r/hvacadvice • u/Fun_Stand2454 • 8h ago
Contractor accidentally cut mini split wire
Can anyone tell me how serious this is? And is it capable to splice back together? Thanks in advance
r/hvacadvice • u/Fun_Stand2454 • 8h ago
Can anyone tell me how serious this is? And is it capable to splice back together? Thanks in advance
r/hvacadvice • u/jetspwn • 6h ago
**Edited for completeness. Including the readings and estimates in the message body that didn't get submitted the first time**
Hey everyone,
I requested a tune-up on my 2017 2-stage gas furnace (F9MVE0801716A3) in Southwest Ohio. I didn't see any symptoms, holding 70°F fine. I wasn't home for the tune up and my wife wasn't very helpful explaining why the tech left us with three estimates totaling ~$3,600. I'd appreciate a quick sanity check on whether anything here is actually urgent and if it is reasonable.
Tech's readings:
Delta T: 35°F on low fire / 53°F on high fire (rating plate specifies 30–60°F / 40–70°F)
Manifold gas pressure: 1.8" WC low fire / 3.4" WC high fire (specification is 1.3–1.7 / 3.2–3.8)
Flue CO: Approximately 64 ppm (not sure whether raw or air-free)
Flame sensor: 1.1 µA before cleaning, 1.7 µA afterward
Indoor humidity: Approximately 47% RH, although the Fieldpiece screenshots appear to have the probes mislabeled/swapped
Recommendations/estimates:
$849 – Ignition repair: Replace flame sensor and hot-surface igniter and clean burners. The technician described the burners as heavily rusted and the igniter as having heat-stress marks, although it reportedly tested within range. I wasn't provided a photo of the igniter.
$1,149 – UV air purification system: Replace the existing UV system because it's no longer working. I have a spare bulb that I haven't tested yet.
$1,600 – AprilAire fan-powered humidifier: Recommended because indoor humidity reportedly drops to 37–40% during winter. We currently measure around 47% RH and haven't noticed any dryness.
Quotes:
Would you consider any of these repairs urgent based on the information/photos? I guess specifically, should the heat exchanger rust or burner condition be looked into further, or does this look more like preventative recommendations and optional upgrades? Would you get a second opinion before approving the ignition repair?
r/hvacadvice • u/watterson • 11h ago
I'm building out a soft story into livable space. We have a big I-beam above this wall that separates rooms, and need to run ducts somewhere. I'd like to avoid a soffit and came up with this idea to shorted the stud wall and run the duct along the top of it.
Is this dumb?
r/hvacadvice • u/No-Classic-9456 • 8h ago
Looking for input on hanging i went the 3/8 threaded rod and unistrut route since I have 14' ceilings and wanted it mounted at 9.5' . How ever not confident with the swaying it has. Is this the right path and do I need some sort of bracing and if so how thanks.
r/hvacadvice • u/CountryIcy2142 • 6h ago
r/hvacadvice • u/RichOnion8 • 5h ago
I am hearing noises on the walls of my rental, which looks like rats, I put a camera on my attic near the HVAC unit and I keep seeing this ghost like movements on my camera. Please tell me this is something else. I need to know this is something some of you can explain lol 😭
r/hvacadvice • u/Aardvark8606 • 6h ago
I just bought a new home, and I think I might have a roof leak in my bathroom after some rain this past week. I noticed some water leaking out of a wall mounted light fixture in the bathroom.
I’m not a handy person, but I wanted to take a look at how things looked in the attic space above that bathroom.
I popped my head in the attic, and I’m seeing that my HVAC unit is completely blocking access to the part of the attic that I need to get to. There doesn’t seem to be any clearance for me to climb over or around the HVAC unit.
Does anyone have any advice for how I can move past or over my HVAC unit?
Or is there something I can take apart from the HVAC to give me some clearance, and then reattach once I’m done looking? I wasn’t sure if I might be able to safely unscrew/untape the big duct in my 2nd picture
r/hvacadvice • u/xixxors • 9h ago
Hey all , I’ve been doing hvac for 3 years now and I’m at the point where it doesn’t matter what I’m called out for but I can diagnose the unit/ issue within 1hr of me showing up. I’m curious as to what my pay should look like ? I’m located in dfw and am making 1600 bi weekly as a certified tech and I feel like I’m getting shafted but I also don’t have a comparison to really go off of . I would appreciate any input on my situation and what my course of action should be.
r/hvacadvice • u/Connect_Buy_7466 • 10h ago
i started at 21$ an hour 4 months ago i got a raise of 24$ is that too little? this is CA norcal
r/hvacadvice • u/k4rupt • 3h ago
Hi all, my installer is stumped and I'm looking for ideas.
