a few good reviews, but would be interested to hear from anyone who has had one installed.
r/ukheatpumps • u/Appropriate_Bell743 • 19h ago
First month heat-pump grants applications top 10,000
r/ukheatpumps • u/SeaBeach6482 • 20h ago
Zoning query
Hi all, I'm finalised onto two quotes. One is Eon and another is a local company.
Locla company is advising to have zoning valves for underfloor heating and the radiators with a buffer tank for the underfloor heating.
Underfloor heating is in kitchen and dining room (red) and central heating is rest of the house. Manifold for underfloor heating is in the kitchen too in a cupboard
Heatloss is about 5.05kw
Valiant smart thermostat is going in the hallway - green dot (not in underfloor heating area) and was wondering whether this is the right way to go, or whether this company is doing this to not have to do any pipework.
Should I have it zoned or have it as a whole system. Images of downstairs and cylinder area.
Quote for this is 16.3k before removal of grant 7.5k.
Thank you for responses in advance.
r/ukheatpumps • u/Training_Apricot9883 • 21h ago
I installed solar panels, a heat pump and a battery – now I save £3,500 a year
r/ukheatpumps • u/beefymcmoooo • 19h ago
Help/Advice Investigating heat pump
Hello all, I'm looking to see if I can get a heat pump installed at my home. Looking at the placement guidelines I don't think I will have the space to the side of my house where the current boiler is located. So the best placement would be slightly away from the house, meaning that some pipes may need to be buried. Do any of you have experience with this and will the usual installs include this if I went with EON or Heat Geek? Either that or the pump could be mounted on the wall, but I understand that it has it's own difficulties. Thanks in advance for any help.
r/ukheatpumps • u/free-reign • 20h ago
£11k for batteries. Sane from Octopus ?
From Octopus
The usage calculation is based on the property survey and the estimated annual consumption (EAC) of 7555-9000 kWh, which accounts for both your household needs and heat pump usage. See the image below for current usage
r/ukheatpumps • u/kyjoely • 23h ago
Tarrif options for my house with solar, battery, heat pump, and two EVs?
With the increase in energy prices in January it's got me thinking about whether I shoud jump providers to someone else. I'm on IO.G at the moment with Agile outgoing hooked up to my Sigen solar/battery system the AI system of which optimises my export. I'm an all in electric house with 14 panels, 20 KW of battery storage, two EVs and a (Aira) heat pump. So my electricity usage comes out at about 7000 KWh per year at the moment.
The thing that keeps me with Octopus at the moment is the Agile outgoing as that has really paid dividends paired up with the Sigen system. While the EV Tarrifs of EDF and E.ON look better for import, the fact they don't offer agile export stops me switching. That is until I saw E.ON optimise which looks really promissing. My only concern, however, is how it is going to play with the heat pump and, more importantly, the EV. While I work from home and can charge my car on a flexible schedule, my wife doesn't and she does the bulk of the EV miles and so is more constrained in when she can charge.
So does anyone have any experiences of E.ON Optimise with a comparable-ish setup? If so how's it working out?
r/ukheatpumps • u/rickyknowles • 22h ago
Ecodan not heating
Our Ecodan has stopped heating the house and no hot water. Was set on a compensation curve and been working perfectly for the last 3 years.
All of a sudden, the pump is turning if I turn it off and on again but no heat or hot water. Any ideas about what’s going on or how to resolve it? TIA
r/ukheatpumps • u/leebow55 • 1d ago
Removing a radiator that’s tee’d from main
Hello there, we are removing the kitchen radiator as moving to Water underfloor heating.
I am a little unsure how best to remove the radiator (via instructions to a plumber)
Either
Remove radiator and cap off the flow and return legs that come down the wall.
Or
Take up the bathroom floor, or from downstairs utility ceiling and block off the tee’d section
The flow and return for this radiator are tee’d off from the main 22mm core, it is tee’d off the bathroom radiator. You can see this kitchen radiator was the only one left on microbore as repiping this one would have been quite destructive at the time.
r/ukheatpumps • u/criminaloftoot • 21h ago
Help/Advice New home with a heat pump, solar panels, and multiple cylinders. No idea what I’m doing!
galleryr/ukheatpumps • u/Vallance95 • 1d ago
Vaillant aroTHERM Pro 7kW vs Plus 5kW – which would you choose for a 6.4kW heat loss?
I've recently had a survey completed and I'm trying to decide between two heat pumps.
Property and heat loss:
- Floor area: 91.46m²
- Calculated heat loss: 6.4kW
- Design outside temperature: -3.6°C
- Target indoor temperature: 21°C
- Ventilation heat loss: 2.46kW
- Estimated annual space heating demand: 15,150kWh
Heat pump options:
- Vaillant aroTHERM Pro 7kW – guaranteed efficiency of 340–375%.
- Vaillant aroTHERM Plus 5kW (anthracite) – guaranteed efficiency of 345–380%.
I'm leaning towards the 5kW Plus because of its lower minimum modulation, quieter operation and slightly better predicted efficiency. However, I'm concerned about whether it has enough capacity on the coldest days.
I'm also planning some improvements to the property:
- Increasing loft insulation from approximately 100mm to 300mm.
- Draught-proofing windows, doors and other gaps.
