r/hvacadvice • • 30m ago

I don’t know where this sound is coming from

4 Upvotes

It sounds like it’s coming from inside the boiler. I replaced the inducer fan 1.5 years ago and it doesn’t sound like it’s coming from there. I know the boiler is very old but I want to at least make it through this winter with it.


r/hvacadvice • • 1h ago

General Pipe in my attic, could I route bathroom vent through it?

Post image
3 Upvotes

Bathroom is super steamy and has no fan for steam. I want to install one, wondering if this pipe could be used for that? It seems like an unused vent to the roof to me. But alas I am a simple fool. Looking for advice. Tired of mitigating bits of mold on bathroom ceiling.


r/hvacadvice • • 6m ago

Furnace Furnace Exhaust Motor Replacement

Thumbnail
gallery
2 Upvotes

My furnace exhaust motor seems to be on its way out. The furnace will randomly turn off throughout the day or night, and from what I understand it's due to the exhaust motor not turning on quickly enough and giving the signal in time that it's working.

If I hand rotate the motor a few times, it'll work. I can get anywhere from 2-6 hours average, and then it'll need to be done again.

It looks pretty simple to replace, but I can't seem to find a replacement for it.

If anyone knows where to go to find this, I'd appreciate the help!

I'm trying to stay on a tight budget. I was hit by a car a few days ago, so taking some time off work while recovering, and it doesn't make me want to go pay a technician and their rate on parts at this time.

My furnace is a Payne PG92SBS48060B, from 2014.


r/hvacadvice • • 22m ago

HVAC unit

2 Upvotes

We’re getting a new house and it currently have forced air ac in the attic but no forced air heat. The heat is a baseboard boiler system. We plan to renovate quite a bit of the house so we’re planning to get rid of the baseboard.

So my question is what’s the best furnace & potentially ac unit to go with? I don’t need or want the maximum efficiency unit. I want a good, reliable and affordable unit that’s easy to source parts and reasonably priced parts.
I’m kind of leaning towards a Goodman as they’re just super simple designed and they’re now backed by Daikin if I’m not mistaken.


r/hvacadvice • • 39m ago

Loud steam radiator system is shooting dark water from valve

Post image
2 Upvotes

One of my steam radiators is releasing a lot of dark brown water when it runs. The pipes are also banging a LOT compared to previous winters. They're so loud it's hard to sleep at night when the heat kicks in.

I know boilers sometimes have rust or some sort of corroded metal in them, but I'm surprised it's made its way up the pipes?

Sorry for the bad screenshot of a video, but it shows the water shooting out the top and a drip spot below.


r/hvacadvice • • 8h ago

Furnace Update: goodman 95% no gas - problem found!

Post image
8 Upvotes

Thanks to the help I got here https://www.reddit.com/r/hvacadvice/s/tgRYTyKhbp and from a helpful tech who didn't have time to visit but volunteered to sms me through some things, I think I've found the problem. This front cover pressure switch wasn't closing.

I'd jumpered across the nodes on the switch, held down to the cover switch, and presto! Flame! This completely explains why the problem happened occasionally last year, and frequently now.

UPDATE - I removed the switch, put a multimeter across the terminals, and gently sucked on the hose to make it click. The switch remained open the whole time. It's 100% a bad switch. I would happily replace myself, but I already has a tech on the way. I callee them ahead of time so they could source the right part for me. Figure it's worth the $100 to have them install it, deliver the part, and do a once over to make sure it's otherwise in good working order.

Thanks in advance - you folks were great last time!


r/hvacadvice • • 1h ago

Rheem furnace showing H22 and 57 codes.

2 Upvotes

Hello! I have a Rheem furnace model R92PA1001521MSA and can not get the furnace to ignite. I have replaced the integrated furnace control board and done all of the troubleshooting I can think of. I have tested everything and there is no obvious issues but the furnace keeps throwing out the 22 and 57 codes. I have cleaned everything, replaced the filter, checked all of the electrical connections and everything looks good but it will not ignite at all. I ordered 2 control boards from Supply House and the first one had obvious damage so I sent for a replacement part. Upon receiving the second one it looked like every box in the UPS truck had been stacked upon my little box which had one deflated air pillow inside. Some of the connections were flattened and bent but it did not appear to be disconnected and all of the welds looked in tact. So I did swap out for the second board but am still getting codes for limit switch open and high pressure open. I don't know what my next steps should be or what parts I should swap out next. All I know is it is 51 degrees in here and it is getting extremely uncomfortable to say the least. Help! Any suggestions?!? Thank you!