I have a Bryant Crossover inverter heat pump installed 6 weeks ago. Worked perfectly for the first 4 weeks.
Then it started short-cycling on cold mornings:
Only happens early morning when it's cold, around 43F. By late morning it's warm enough to run fine. Getting worse over time.
Techs found:
No leak code, no buzzing from the built-in leak detector.
What should I tell them to check? They can't reproduce it because they arrive after it warms up.
Edit: Outdoor is a Bryant 37MUHAQ60, indoor is a Bryant 45MUHAQ60 air handler, 5-ton, R-454B.
Thermostat is a 4th-gen Nest Learning Thermostat.
r/hvacadvice • u/Big-Raisin30 • 4h ago
UPDATE: I apparently cleaned the spark igniter and then also the flame sensor rod. The flames kicked on for about 45 seconds and then switched off again
I noticed that the air coming from the vents was not hot. This morning I checked the furnace and noticed the burner flames would kick on and then after a few seconds, kick back off. This evening I cleaned the flame sensor rod with a dollar bill and now notice that the burners aren’t igniting at all. Before I cleaned the rod, I didn’t check to see if the burners were still kicking on. The furnace was and currently is still running, just no flames. What should I do next? Please help.
1st pic - before cleaning rod
2nd pic - cleaned rod
3rd pic - reinserted rod
r/hvacadvice • u/Exact-Fee9117 • 4h ago
Are there any wizards out there that understand how exactly the Flame sensor signal is interpreted by the board on a typical gas pack? I’m already ordering a new replacement, however I see this occasionally in the field and have experience with basic board repairs and some component diag.
Gas valve is only opening for a couple seconds and going into ignition failure after 3 tries. Tested μADC through the harness and the spade on the board, got 5.2 on the meter so I ruled out the wire and rod
For reference the part number on this board is a Honeywell 1068-600
TLDR: Can you test/repair furnace control board flame rectification circuit when it is not reading the current from the flame rod?
r/hvacadvice • u/Aardvark8606 • 6h ago
I just bought a new home, and I think I might have a roof leak in my bathroom after some rain this past week. I noticed some water leaking out of a wall mounted light fixture in the bathroom.
I’m not a handy person, but I wanted to take a look at how things looked in the attic space above that bathroom.
I popped my head in the attic, and I’m seeing that my HVAC unit is completely blocking access to the part of the attic that I need to get to. There doesn’t seem to be any clearance for me to climb over or around the HVAC unit.
Does anyone have any advice for how I can move past or over my HVAC unit?
Or is there something I can take apart from the HVAC to give me some clearance, and then reattach once I’m done looking? I wasn’t sure if I might be able to safely unscrew/untape the big duct in my 2nd picture
r/hvacadvice • u/Utexas22 • 7h ago
Should this supply grille face upwards instead of down? Have several of these supplies on angled ceiling. Some rooms I’d like to be able to throw the air across the room rather than straight down. Although if if I switch orientation is just blowing directly on the ceiling.
Thoughts?
r/hvacadvice • u/nightpussy • 11h ago
First of all, deepest thank you to all the helpful and earnest responses I got here the other day. I always get a lot of anxiety when I post questions in reddit about house/handy stuff cause i have a lot to learn and sometimes people are very snarky, but this has been such a kind community so far.
Id love advice about my unit and next steps I should take. A technician came out today and said hes seen this problem on similar units (Ducane). He said it’s burning dirty (as many of you posited) and this can be a compounding problem that can get worse over time. The unit is from 2016, it was converted to propane in 2021.
The options are (1) replace the parts inside, which are under warranty potentially, though wouldn’t be done until beginning of january cause of a part needed. He said this is a gamble and it might do it again. The labor would likely be over 2k, replacing the unit
(2) consider replacing the unit, which an estimate be for measurements, etc was 11.5-12.5k
-could the technician be motivated to sell a unit and pushing me to replace?
-i still don’t fully understand why this is happening and why it could still keep doing it once parts are replaced?
-any recommendations on what i should do? Is it truly a gamble to go with just part replacements?
I am definitely not a rich person so advice is appreciated for what makes sense
r/hvacadvice • u/i_heart_indie • 22h ago
Hi all,
When flushing a hot water baseboard heating system, what’s the highest that the pressure gauge should go to?
