r/hvacadvice • • Mar 02 '26

General Information About Bans and Rules

0 Upvotes

There has been an uptick on posts and complaints about mods banning. Please be advised, there are rules for the page. No ads (includes promotions for a company), Reddits rules, no crossposting, transparency and safety (this is a big one; we want homeowners to be safe, if you provide unsafe practices or advice (blacklisted items) or tell a user to dm you, the comment will be removed and you may get banned), blacklisted topics (basically topics that homeowners should not be fixing themselves, gas, some high voltage), civility, no companies asking for surveys, advertisements or general questions, and no market research or ai/SaaS.

Posts complaining about this are not allowed either. We are all reasonable and work in the trade, talk to us through ModMail and we can come to a solution. Complaining or namecalling will usually result in a ban, so be civil.

Remember, we are doing this in our freetime to help homeowners with their units, both the users and mods. The mods in this group are in the trade and have day jobs as all of you do. I've been in this trade for 10 years and still do hvac as my job, just traveling now for a manufacturer. Similar with every mod. It is actually a requirement to be a mod, you have to be in the trade, be approved, have good history in the sub and provide enough time to moderating it.

I thank you for your time and if you have any questions, you can comment on this or send us a mod message. No DM's, we will not answer these. Only ModMail.


r/hvacadvice • • Nov 13 '25

READ THIS I am assuming this is not normal.

177 Upvotes

I was loading the car for work when I saw this. It felt and smelled like steam not smoke. Did I just catch it at the end of the cycle or is there a mechanical problem such as a stuck motor? It was 40° at the time and no rain. Heat was set to 70 and the house was 70.


r/hvacadvice • • 44m ago

Help patching irregular junction..?

Thumbnail
gallery
2 Upvotes

Hi and howdy; I’m green as can be and may have oversold my confidence trying to impress her parents with what I thought would be an easy repair (how hard could it be?) I have a circular feed going to a rectangular hole to spread the heat around the upstairs,

Only problem is that the round exit and rectangular entrance are located right on top of each other and offset to boot.

I am unclear what the original installer’s vision was with this, and would appreciate guidance on how to proceed! (Please excuse the shoddy photos, here’s a random protractor to give a sense of how out of my depth I am)

Tl;dr how do I make this wonky connection work? Thank you 😅🙏🏼


r/hvacadvice • • 16h ago

Furnace Sanity Check...Tune-up turned into $3,600 in quotes on a working 2017 furnace

Thumbnail
gallery
30 Upvotes

**Edited for completeness. Including the readings and estimates in the message body that didn't get submitted the first time**

Hey everyone,

I requested a tune-up on my 2017 2-stage gas furnace (F9MVE0801716A3) in Southwest Ohio. I didn't see any symptoms, holding 70°F fine. I wasn't home for the tune up and my wife wasn't very helpful explaining why the tech left us with three estimates totaling ~$3,600. I'd appreciate a quick sanity check on whether anything here is actually urgent and if it is reasonable.

Tech's readings:

Delta T: 35°F on low fire / 53°F on high fire (rating plate specifies 30–60°F / 40–70°F)

Manifold gas pressure: 1.8" WC low fire / 3.4" WC high fire (specification is 1.3–1.7 / 3.2–3.8)

Flue CO: Approximately 64 ppm (not sure whether raw or air-free)

Flame sensor: 1.1 µA before cleaning, 1.7 µA afterward

Indoor humidity: Approximately 47% RH, although the Fieldpiece screenshots appear to have the probes mislabeled/swapped

Recommendations/estimates:

$849 – Ignition repair: Replace flame sensor and hot-surface igniter and clean burners. The technician described the burners as heavily rusted and the igniter as having heat-stress marks, although it reportedly tested within range. I wasn't provided a photo of the igniter.

$1,149 – UV air purification system: Replace the existing UV system because it's no longer working. I have a spare bulb that I haven't tested yet.

$1,600 – AprilAire fan-powered humidifier: Recommended because indoor humidity reportedly drops to 37–40% during winter. We currently measure around 47% RH and haven't noticed any dryness.

Quotes:
Would you consider any of these repairs urgent based on the information/photos? I guess specifically, should the heat exchanger rust or burner condition be looked into further, or does this look more like preventative recommendations and optional upgrades? Would you get a second opinion before approving the ignition repair?


r/hvacadvice • • 2m ago

Best Heating/AC Setup for a Small Insulated Shed/Home in Southwestern Ontario?