- Installing thermal curtains.
The upstairs ceilings currently account for 342W of the calculated heat loss, and ventilation accounts for around 38% of the total.
My thinking is that there are some simple improvements to improve my heatloss and I don't want to end up with an oversized heat pump for the next 15–20 years.
My questions are:
- Would you be comfortable installing the 5kW Plus with this heat loss?
- What is the real-world output of the 5kW Plus in sub-zero temperatures?
- Would the 7kW Pro be oversized if I did some simple improvements e.g. extra loft insulation, plugging gaps etc.
- How much weight would you give to the lower minimum modulation of the Plus?
Edit Thank you so much everyone for commenting. So many good points and it's given me lots of food for thought.
r/ukheatpumps • u/Accomplished_Quit577 • 1d ago
Help/Advice How low to set the Curve?
Think we may have way over-specced our system and now it’s running a bit too efficiently. Initially designed to -45°C at -3 but the house is holding heat for the past couple days above 20°C from what I’ve set it to and the curve is at 0.7 or 37°C at -3 and I could go lower.
From my own calculations our heat loss was approx 5.7kW but it is probably closer to 4kW but we installed a Grant R290 6.5kW. Haven’t fully tested it at those outdoor temps and it’s not windy, should I just wait a while longer to see how it will hold up?
r/ukheatpumps • u/Tessarext • 1d ago
Constant fault in Grant Aerona A2W heat pump
Hey All,
I am having issues with my grant aerona air to water heat pump, model HPID6R32.
We recently had a power flush done and a service done, and I am getting an FU alarm and some times P1 alarm.
See 4 images attached.
Image-1: over view of the hotpress room
Image-2: bleed point(red) and bypass valve setting (purple)
Image-3: Mag filter after 2 weeks of power flush.
Image-4: Fu alarm code
If you see image-2, I constantly find small airpockets at those bleed point, they directly on path of demand hot water inlet and outlet.
I get the FU alarm every 18-26 hrs and p1 alarm every 2-3 days.
I have tried the following:
- Clean mag filter
- Keep bleeding air as shown in image-2z
- Set Bypass valve to lowest setting of 0.1
Can any one please help me out.
r/ukheatpumps • u/suspicious_muffin_78 • 1d ago
Help/Advice Installer recommendations - Cambridgeshire
Hi, I'm looking for recommendations for heat pump installers that cover Cambridgeshire and can install a system with ducted fan coil units upstairs (FCUs in the loft) and wall mounted FCUs downstairs. I've been eyeing up the Panasonic Aquarea system with their hydronic FCUs but I'm open to other options. I found a couple of potential companies but one of them will only do installs whilst the house is being built and the other isn't MCS certified so they can't do the BUS grant. Bonus points if the installer can also install solar panels and a Fogstar battery + inverter system.
r/ukheatpumps • u/idarryl • 1d ago
Anyone used Heatable for a heat pump with Adia Thermal?
I’m renovating near Chelmsford and Heatable reckon they can do a 10 kW Vaillant and a 300 litre cylinder for about £8,800 after the grant. Seems pretty reasonable for a big national installer. They’ve told me Adia Thermal is included.
Has anyone had Heatable fit theirs? How was the install, and were they any good at sorting things out afterwards?
The bit I’m unsure about is Adia. I get that it’s meant to balance the radiators automatically, but does that mean the installer leaves more of the setup for Adia to sort out after they’ve gone? We’ll have new radiators and underfloor heating. What actually gets checked before they leave, and how has it been to run through winter?
Quick quote sense check
Sorry for including solar too. I figured quite a few people here have both, and I’d like one company to do both jobs. Heating prices are after the grant and include underfloor heating and radiator fitting. No one’s priced the radiators themselves yet.
- Heatable (£47k total) · £25.9k heating + £21.1k solar, with 19 panels, an 18 kWh battery and whole-home backup.
- Better Planet (£54.1k total) · £28.5k heating + £25.6k solar, with 18 panels, an 18 kWh battery and whole-home backup.
- JMR Heating & Energy (about £43k total) · £22.1k heating + about £20.8k for a similar solar and battery setup with backup.
I’m leaning towards Better Planet because they’ve done more work on the heating design so far, but £7k more than Heatable is a fair chunk. Does anything jump out at you?
r/ukheatpumps • u/ArtisticWatch • 1d ago
Buying a 3 bedroom 1950 cavity semi - looking at a new system.
We're in the late process of buying a 3 bedroom house. The loft has been coverted.
Current system is a gas boiler & Unvented water cylinder.
Is it worth installing Solar panels, battery and heat pump? We'll have approximately £15k left over from the house sale & purchase.
Given the rising energy costs. We're planning on getting rid of the gas to the house (new induction hob ect)
r/ukheatpumps • u/ryuken5126 • 1d ago
Switch from System boiler worth it
Hi, Wondering if I should switch out system boiler with ASHP or keep the old setup and spend the money on all year round AC-heating/cooling
Old Victorian property over 3 floors. Would say we are high usage household due to WFH, plenty showers etc
If went down the AC route, I would do the majority of heating via AC and use the old boiler for heating the water mainly.
Looking for peoples thoughts on this or help question the possibilities as I'm completely new to all this.