Do you see any issues with this layout? planning on replacing electric baseboards with hydronic in the next couple years and want to put pex in the walls as i'm renovating now. That I can tie into later once I have half of the rooms or so renovated.
The goal is individually controlled rooms that can be monitored from a central dashboard. propane being the most cost effective where I live.
Will be using Wall panel rads with individual smart control valves on them. So any recommendations on those would be great.
I tried posting this before and got some snark and mostly unhelpful feedback. I am hopeful that if I explain the situation more clearly, I might get some better advice.
My heat shuts off before hitting the desired temp. See pic. It doesn’t matter what my thermostat is set to. (Please don’t tell me to just turn it up. That makes no difference.) I also noticed the ac doing the same thing this summer but it wasn’t as frequent as it was a pretty mild summer so cooling the house wasn’t that hard.
Here’s what we’ve done so far: we change the filters every three months minimum. We replaced the thermostat last year. My husband cleaned the flame sensor last year. I checked intake vents in the rooms and ensured none were blocked by furniture or anything.
If it was running constantly I’d assume something with insulation or a leak somewhere, but that’s not what’s happening. For more info, there is a switch on the wall that supplies power to the furnace. If I switch it off and turn it on again, the furnace comes on for a while.
Much colder weather is coming and I’m not looking forward to worrying about this all winter. Every time we have a service person come in they want to replace everything at 2x the national average cost (like quoting $6k for a simple water softener replacement) so I’d like to exhaust my diy options.
Something is rattling, heater IS working though. Any suggestions as what it could be? I’m all for calling someone to look at it but was wondering if anyone had a possible idea if a non-hvac/new homeowner could fix the issue, if it’s just a part replacement or something simple of course. I supplied pics of my unit and what I believe is rattling, I couldn’t upload a video. There was also a part the previous owners left in there, which I have no idea what it is and supplied those in case it helps. Thanks in advance!!
We are looking into buying a home that has forced hot air oil as the primary heating source. The oil tank is over 30 years old and the furnace itself appears newer, but it’s at least 15 years old.
There is natural gas in the neighborhood, it appears this in the only home that did not hook up to that gas when the service was installed on the street.
Im wondering if the fact that this is already forced air, and has ductwork, will make this any less painful.
Im not opposed to propane, which I have at my current property, with a buried tank. I feel like that’s worked out well, and the price of propane has been much more stable than oil.
Its a holiday week and I’m having a tough time hearing back from any local contractors.
Is there a ballpark number that we could be looking at? I have no interest in replacing the oil tank and keeping oil, so if this can’t be done at a price that is palatable to us, we’ll walk from the house. Because I know the oil tank, at minimum, needs replacement soon.
Ive gotten various answers on specific Parts. Meaning, sometimes the utility will pay for line installation To the property from the street if you will be a gas customer, and sometimes they won’t. Really seems to be a case by case basis.
I have some vents that make a clicking noise. They are in a crawlspace. I'm thinking the temp difference is causing the metal to flex back and forth and makes a metal flexing click every 20 seconds or so. What could I do to fix this?
I am possibly looking for an articulating boroscope to add to my tool arsenal. How useful and how often do you use it. Not looking to spend more then $250. Im thinking one could use to look at coils and heat exchangers. It could also be used to look for leaks in walls after drilling small hole. Any other good uses?
our HVAC tech recently sprayed some solution to kill dirty sock syndrome in our new trane unit. he could t find any mold or any reason for the smell, but it was very strong inside the unit.
we turned on the ac and aired out the house for 3 days straight but the smell from the solution was so strong we had to leave our house during that time. it was affecting our health and giving our toddler breathing problems.
yesterday, the tech removed the coil completely and said he’d replace it with another one that’s been dipped in the solution by the manufacturer. the new coil should arrive in about a week. in the meantime, weve been running the furnace.
every time its on, there is a strong odor that pours through. it’s a mix of a chemical smell (different from the solution) and the gas smell of the furnace turning on. but it’s persistent. he removed the coil at 4pm and at 5am it still smells very very strong. we don’t feel ill, but it’s still concerning.
when he first turned the furnace on after removing the coil, we told him it still smells and he said “if it still smells then I have no idea what it could be bc I removed the coil” and then left.
is this normal?? should we still be smelling some kind of output 13 hours after he removed the coil?
our air purifiers are all stuck at 25 for air quality (25 is moderate air quality, 50 is highest it goes) but when we open a window it drops to 5, so something is definitely in the air. Our CO monitor says 0
I heard something rattling in the wall so I went to check the filter and I see this? A bunch of bits of random paper and trash? My first thought is rats. wtf is going on?