1 Upvotes

I'm moving into a small standalone building on a farm property. It's not the main house, but will be a 2 person bedroom/hangout space. (Bed, TV, Mini fridge)

Some details:

  • Approximately 19 ft x 9 ft (about 170 sq ft)
  • Roughly 7 ft ceilings
  • Will be fully insulated (will be new and redone insulation)
  • Has its own electrical panel/breaker, but I don't know the electrical specs yet
  • Around 4 outlets currently
  • Located in Southwestern Ontario
  • Existing old through wall-mounted AC unit that will be replaced ( 2-3ft wide 1ft tall rectangle through the wall)
  • Timeline is about 2-3 years of use

A few things:

  • Price matters and i am ok with being cold but obvisoly still needs some heat
  • Is a dehumidifier recommended for a building of this size in Ontario, or would a properly sized mini-split handle humidity well enough?
  • Any recommendations for quiet systems? Noise is a big consideration since it's essentially a bedroom.
  • Phone/app control would be nice but isn't a necessity.
  • Some construction/work is fine since we're already planning insulation upgrades.

For a 170 sq ft insulated space, what would you install if cooling performance, efficiency, and low noise were the priorities?


r/hvacadvice • • 10m ago

Furnace short cycling

1 Upvotes

When thermostat calls for heat, burners on Lennox gas furnace will turn on for about 4 minutes and shut off. Temp still not reached. A few minutes later, burners turn on again, then off a few minutes later. Home is at a normal temp so not an emergency (yet), but is this normal? LEDs don't show any error codes- Sticker on door says 'Normal/fan operation' sequence when burners are off; 'Normal heating operation' sequence when burners are on. Filter changed about a month ago and looks fine. Midwest USA. Trying to decide if I need to call someone before holiday.

Thanks!


r/hvacadvice • • 21m ago

Heat Pump Traditional split heat pump defrost just before blower turns off

1 Upvotes

I have a 4T Comfortmaker ducted heat pump. N4H4 series outdoor unit, FEM4X air handler, traditional, non-cold-weather heat pump. When the aux coils turn on, the air handler fan kicks to high speed (tap #4 on the motor) so I can tell when the unit is in defrost mode even if I don't hear the reversing valve engage.

According to the installation manual, the FEM4X air handler has a 90s off-delay for "normal" fan speeds. The upshot being that after the thermostat turns off the outdoor condenser, the indoor fan continues to run for 90s. When operating in high-speed "electric heat" mode, via motor tap #4, the delay is 0s presumably so that once defrost has finished the motor immediately returns to normal speed.

At least once a day I hear the following behavior: when in normal heat pump mode, the fan will ramp up to start a defrost cycle. A few seconds later the fan stops. The next time the thermostat calls for heat (which may be 10-15 minutes later), the unit starts in defrost mode but otherwise proceeds normally. So defrost cycle appears to have been interrupted.

What I think is happening is the unit goes into normal defrost mode which is controlled by a timer on the outdoor condenser (I think mine is set for 60 minutes). A few seconds later, the indoor thermostat stops calling for heat so it turns off the outdoor unit like it normally would. And since the air handler fan's off-delay is 0s when in high speed mode, the indoor fan shuts off immediately also. The next time the outdoor unit comes on, defrost mode is still latched so it resumes defrosting until the coil temperature reaches 65F...

Q1: This is a 4T unit so the indoor coils are probably 15kW. Are there any risks to turning the blower off while the coils are hot?

Q2: When the unit resumes the defrost cycle, it's basically operating in air-conditioning mode. But it's cold outside and the compressor and coils may be cold depending on how much time has passed since the last call for heat. Is there a material difference, as far as risk to the compressor goes, between starting in heat pump mode when cold versus starting in air conditioning mode when cold? Or is six of one, half-dozen of the other?


r/hvacadvice • • 24m ago

Should I add a cold air intake pipe to my high efficiency gas heater?

1 Upvotes

My 1970 constructed 2-story Colonial with full unfinished basement in wintery New York State had a high efficiency gas heater installed a few years ago with only one PVC pipe out the side of the house for exhaust. It has a place to install an intake pipe, but it was not done at install.

I Recently replaced the standard water heater with a high efficiency water heater and also vented it out with PVC pipe. The water heater has a snorkel intake and can only use basement air for intake.

Am I using too much inside air now for proper venting? Should I add an air intake to the furnace now that I have 2 units consuming inside air?


r/hvacadvice • • 47m ago

Am I stupid?