r/hvacadvice • • 2h ago

Lennox C33-25B-2-6 drain trap leaking

Thumbnail
gallery
2 Upvotes

I noticed the condensation drain trap was leaking, so I bought a new replacement piece (part # 103429-01), and it's leaking from the exact same area. Part of me doesn't think this was installed correctly, because with the way it's hooked up now, all the water just sits at the bottom instead of draining out. (I can see through the open portion at the top all the water is just sitting down there). I would greatly appreciate any help/advice.


r/hvacadvice • • 10h ago

Options for quieting air return?

Thumbnail
gallery
8 Upvotes

Ignore the jungle canopy. Not actually touching the grille. HVAC unit on the other side of the wall, in the door in the 2nd photo.

Looking for options to quiet the return without poorly impacting pressure/performance. Already going with foam insert sound dampeners in the floor ducts. So not looking for any super involved work if it can be avoided (limited tools in the house)

Any advice is appreciated!


r/hvacadvice • • 3h ago

Filters Filter Questions?

Thumbnail
gallery
2 Upvotes

So I have a main air handler in my basement and a lay down unit in my attic. House is all electric for heating and cooling (heat pump) and these are the two filters on the units I was able to locate. My question is are these the only two filters?? How often should I be changing ones of this size?? These are the ones installed by the HVAC company who did my install so should I stick with these filters or is there a better brand? Also I know there’s different levels of filtration and I’ve heard going to high chokes the system but too low lets debris in. What’s the happy middle ground? Links or pics are much appreciated. I’m a brand new homeowner just trying to do things properly and take care of my house.


r/hvacadvice • • 3h ago

Boiler Natural gas boiler thermostat

Thumbnail
gallery
2 Upvotes

Hello all. I’m trying to get the natural gas boiler in to light for actual heat. I have successfully lit the pilot but the unit will not fire off to make heat. There is power to the unit but I found a set of wires not attached to a terminal under the power switch. I’ll post photos of everything as it sits currently. I think the issue may be with the spaded wires that are right near a terminal block that looks like they should attach to it. Any advice would be greatly appreciated as this is my 3rd house I’ve owned and never had to deal with a boiler system.


r/hvacadvice • • 5h ago

General Anyone know how to date this old carrier SN?

Post image
3 Upvotes

The blower assembly is shot and I want to tell the customer it's not worth investing into a repair. Even if I could get the parts.


r/hvacadvice • • 1m ago

Carrier 59SC5 intermittent raw fumes/exhaust

Thumbnail
gallery
1 Upvotes

Hey

Need help with this one. Had an intermittent gas smell which felt like a backdraft issue from the exhaust to intake pipe. I smelled directly fumes from the intake port in the furnace. I temporarily created another 6 feet pipe to diagnose the issue. It went away for about a month. The furnace is constantly on, I have my clothes near the furnace so I notice it if when I do smell it. Yesterday was a windy day, I’m wondering if it’s possible Again a backdraft issue, but possibly on the exhaust side now (from height now with more wind exposure) or possibly a leaking mixing/shut off valve. I was wondering to be the gas directly meter (Amazon 60 bucks) but it’s so intermittent. I did a bubble spray on the lines to see if leaks are present which it isn’t. It’s so intermittent that I think it’s a leaking valve now.

Any ideas?


r/hvacadvice • • 17m ago

What is wrong with my furnace and should I turn it off right now?

1 Upvotes

My furnace suddenly started making awful noises about 30 min ago. It's going below freezing tonight. Should I turn it off and set up some space heaters overnight? Since it's a holiday week, I don't know when I can get a service person over.


r/hvacadvice • • 31m ago

Popping/bang noise when heat cycles off

1 Upvotes

Hello I have a Goodman 95% furnace and I’m hearing a bang or a knock or a pop when the heat turns off any ideas why?


r/hvacadvice • • 4h ago

Noise coming from boiler

2 Upvotes

Husband I got home from work, suddenly heard an awful noise and it didn’t take long to realize it was coming from basement/boiler room. We do not know much about boilers, have been in our new house for roughly 2 years and have never had to mess with it. Noise is coming from the first pump in the video, which last year we noticed a small puddle of (water?) below the pump, only very small amount. I’m assuming the pump is going bad, house is built in the 70’s and everything is original here I am assuming. Any insight on what steps to take? Obviously call someone- but is this an easy fix for savvy people lol, should I shut the heat off until this is fixed? We have mini splits we can run in the mean time if needed. Thanks!