I’ve had two techs say my furnace is oversized and causing issues. Before I go buy a new smaller furnace I wanted to check that it all adds up. I do believe my furnace is oversized but is it actually causing the issues I’m not sure.
Furnace: Bryant 915SB48080E17 (80k BTU input, single stage, 96% AFUE), installed horizontally in the attic
Brand new furnace model ML180DF070E36AK Merit Series Single Stage Heat ECM Blower. Has a red LED light that blinks once per second with no gaps. I've tried reading the manual and found no reference to this sort of code, only codes that were a certain number of red light blinks.
Does anyone know what this is? Should I get in contact with the installers? The red light shines through a window so it's very obvious and seems to indicate a fault, I just don't know what.
I am not familiar with this stuff at all so I need some guidance. I had to replace my microwave and after taking the exhaust duct stuff out since it was filled with smoke and grease, I’ve installed the new microwave but I don’t know how to connect these to ends to exhaust from my microwave over the stove.
The rectangle to circle doesn’t work because they are to close together nothing fits, and the 90 degree circle duct doesn’t turn sharp enough so it doesn’t work.
So here’s what it looks like and I was thinking about doing this box setup my sister in law has but I have no idea how to create this and install it. Do I need some custom hvac solution?
Our Lennox cooling system compressor has died and we have been told to replace the whole system. It is an add-on to the Braemar ducted heating. Has anyone had any luck replacing the lennox and keeping the Braemar?
Lived in this apartment for a little over a year. When we moved in the central ac was broken. Technician refilled the coolant and the problem was fixed for a while, then every couple months the same thing would happen. A week ago the air stopped blowing completely, recharged the coolant and it worked for a few hours. Tech came back and said the compressor was broken. New tech came and replaced the entire system, even the thermostat. Worked for a few hours. Won’t blow at all now.
The outlet on the other side of the wall with the thermostat is no longer giving power to my lamp, but the thermostat still reads the same as if it were on. Is this a wiring/ electrical issue? I don’t want to have them fix it again to only have cold air for a few hours.
I'm looking to replace a standard thermostat for a Carrier Infinity 98 gas furnace paired with a Carrier Performance two-stage heat pump with the Infinity System Control. We currently have a RedLink thermostat, but I would like to upgrade to the Infinity System Control SYSTXCCWIC01-C thermostat to take better advantage of the Infinity furnace.
There are only 2 wires running to the existing thermostat location and no easy way to replace that, which is why we are using RedLink. I would like to install the Infinity System Control right by the furnace, then use the 2 existing wires for a remote temperature sensor.
What I am not 100% clear on is if the SYSTXCCWIC01-C supports this configuration. I've read that the -C model requires an additional zone board for zones, but I have received conflicting information on if the -C model has the S1 and S2 terminals for a single remote sensor without zones or a zone board. I don't need humidity, I only need temperature and for the remote sensor to be the primary sensor. On page 52 of the install manual it seems to indicate you can connect it to ZS1 and ZS1C, however nowhere else in any wiring diagrams does ZS1 or ZS1C show up.
I'm trying to figure out first if this is even possible, and second exactly which components I need to purchase. The furnace will be a "communicating" furnace, and the two-stage heat pump is "non-communicating".
Assuming the terminals are still there for the -C model, I believe I need the following:
SYSTXCCWIC01-C wired directly to the furnace ABCD connection
SYSTXCCRRS01 connected to the SYSTXCCWIC01-C via ZS1 and ZS1C
TSTATXXSEN01-B for the outdoor temperature sensor
SYSTXCCNIM01 NIM connected betwen ABCD and the outdoor heat pump C R O Y2 Y
Assuming ZS1 and ZS1C do exist, I should be able to have the thermostat at the furnace, and utilize the remote sensor to actually determine when temperature has been reached. The Infinity controller would control the gas furnace and air speed directly, and would control heat/cool from, and stage of the heat pump via the NIM. I would also be able to control that remotely via the app.
Is anyone able to verify that the -C model actually has the terminals for the remote sensor and would work in this way?
Edit: The main unit will be in the conditioned space, but not the best space for the temperature sensing.