I flushed it in the past without looking at the gauge because it was behind a cover that I couldn’t open, but I recently was able to open it. The pressure slowly rises, but goes pretty high. Is that normal?
I shut it off right before it reaches the limit of the pressure relief valve, but that leads to short bursts of flushing, which isn’t ideal.
i wish that I knew what the levels were in the past when I were doing it so that I can make a comparison for myself… ignorance truly is bliss.
Any info would be greatly appreciated.
Thanks in advance.
r/hvacadvice • u/brewyet • 3h ago
I know I’m going to get some comments about static pressure, but I’m trying to see ideas on a solution and I’ll be doing some measurements after I install it.
I have a 12”x6” register directly in the side of my duct (maybe 12x12 duct board trunk, I didn’t measure it exactly). It blows directly in the room. That room gets way colder and the downstream of the trunk never gets enough. When I close the register a bit to reduce the flow just a little it gets really loud in the room. The main duct is in between the ceiling joists of a 3-story house so I can’t add a damper anywhere.
Is there a different register I should try or do I need to cut a reducing plate with a hole and place it in the opening? Any ideas I’m not thinking of?
r/hvacadvice • u/PneumaticUnicorn • 6h ago
Seigler 51GKH UB-2, 45000 BTU
The pilot does not stay on, I replaced the thermocouple, and verified I'm getting about 28mV from the thermocouple.
I think the safety valve in the gas valve is bad, so looking to replace the valve. It's a very old unit so I can't find a direct replacement. Can anyone tell me if a newer model of gas valve will safely work for this unit? If so how do I determine what I type/model of valve I need to buy?
It's natural gas with a thermostat built into the valve
r/hvacadvice • u/oakhorizon • 7h ago
My partner is currently in school for HVAC and he’ll be certified next summer. I want to get him some tools for Christmas but I honestly have no idea what to get. What would you consider to be the most important tools to have going into the trade or what should he absolutely have to start with?
He’s got a good basic set of everyday tools from home and car repairs but nothing crazy. Would love to stay under $100-$150 since it wouldn’t be his only gift. Any advice or suggestions are much appreciated!
r/hvacadvice • u/Quacker-smacker98 • 7h ago
Hey,
I’m installing this new motor and hooking up the old duct work for a booster fan in a condo.
I had a non vented motor in there before and it was running super hot, salesman sold me the wrong one.
I now have a vented motor in there and it’s still running crazy hot. Almost too hot to touch.
Motor is pulling the correct amps at the panel bearings are fine it isn’t rubbing on anything.
Fan is just a squirrel cage fan, the base that mounts to the shaft is closed so it isn’t pushing a lot of air towards the motor.
Any ideas on how to cool it down?
Canada for reference.
r/hvacadvice • u/Any-Personality3312 • 7h ago
I’m not sure what flair to use!
My partner and I moved into a 13-year-old bungalow townhome in September and have recently noticed a lot of condensation build-up inside the window sills when running the heat/or having the windows closed. An internal thermostat reads 70% humidity (jumps to 80% after showering).
We have an HRV system (HRV 60H) that is running, but doesn’t seem to aid in any humidity aspect. We do not have other exhaust fans in our bathrooms or kitchen, only the HRV.
Heating is forced air gas.
We have a dehumidifier running in the interim to help with the humidity, but any ideas on where to begin? I have contacted a local HVAC company for duct cleaning and furnace servicing, but I am open to suggestions and tips!
Thanks in advance! :)
r/hvacadvice • u/This_Apartment_9138 • 8h ago
I replaced the relay attached to our breaker box last year with a unit from White Rodgers but it’s already dead, (still get 24v ac, but the baseboard heaters don’t turn off unless I ship off the breaker). It worked fine for a year.
Just wondering if I may have done something wrong, or just got a cheap or bad transformer? It seems crazy to only last a year of light use. I replaced the (very basic) thermostat to be certain. It must be shorted if heaters are on all the time, right?
Anyone have a recommendation for a high quality unit that will last for years?
r/hvacadvice • u/Bxtrmixer • 8h ago
New furnace and ac install, the condensation drain has some suction and blurps and chugs when the furnace runs. Once the cycle stops them it drains. Is this set up correct? Only a vent is on the AC.
r/hvacadvice • u/jssyvanilla01 • 9h ago
Started making this hissing sound and it would stop and start multiple times, ended up just shutting off the power to the unit. Heat pump unit