r/hvacadvice • • 43m ago

Garage Reznor LUS-50-F

Post image
1 Upvotes

Recently bought a house where the original owner was a carpenter with a wood shop attached to the garage. Installed is this Reznor LUS-50-F. I’ve confirmed power and have gas flow. Prior to attempting to fire up, I’m trying to decide if it’s worth disassembling and cleaning out as it doesn’t appear to have run in a few years. Any advice is appreciated.


r/hvacadvice • • 55m ago

Very weird Goodman furnace issue

1 Upvotes

The Goodman furnace in my apartment won’t work consistently. It was new 5 years ago when I moved in and never worked properly. Landlord did the install himself with the help of a handyman, and has made
Two attempts to send people to fix it.

Their words were ‘yeah we can see it doesn’t work sometimes but we don’t know what’s wrong’
Landlord just says use a space heater he provided when it’s not working right. No I will not be reporting him because otherwise it’s very nice to live here and inexpensive.

The problem is very odd The inducer runs and the ignitor glows nice and hot. Sometimes the gas valve opens and the furnace works as it should.

Other times the gas valve will just click once or twice; sometimes it will even rapid fire click like 1-2 times a second. The spookiest one is does is it will ignite and the flame will sputter on and off a few times before failing entirely.

Sometimes the ignitor will glow, and the gas valve won’t even click on and it will do the whole inducer cycle again, and no click from gas valve, and so on until it gives up after the 3rd attempt and times out for however long.

I already cleaned the flame sensor once, and when that didn’t work I replaced it. I’m handy with tools but not an hvac tech so don’t flame me too hard.

The only codes I’ve seen it flash were system lockout.


r/hvacadvice • • 1h ago

With a whole-house dehumidifier, single-stage, two-stage or variable-speed AC?

1 Upvotes

First-time OP here. I live in Houston in an old, semi-leaky house. I am prepping to replace my very old, poorly designed HVAC system in conjunction with insulation and roofing work. I've identified a knowledgeable contractor and got his recommendations today. I want yours. With installation of a whole-house dehumidifier, is a single-stage AC unit sufficient? Is a variable-speed AC overkill? Would a two-stage be a nice middle ground? Thank you.


r/hvacadvice • • 4h ago

General 33 M with a family pretty much starting from zero

2 Upvotes

Long story short I got let go from my help desk position and have been struggling to find a stable job for the past six months. Switched over to IT from security guard work 3 years ago, now it's looking like I have to switch careers again.

I found a post on Craigslist of a guy looking for techs and I texted him if he's willing to bring someone on with no experience, which he seems like he's willing to. I'm expecting to get paid minimum wage if he does decide to bring me on, which sucks but it is what it is.

If this does go through what kind of work should I expect to be doing as someone going in blind?

Thanks in advance.


r/hvacadvice • • 1h ago

Honeywell MZV520-RP, Home heating crisis

Post image
1 Upvotes

I have a zoned hot-water heating system with Honeywell MZV PowerTrack motorized zone valves (MZV526E-T, 1" NPT) on a multi-zone manifold. One valve's actuator head appears to have failed, so that zone no longer heats properly when its thermostat calls. The valve body seems fine, so I only want to replace the head. The existing heads are 24 VAC, 0.25 A, 4-wire (2 yellow motor wires, 2 red end-switch wires), normally closed, rack-and-pinion, and mount with a knurled brass nut on a 30 mm collar. The Honeywell replacement head (MZV520-RP) was discontinued in 2020. I've read that the Wirsbo/Uponor A3020522 motorized valve actuator is the same Sparco-made head under another label, and it's still available new-old-stock on eBay.
Will the Wirsbo/Uponor A3020522 fit and work on my Honeywell MZV valve body as a direct replacement, or is there a better option I should consider? Thanks to all


r/hvacadvice • • 5h ago

Furnace Small duct problem

Thumbnail
gallery
2 Upvotes

The lowest MERV that fits my system is 11. What do I do? It has been a problem for sure. For AC, it is fine. But for heat, it adds to small duct issue over heating on very cold days and in mornings. (I stopped using MERV 13 years ago.)


r/hvacadvice • • 1h ago

Furnace help

1 Upvotes

Hi, everyone! I'm not a licensed HVAC professional, but I do own my own home improvement business. My furnace went out a couple of days ago and I had a HVAC tech come and take a look.