1 Upvotes

We’re starting a kitchen remodel with a 36” induction. All I’ve read online is 400cfm is more than enough for the smoke/grease. We were looking to do a remote fan just to minimize the noise in the kitchen but I can’t find anyone who makes a 42” insert with a remote blower that low cfm. It seems everything is much higher and we’re trying to avoid that so we don’t have to use makeup air. Am I crazy, I can’t seem to find one anywhere!


r/hvacadvice • • 48m ago

Furnace Concerning?

1 Upvotes

We just had this unit repaired after 3 years of it not running. This is the second week but today is the first time this has happened. Is it safe to keep running it like this? I contacted the HVAC company I'm still waiting to hear back from them. 50k btu unit.


r/hvacadvice • • 51m ago

Quotes Advice for adding central AC please

1 Upvotes

Hello,

I just bought a 2000 square foot home. The second floor has central AC but the first floor does not. The house is over a 100 years old.

What are my options? Is a high velocity system on the table? Thinking that the heating ducts aren’t large enough to provide enough for cooling.

Thanks


r/hvacadvice • • 4h ago

Furnace Constant gas/chemical smell coming from vents. Please help!

2 Upvotes

our HVAC tech recently sprayed some solution to kill dirty sock syndrome in our new trane unit. he could t find any mold or any reason for the smell, but it was very strong inside the unit.

we turned on the ac and aired out the house for 3 days straight but the smell from the solution was so strong we had to leave our house during that time. it was affecting our health and giving our toddler breathing problems.

yesterday, the tech removed the coil completely and said he’d replace it with another one that’s been dipped in the solution by the manufacturer. the new coil should arrive in about a week. in the meantime, weve been running the furnace.

every time its on, there is a strong odor that pours through. it’s a mix of a chemical smell (different from the solution) and the gas smell of the furnace turning on. but it’s persistent. he removed the coil at 4pm and at 5am it still smells very very strong. we don’t feel ill, but it’s still concerning.

when he first turned the furnace on after removing the coil, we told him it still smells and he said “if it still smells then I have no idea what it could be bc I removed the coil” and then left.

is this normal?? should we still be smelling some kind of output 13 hours after he removed the coil?

our air purifiers are all stuck at 25 for air quality (25 is moderate air quality, 50 is highest it goes) but when we open a window it drops to 5, so something is definitely in the air. Our CO monitor says 0


r/hvacadvice • • 1h ago

Water cooler hot water dispenser

0 Upvotes

My office Avalon water cooler model #A7BOTTLELESSBLK will not dispense hot water I have already troubleshoot - checked the cold water tank and check for ice build up


r/hvacadvice • • 1h ago

Quotes 🚨Help ASAP Pls

0 Upvotes

I live in Nashville TN and scheduled The Clean Air Company to clean all the vents in my house because Cumberland Cooling is going to be installing a new HVAC system next week. The HVAC has been struggling for 2+years. FOR SURE the Vents have not been cleaned since 1999 - possibly never! Cumberland recommended The Clean Air Co (AFTER I bought the idea up - they did NOT recommend it or try to upsale or push it on me).

Now I've been reading how vent cleaning (besides the dryer vent) is not necessary ever.

Should I ask if they use a camera to determine IF each vent needs cleaning?

I have 2 dogs mostly hypo allergenic - cavaliers = low shed. Here's the quote what do y'all think?:

Air Duct Cleaning Base
Service

Cleaning and sanitizing of up to 10 air duct openings (vents/registers & returns combined)
$595

Plus Additional air duct openings are $25 each.

Also what does "vents/registers and returns combined" mean?

💖Love this community - Grateful for all well informed / real life experienced opnions💖


r/hvacadvice • • 1h ago

Boiler System Design

Post image
1 Upvotes

Do you see any issues with this layout?
planning on replacing electric baseboards with hydronic in the next couple years and want to put pex in the walls as i'm renovating now. That I can tie into later once I have half of the rooms or so renovated.

The goal is individually controlled rooms that can be monitored from a central dashboard.
propane being the most cost effective where I live.

Will be using Wall panel rads with individual smart control valves on them. So any recommendations on those would be great.

Thanks.


r/hvacadvice • • 1h ago

Recommendations Please

Post image
1 Upvotes

I tried posting this before and got some snark and mostly unhelpful feedback. I am hopeful that if I explain the situation more clearly, I might get some better advice.