I just flipped the breaker to our boiler as suggested in the instructions and switched the heat only non-programmable thermostat for the old broken mercury dial. When I flipped the breaker back on and came inside, the boiler fired back up after a minute or two and two or of our five areas came back on but not the other 3 including the area the new therm was installed in. The boiler has tried to fire up a couple times since but flips off. I was going to reinstall the old unit to see if the other units will kick back on. The bottom right valve is for area that I changed the thermostat on. Curious if anyone has any insights while I reinstall the old broken thermostat. EDIT: SWITCH WAS ONLY FLIPPED OFF AFTER THE AREA FAILED TO COME ON
Hi! I’m a renter and landlord recently installed Bryant mini-splits (in Massachusetts). Ive noticed when I turn it on for hearing, my wall unit doesn‘t seem to “trigger” any air and nothing comes out. I’ve tried waiting upwards of 30 minutes, and it doesn’t seem to start blowing unless I turn up the temp up to like 71, at which point it starts blowing after a while. That doesnt really bother me, but I want to make sure it’s not a sign of a bigger issue.
Also, is it normal for it to constantly be blowing air (doesn’t seem to stop even when temp is reached)? I’ve had mitsubishi mini splits, which would periodically stop blowing air and the vanes would turn back upwards. These bryant ones seem to blow even when in the upwards position. I’m just worried it’s excessively using electricity
TIA for answers! I don’t know much about hvac 😅 Im mostly wondering if they’re all a little finicky or if I should ask for landlord to sent a tech to check it out
I’m a homeowner with limited HVAC experience, trying to learn and troubleshoot methodically. I have clamp-on temperature probes, an R410A-compatible refrigerant manifold gauge set, a water-pressure gauge for the ground-loop P/T ports, and a multimeter. Those are the tools I’ve been using to collect the readings below. I’d appreciate explanations in plain language and guidance on which measurements would be most useful next.
I’m troubleshooting weak heating from a geothermal heat pump. The compressor, blower, and both ground-loop pumps are running, but the supply air is barely warmer than the return.
Equipment and configuration:
Bosch/FHP CE061-1VTN-FLT-AB, R410A, one compressor with two capacity stages.
Honeywell HZ322 zone panel with three Ecobee thermostats.
Panel configured for a two-stage heat pump during testing; emergency heat off and compressor operating in stage 2. Y2 has been verified at approximately 25 VAC at the unit.
Geo-Flo flow center with two Grundfos UPS 26-99 F pumps, both running on medium speed.
Sporlan BBIZE-8-GA-B20 TXV, customer part 850-055.
Bidirectional filter-drier, FDBF-165S-P, part 860-006.
Representative stage-2 heating readings, collected sequentially during steady operation:
Refrigerant readings
Suction pressure: 85 PSIG
Discharge pressure: 236 PSIG
Suction-pipe temperature beside TXV sensing bulb: 68°F
Calculated suction saturation temperature: approximately 24°F
Calculated superheat: approximately 44°F
Air temperatures
Return-air reference: 66°F
Discharge-air temperature sensor (DATS): 73°F
Air temperature rise: approximately 7°F
Ground-loop water readings
Bottom connection temperature: 63.3°F
Top connection temperature: 62.4°F
Bottom port pressure: 8–9 PSI
Top port pressure: approximately 2 PSI
The pressure readings suggest water enters at the bottom and exits at the top. That gives approximately 0.9°F water temperature drop and 6–7 PSI water pressure drop. Water temperatures were measured with the same clamp on bare metal fittings near the unit; actual GPM and antifreeze concentration haven’t been verified.
Other observations:
The compressor discharge pipe has measured approximately 147°F, but only the middle portion of the air coil feels warm.
Hand-warming the attached TXV bulb from approximately 68°F to 76°F produced little suction-pressure change—approximately 85–86 PSI.
Electric emergency heat works and has produced DATS readings around
100F
. Replacing the two electric-heater contactors eliminated loud chattering.
No TXV adjustment was completed.
Do the pre-release readings point more toward inadequate refrigerant feed/TXV trouble or a water-side heat-transfer problem? What measurements would best distinguish those before replacing parts?
I am a g1 tech in ontario and doing good i love wht i do but i have got an opportunity to go into local ua union but i will be starting at a low wage or as junior mechanic I dont know wht should i consider
I know I’m going to get some comments about static pressure, but I’m trying to see ideas on a solution and I’ll be doing some measurements after I install it.
I have a 12”x6” register directly in the side of my duct (maybe 12x12 duct board trunk, I didn’t measure it exactly). It blows directly in the room. That room gets way colder and the downstream of the trunk never gets enough. When I close the register a bit to reduce the flow just a little it gets really loud in the room. The main duct is in between the ceiling joists of a 3-story house so I can’t add a damper anywhere.
Is there a different register I should try or do I need to cut a reducing plate with a hole and place it in the opening? Any ideas I’m not thinking of?