My furnace is running through the cycles with the LED light on the circuit board staying on (constant), but there's a click sound coming from the gas valve. The igniter burns orange, but fails to light the burners. The tech said that my inducer motor was at the end of its life and needed replaced, which would fix the issue. However, he wanted $2,200 to replace that. I did it myself. The furnace still cycles the same as before and fails at the lighting burners point.

I've replaced the inducer motor/assembly, both transformers, the main circuit board, and cleaned out all lines and reservoir. Still cycles the same. The VAC to the gas valve is reading very low (.29 & 1.5 at the time it clicks). Do you think a new gas-valve is the next step?

Equipment:
GOODMAN Model # GK890453BXAF
Honeywell Gas-Valve Model # VR8215S1214


r/hvacadvice • • 1h ago

Carrier Comfort 80 – Intermittent Cold-Start Ignition Failure, New OEM Flame Sensor, HVAC Tech Unable to Diagnose

1 Upvotes

Carrier Comfort 80 – Intermittent Cold-Start Ignition Failure, New OEM Flame Sensor, HVAC Tech Unable to Diagnose

I am looking for some technical insight from experienced HVAC technicians or anyone who has encountered a similar issue with a Carrier furnace.

Equipment information:

  • Manufacturer: Carrier
  • Series: Comfort 80
  • Model: 58SC0A045E141212
  • Manufactured: 2022
  • Thermostat: Google Nest
  • Replacement flame sensor: Carrier OEM LH680534
  • Location: West Tennessee

Description of the problem:

My furnace has developed an intermittent ignition problem that is particularly noticeable after the unit has been sitting idle for several hours, especially overnight.

When the thermostat calls for heat in the morning, the furnace attempts to start but sometimes fails to ignite. Other times, the burners appear to ignite for approximately 2–5 seconds before shutting off. The furnace may cycle through several attempts before successfully starting or eventually stop attempting altogether.

Once the furnace successfully starts, it generally heats the home normally. However, intermittent ignition failures can still occur during subsequent heating cycles.

Troubleshooting history:

  • November 18: Removed and cleaned the original flame sensor. The furnace temporarily returned to normal operation.
  • The intermittent ignition problem returned.
  • Purchased a genuine Carrier LH680534 flame sensor directly from Carrier Enterprise. The dealer verified the correct part using my model and serial number.
  • Installed the replacement sensor, which was physically identical to the original.
  • The furnace operated perfectly for several days, consistently igniting on the first attempt.
  • The problem subsequently returned on three consecutive cool mornings.
  • Power cycling the furnace sometimes restores operation, although it may still fail on its first attempt before eventually starting.
  • The diagnostic LED is now flashing during unsuccessful starts.

Professional HVAC service visit:

The HVAC company that originally installed the furnace came out on November 24.

Unfortunately, the furnace operated perfectly during the entire service visit, which made reproducing the failure difficult.

The technician performed general checks and checked the voltage at the gas valve during the ignition sequence. It did show above 24v at the time at 27v. He explained that the diagnostic code could be associated with several different components or conditions. However, he was unable to determine the cause of the intermittent failure.

I paid for the service call but unfortunately still do not have a diagnosis.

Additional observation:

During earlier troubleshooting, I heard brief motor activity while the Nest thermostat displayed OFF. The furnace may have previously been in ignition lockout. I immediately disconnected power before determining whether it was attempting to ignite. This has not been confirmed as an actual ignition attempt.

My questions:

  1. Has anyone experienced this specific intermittent ignition problem with the Carrier 58SC0A series?
  2. Could a gas valve intermittently fail to open after sitting idle for several hours but operate normally once the furnace has warmed up?
  3. Could a failing control-board relay produce this behavior?
  4. Are there any known Carrier technical service bulletins addressing ignition problems with this model?
  5. What diagnostic measurements would you recommend a technician capture during an actual failed cold-start attempt?
  6. Is there a reliable way for a qualified technician to isolate the issue when the furnace operates normally during service visits?

I have three videos documenting the issue:

  • Failed ignition attempts followed by successful startup after power cycling.
  • Failed startup with the diagnostic LED flashing.
  • HVAC technician inspecting and testing the furnace during normal operation.

I would appreciate any technical insight before paying for another service visit or replacing additional components unnecessarily.

Thank you.