My heat shuts off before hitting the desired temp. See pic. It doesn’t matter what my thermostat is set to. (Please don’t tell me to just turn it up. That makes no difference.) I also noticed the ac doing the same thing this summer but it wasn’t as frequent as it was a pretty mild summer so cooling the house wasn’t that hard.

Here’s what we’ve done so far: we change the filters every three months minimum. We replaced the thermostat last year. My husband cleaned the flame sensor last year. I checked intake vents in the rooms and ensured none were blocked by furniture or anything.

If it was running constantly I’d assume something with insulation or a leak somewhere, but that’s not what’s happening. For more info, there is a switch on the wall that supplies power to the furnace. If I switch it off and turn it on again, the furnace comes on for a while.

Much colder weather is coming and I’m not looking forward to worrying about this all winter. Every time we have a service person come in they want to replace everything at 2x the national average cost (like quoting $6k for a simple water softener replacement) so I’d like to exhaust my diy options.


r/hvacadvice • • 2h ago

General Heater rattle noise!!!

Thumbnail
gallery
1 Upvotes

Something is rattling, heater IS working though. Any suggestions as what it could be? I’m all for calling someone to look at it but was wondering if anyone had a possible idea if a non-hvac/new homeowner could fix the issue, if it’s just a part replacement or something simple of course. I supplied pics of my unit and what I believe is rattling, I couldn’t upload a video. There was also a part the previous owners left in there, which I have no idea what it is and supplied those in case it helps. Thanks in advance!!


r/hvacadvice • • 21h ago

Running duct above non-structural wall?

Thumbnail
gallery
35 Upvotes

I'm building out a soft story into livable space. We have a big I-beam above this wall that separates rooms, and need to run ducts somewhere. I'd like to avoid a soffit and came up with this idea to shorted the stud wall and run the duct along the top of it.

Is this dumb?


r/hvacadvice • • 2h ago

General Switching from forced air oil to gas. What am I looking at?

1 Upvotes

We are looking into buying a home that has forced hot air oil as the primary heating source. The oil tank is over 30 years old and the furnace itself appears newer, but it’s at least 15 years old.

There is natural gas in the neighborhood, it appears this in the only home that did not hook up to that gas when the service was installed on the street.

Im wondering if the fact that this is already forced air, and has ductwork, will make this any less painful.

Im not opposed to propane, which I have at my current property, with a buried tank. I feel like that’s worked out well, and the price of propane has been much more stable than oil.

Its a holiday week and I’m having a tough time hearing back from any local contractors.

Is there a ballpark number that we could be looking at? I have no interest in replacing the oil tank and keeping oil, so if this can’t be done at a price that is palatable to us, we’ll walk from the house. Because I know the oil tank, at minimum, needs replacement soon.

Ive gotten various answers on specific Parts. Meaning, sometimes the utility will pay for line installation To the property from the street if you will be a gas customer, and sometimes they won’t. Really seems to be a case by case basis.


r/hvacadvice • • 2h ago

Clicky ductwork

1 Upvotes

I have some vents that make a clicking noise. They are in a crawlspace. I'm thinking the temp difference is causing the metal to flex back and forth and makes a metal flexing click every 20 seconds or so. What could I do to fix this?


r/hvacadvice • • 8h ago

2023 Bryant furnace short cycling

3 Upvotes

I’ve had two techs say my furnace is oversized and causing issues. Before I go buy a new smaller furnace I wanted to check that it all adds up. I do believe my furnace is oversized but is it actually causing the issues I’m not sure.

Furnace: Bryant 915SB48080E17 (80k BTU input, single stage, 96% AFUE), installed horizontally in the attic

2025: tech replaced the limit switch
2026: tech replaced dual pressure switch

Could an oversized furnace cause the dual pressure switch to fail?

Could failing to change out 1 inch merv 11 filter for a year cause these issues?

One guy quoted me 15-20k to replace it. Seems very high to me. Is that the going rate anywhere in the west coast United States?


r/hvacadvice • • 2h ago

Boroscope recs

1 Upvotes

I am possibly looking for an articulating boroscope to add to my tool arsenal. How useful and how often do you use it. Not looking to spend more then $250. Im thinking one could use to look at coils and heat exchangers. It could also be used to look for leaks in walls after drilling small hole. Any other good uses?


r/hvacadvice • • 3h ago

Mid 2000s Tappan

Thumbnail
gallery
0 Upvotes

What exactly am I looking at here? Tappan Furnace


r/hvacadvice • • 3h ago

Replacement quote

Post image
0 Upvotes

Does this seem high for piedmont NC?